Cargando…

The Effect of Real-time Headbox Adjustments on Data Quality

Following a patent owned by Tobii, the framerate of a CMOS camera can be increased by reducing the size of the recording window so that it fits the eyes with minimum room to spare. The position of the recording window can be dynamically adjusted within the camera sensor area to follow the eyes as th...

Descripción completa

Detalles Bibliográficos
Autor principal: Blignaut, Pieter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bern Open Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7200168/
https://www.ncbi.nlm.nih.gov/pubmed/33828680
http://dx.doi.org/10.16910/jemr.11.1.4
_version_ 1783529281456963584
author Blignaut, Pieter
author_facet Blignaut, Pieter
author_sort Blignaut, Pieter
collection PubMed
description Following a patent owned by Tobii, the framerate of a CMOS camera can be increased by reducing the size of the recording window so that it fits the eyes with minimum room to spare. The position of the recording window can be dynamically adjusted within the camera sensor area to follow the eyes as the participant moves the head. Since only a portion of the camera sensor data is communicated to the computer and processed, much higher framerates can be achieved with the same CPU and camera. Eye trackers can be expected to present data at a high speed, with good accuracy and precision, small latency and with minimal loss of data while allowing participants to behave as normally as possible. In this study, the effect of headbox adjustments in real-time is investigated with respect to the above-mentioned parameters. It was found that, for the specific camera model and tracking algorithm, one or two headbox adjustments per second, as would normally be the case during recording of human participants, could be tolerated in favour of a higher framerate. The effect of adjustment of the recording window can be reduced by using a larger recording window at the cost of the framerate.
format Online
Article
Text
id pubmed-7200168
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Bern Open Publishing
record_format MEDLINE/PubMed
spelling pubmed-72001682021-04-06 The Effect of Real-time Headbox Adjustments on Data Quality Blignaut, Pieter J Eye Mov Res Research Article Following a patent owned by Tobii, the framerate of a CMOS camera can be increased by reducing the size of the recording window so that it fits the eyes with minimum room to spare. The position of the recording window can be dynamically adjusted within the camera sensor area to follow the eyes as the participant moves the head. Since only a portion of the camera sensor data is communicated to the computer and processed, much higher framerates can be achieved with the same CPU and camera. Eye trackers can be expected to present data at a high speed, with good accuracy and precision, small latency and with minimal loss of data while allowing participants to behave as normally as possible. In this study, the effect of headbox adjustments in real-time is investigated with respect to the above-mentioned parameters. It was found that, for the specific camera model and tracking algorithm, one or two headbox adjustments per second, as would normally be the case during recording of human participants, could be tolerated in favour of a higher framerate. The effect of adjustment of the recording window can be reduced by using a larger recording window at the cost of the framerate. Bern Open Publishing 2018-03-21 /pmc/articles/PMC7200168/ /pubmed/33828680 http://dx.doi.org/10.16910/jemr.11.1.4 Text en This work is licensed under a Creative Commons Attribution 4.0 International License, ( https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use and redistribution provided that the original author and source are credited.
spellingShingle Research Article
Blignaut, Pieter
The Effect of Real-time Headbox Adjustments on Data Quality
title The Effect of Real-time Headbox Adjustments on Data Quality
title_full The Effect of Real-time Headbox Adjustments on Data Quality
title_fullStr The Effect of Real-time Headbox Adjustments on Data Quality
title_full_unstemmed The Effect of Real-time Headbox Adjustments on Data Quality
title_short The Effect of Real-time Headbox Adjustments on Data Quality
title_sort effect of real-time headbox adjustments on data quality
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7200168/
https://www.ncbi.nlm.nih.gov/pubmed/33828680
http://dx.doi.org/10.16910/jemr.11.1.4
work_keys_str_mv AT blignautpieter theeffectofrealtimeheadboxadjustmentsondataquality
AT blignautpieter effectofrealtimeheadboxadjustmentsondataquality