Cargando…

Continuous quality monitoring in the field: an evaluation of the performance of the Fio Deki Reader™ for rapid HIV testing in South Africa

BACKGROUND: Rapid diagnostic tests (RDTs) are a cornerstone of HIV diagnosis and rely on good quality processing and interpretation, particularly in the era of test and treat. The Deki Reader (Fio Corporation®, Toronto, Ontario, Canada) is a portable device designed specifically for analysing RDTs a...

Descripción completa

Detalles Bibliográficos
Autores principales: Noble, Lara, Scott, Lesley, Stewart-Isherwood, Lynsey, Molifi, Seponono John, Sanne, Ian, Da Silva, Pedro, Stevens, Wendy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7199324/
https://www.ncbi.nlm.nih.gov/pubmed/32366227
http://dx.doi.org/10.1186/s12879-020-4932-0
_version_ 1783529134961459200
author Noble, Lara
Scott, Lesley
Stewart-Isherwood, Lynsey
Molifi, Seponono John
Sanne, Ian
Da Silva, Pedro
Stevens, Wendy
author_facet Noble, Lara
Scott, Lesley
Stewart-Isherwood, Lynsey
Molifi, Seponono John
Sanne, Ian
Da Silva, Pedro
Stevens, Wendy
author_sort Noble, Lara
collection PubMed
description BACKGROUND: Rapid diagnostic tests (RDTs) are a cornerstone of HIV diagnosis and rely on good quality processing and interpretation, particularly in the era of test and treat. The Deki Reader (Fio Corporation®, Toronto, Ontario, Canada) is a portable device designed specifically for analysing RDTs and was selected for evaluation in South Africa in the context of HIV RDT analysis. METHODS: This study consisted of a laboratory evaluation and two-part field evaluation of the Deki Reader v100, covering two RDT testing algorithms, and an evaluation of the continuous quality monitoring through the Fionet™ web portal. Based on user feedback from the field evaluation, the device underwent hardware and software redesign, and the Deki Reader v200 was evaluated in the laboratory. Ethics approval for this evaluation was obtained from the University of the Witwatersrand Human Research Ethics Committee: M150160. RESULTS: The intra- and inter-device laboratory precision of the Deki Reader v100 were 98.3 and 99.2% respectively, and 99.3 and 100% for the Deki Reader v200. The laboratory concordances compared to standard-of-care reporting were 99.5 and 98.0% for the two respective models, while sensitivity and specificity were 99.5 and 99.4% for the Deki Reader V100 and 100 and 93.1% for the Deki Reader V200 respectively. Screening and confirmatory concordances in the field were 99.3 and 96.5% under algorithm 1 and 99.7 and 100% under algorithm 2. Sensitivity and specificity for the field evaluation were 99.8 and 97.7%. Overall robustness of the device was acceptable and continuous quality monitoring through Fionet™ was feasible. CONCLUSIONS: The Deki Reader provides an option for improved and reliable quality assessment for rapid diagnosis of HIV using RDTs to enhance the quality of healthcare at the point-of-care. However, the introduction of new RDTs and modification of current algorithms necessitates ongoing and agile RDT reader adjustments, which will require cost modelling to ensure sustainability of devices implemented into national HIV programs.
format Online
Article
Text
id pubmed-7199324
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-71993242020-05-08 Continuous quality monitoring in the field: an evaluation of the performance of the Fio Deki Reader™ for rapid HIV testing in South Africa Noble, Lara Scott, Lesley Stewart-Isherwood, Lynsey Molifi, Seponono John Sanne, Ian Da Silva, Pedro Stevens, Wendy BMC Infect Dis Research Article BACKGROUND: Rapid diagnostic tests (RDTs) are a cornerstone of HIV diagnosis and rely on good quality processing and interpretation, particularly in the era of test and treat. The Deki Reader (Fio Corporation®, Toronto, Ontario, Canada) is a portable device designed specifically for analysing RDTs and was selected for evaluation in South Africa in the context of HIV RDT analysis. METHODS: This study consisted of a laboratory evaluation and two-part field evaluation of the Deki Reader v100, covering two RDT testing algorithms, and an evaluation of the continuous quality monitoring through the Fionet™ web portal. Based on user feedback from the field evaluation, the device underwent hardware and software redesign, and the Deki Reader v200 was evaluated in the laboratory. Ethics approval for this evaluation was obtained from the University of the Witwatersrand Human Research Ethics Committee: M150160. RESULTS: The intra- and inter-device laboratory precision of the Deki Reader v100 were 98.3 and 99.2% respectively, and 99.3 and 100% for the Deki Reader v200. The laboratory concordances compared to standard-of-care reporting were 99.5 and 98.0% for the two respective models, while sensitivity and specificity were 99.5 and 99.4% for the Deki Reader V100 and 100 and 93.1% for the Deki Reader V200 respectively. Screening and confirmatory concordances in the field were 99.3 and 96.5% under algorithm 1 and 99.7 and 100% under algorithm 2. Sensitivity and specificity for the field evaluation were 99.8 and 97.7%. Overall robustness of the device was acceptable and continuous quality monitoring through Fionet™ was feasible. CONCLUSIONS: The Deki Reader provides an option for improved and reliable quality assessment for rapid diagnosis of HIV using RDTs to enhance the quality of healthcare at the point-of-care. However, the introduction of new RDTs and modification of current algorithms necessitates ongoing and agile RDT reader adjustments, which will require cost modelling to ensure sustainability of devices implemented into national HIV programs. BioMed Central 2020-05-04 /pmc/articles/PMC7199324/ /pubmed/32366227 http://dx.doi.org/10.1186/s12879-020-4932-0 Text en © The Author(s). 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Noble, Lara
Scott, Lesley
Stewart-Isherwood, Lynsey
Molifi, Seponono John
Sanne, Ian
Da Silva, Pedro
Stevens, Wendy
Continuous quality monitoring in the field: an evaluation of the performance of the Fio Deki Reader™ for rapid HIV testing in South Africa
title Continuous quality monitoring in the field: an evaluation of the performance of the Fio Deki Reader™ for rapid HIV testing in South Africa
title_full Continuous quality monitoring in the field: an evaluation of the performance of the Fio Deki Reader™ for rapid HIV testing in South Africa
title_fullStr Continuous quality monitoring in the field: an evaluation of the performance of the Fio Deki Reader™ for rapid HIV testing in South Africa
title_full_unstemmed Continuous quality monitoring in the field: an evaluation of the performance of the Fio Deki Reader™ for rapid HIV testing in South Africa
title_short Continuous quality monitoring in the field: an evaluation of the performance of the Fio Deki Reader™ for rapid HIV testing in South Africa
title_sort continuous quality monitoring in the field: an evaluation of the performance of the fio deki reader™ for rapid hiv testing in south africa
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7199324/
https://www.ncbi.nlm.nih.gov/pubmed/32366227
http://dx.doi.org/10.1186/s12879-020-4932-0
work_keys_str_mv AT noblelara continuousqualitymonitoringinthefieldanevaluationoftheperformanceofthefiodekireaderforrapidhivtestinginsouthafrica
AT scottlesley continuousqualitymonitoringinthefieldanevaluationoftheperformanceofthefiodekireaderforrapidhivtestinginsouthafrica
AT stewartisherwoodlynsey continuousqualitymonitoringinthefieldanevaluationoftheperformanceofthefiodekireaderforrapidhivtestinginsouthafrica
AT molifisepononojohn continuousqualitymonitoringinthefieldanevaluationoftheperformanceofthefiodekireaderforrapidhivtestinginsouthafrica
AT sanneian continuousqualitymonitoringinthefieldanevaluationoftheperformanceofthefiodekireaderforrapidhivtestinginsouthafrica
AT dasilvapedro continuousqualitymonitoringinthefieldanevaluationoftheperformanceofthefiodekireaderforrapidhivtestinginsouthafrica
AT stevenswendy continuousqualitymonitoringinthefieldanevaluationoftheperformanceofthefiodekireaderforrapidhivtestinginsouthafrica