Three-year follow-up of changes of cortical bone thickness after implantation of Endo-Exo-Prosthesis (EEP) for transfemoral amputees

INTRODUCTION: Transcutaneous Osseointegrated Prosthetic Systems (TOPS) offer a good alternative for patients who cannot be satisfactorily rehabilitated by conventional suspension sockets. The Endo-Exo-Prothesis (EEP, ESKA Orthopaedic Handels GmbH®, Deutschland) is the most implanted TOPS in Germany....

Descripción completa

Detalles Bibliográficos
Autores principales: Örgel, Marcus, Liodakis, Emmanouil, Jaratjitwilai, Pratya, Harb, Afif, Wirries, Nils, Omar, Mohamed, Krettek, Christian, Aschoff, Horst-Heinrich
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7199357/
https://www.ncbi.nlm.nih.gov/pubmed/32366315
http://dx.doi.org/10.1186/s13018-020-01675-w
_version_ 1783529142399008768
author Örgel, Marcus
Liodakis, Emmanouil
Jaratjitwilai, Pratya
Harb, Afif
Wirries, Nils
Omar, Mohamed
Krettek, Christian
Aschoff, Horst-Heinrich
author_facet Örgel, Marcus
Liodakis, Emmanouil
Jaratjitwilai, Pratya
Harb, Afif
Wirries, Nils
Omar, Mohamed
Krettek, Christian
Aschoff, Horst-Heinrich
author_sort Örgel, Marcus
collection PubMed
description INTRODUCTION: Transcutaneous Osseointegrated Prosthetic Systems (TOPS) offer a good alternative for patients who cannot be satisfactorily rehabilitated by conventional suspension sockets. The Endo-Exo-Prothesis (EEP, ESKA Orthopaedic Handels GmbH®, Deutschland) is the most implanted TOPS in Germany. Previous studies have shown that cortical thickness increases after implantation of TOPS. The aim of this study is to determine changes of cortical thickness in relation to the time after implantation of the Endo-Fix-Stem. PATIENTS AND METHODS: All transfemoral amputees treated by EEP from 2007 to 2013 were operated by the last author of this study. X-ray images of 4 follow-up intervals (postoperative, 3 months, 12 months, 3 years) were analyzed retrospectively. The femoral residuum was divided into 3 sections (proximal, middle, distal) with 2 measuring points in each section: medial and lateral. Cortical thickness was measured at these 6 points and compared at regular intervals using the Friedman test for non-parametric dependent variables. RESULTS: Thirty-seven patients with 40 implants were included. The average age was 52.2 years (30–79 years). 83.7% of the patients were male. No statistical significance could be shown for any of the measuring points of the femoral residual (proximal medial, proximal lateral, middle medial, middle lateral, distal medial, distal lateral) among the mean values of the cortical thickness at the different follow-up times (p > 0.05 for all measuring points). Cortical remodeling processes (> 1 millimeter (mm)) occurred in all implants despite a missing statistical significance. Hypertrophy could be confirmed for 42.5% and atrophy for 37.5%. Twenty percent of the cases showed a parallel occurrence of both entities. Cortical changes greater than 5 mm were only observed at the distal end of the femur. CONCLUSION: Even if our results did not show any significant difference, it can be deduced that the osseointegration process leads to a remodeling of the bone structure, both in terms of increased bone formation and bone resorption. However, it has not yet been conclusively clarified which processes lead to hyper- or atrophy. The force transmission between prosthesis and bone and the facultative bacterial colonization of the stoma are still the main factors which may be responsible for the bone remodeling processes.
format Online
Article
Text
id pubmed-7199357
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-71993572020-05-08 Three-year follow-up of changes of cortical bone thickness after implantation of Endo-Exo-Prosthesis (EEP) for transfemoral amputees Örgel, Marcus Liodakis, Emmanouil Jaratjitwilai, Pratya Harb, Afif Wirries, Nils Omar, Mohamed Krettek, Christian Aschoff, Horst-Heinrich J Orthop Surg Res Research Article INTRODUCTION: Transcutaneous Osseointegrated Prosthetic Systems (TOPS) offer a good alternative for patients who cannot be satisfactorily rehabilitated by conventional suspension sockets. The Endo-Exo-Prothesis (EEP, ESKA Orthopaedic Handels GmbH®, Deutschland) is the most implanted TOPS in Germany. Previous studies have shown that cortical thickness increases after implantation of TOPS. The aim of this study is to determine changes of cortical thickness in relation to the time after implantation of the Endo-Fix-Stem. PATIENTS AND METHODS: All transfemoral amputees treated by EEP from 2007 to 2013 were operated by the last author of this study. X-ray images of 4 follow-up intervals (postoperative, 3 months, 12 months, 3 years) were analyzed retrospectively. The femoral residuum was divided into 3 sections (proximal, middle, distal) with 2 measuring points in each section: medial and lateral. Cortical thickness was measured at these 6 points and compared at regular intervals using the Friedman test for non-parametric dependent variables. RESULTS: Thirty-seven patients with 40 implants were included. The average age was 52.2 years (30–79 years). 83.7% of the patients were male. No statistical significance could be shown for any of the measuring points of the femoral residual (proximal medial, proximal lateral, middle medial, middle lateral, distal medial, distal lateral) among the mean values of the cortical thickness at the different follow-up times (p > 0.05 for all measuring points). Cortical remodeling processes (> 1 millimeter (mm)) occurred in all implants despite a missing statistical significance. Hypertrophy could be confirmed for 42.5% and atrophy for 37.5%. Twenty percent of the cases showed a parallel occurrence of both entities. Cortical changes greater than 5 mm were only observed at the distal end of the femur. CONCLUSION: Even if our results did not show any significant difference, it can be deduced that the osseointegration process leads to a remodeling of the bone structure, both in terms of increased bone formation and bone resorption. However, it has not yet been conclusively clarified which processes lead to hyper- or atrophy. The force transmission between prosthesis and bone and the facultative bacterial colonization of the stoma are still the main factors which may be responsible for the bone remodeling processes. BioMed Central 2020-05-04 /pmc/articles/PMC7199357/ /pubmed/32366315 http://dx.doi.org/10.1186/s13018-020-01675-w Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Örgel, Marcus
Liodakis, Emmanouil
Jaratjitwilai, Pratya
Harb, Afif
Wirries, Nils
Omar, Mohamed
Krettek, Christian
Aschoff, Horst-Heinrich
Three-year follow-up of changes of cortical bone thickness after implantation of Endo-Exo-Prosthesis (EEP) for transfemoral amputees
title Three-year follow-up of changes of cortical bone thickness after implantation of Endo-Exo-Prosthesis (EEP) for transfemoral amputees
title_full Three-year follow-up of changes of cortical bone thickness after implantation of Endo-Exo-Prosthesis (EEP) for transfemoral amputees
title_fullStr Three-year follow-up of changes of cortical bone thickness after implantation of Endo-Exo-Prosthesis (EEP) for transfemoral amputees
title_full_unstemmed Three-year follow-up of changes of cortical bone thickness after implantation of Endo-Exo-Prosthesis (EEP) for transfemoral amputees
title_short Three-year follow-up of changes of cortical bone thickness after implantation of Endo-Exo-Prosthesis (EEP) for transfemoral amputees
title_sort three-year follow-up of changes of cortical bone thickness after implantation of endo-exo-prosthesis (eep) for transfemoral amputees
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7199357/
https://www.ncbi.nlm.nih.gov/pubmed/32366315
http://dx.doi.org/10.1186/s13018-020-01675-w
work_keys_str_mv AT orgelmarcus threeyearfollowupofchangesofcorticalbonethicknessafterimplantationofendoexoprosthesiseepfortransfemoralamputees
AT liodakisemmanouil threeyearfollowupofchangesofcorticalbonethicknessafterimplantationofendoexoprosthesiseepfortransfemoralamputees
AT jaratjitwilaipratya threeyearfollowupofchangesofcorticalbonethicknessafterimplantationofendoexoprosthesiseepfortransfemoralamputees
AT harbafif threeyearfollowupofchangesofcorticalbonethicknessafterimplantationofendoexoprosthesiseepfortransfemoralamputees
AT wirriesnils threeyearfollowupofchangesofcorticalbonethicknessafterimplantationofendoexoprosthesiseepfortransfemoralamputees
AT omarmohamed threeyearfollowupofchangesofcorticalbonethicknessafterimplantationofendoexoprosthesiseepfortransfemoralamputees
AT krettekchristian threeyearfollowupofchangesofcorticalbonethicknessafterimplantationofendoexoprosthesiseepfortransfemoralamputees
AT aschoffhorstheinrich threeyearfollowupofchangesofcorticalbonethicknessafterimplantationofendoexoprosthesiseepfortransfemoralamputees