Use of Smart Technology for the Early Diagnosis of Complications After Cardiac Surgery: The Box 2.0 Study Protocol
BACKGROUND: Atrial fibrillation (AF), sternal wound infection, and cardiac decompensation are complications that can occur after cardiac surgery. Early detection of these complications is clinically relevant, as early treatment is associated with better clinical outcomes. Remote monitoring with the...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7201318/ https://www.ncbi.nlm.nih.gov/pubmed/32314974 http://dx.doi.org/10.2196/16326 |
_version_ | 1783529521423581184 |
---|---|
author | Biersteker, Tom E Boogers, Mark J de Lind van Wijngaarden, Robert AF Groenwold, Rolf HH Trines, Serge A van Alem, Anouk P Kirchhof, Charles JHJ van Hof, Nicolette Klautz, Robert JM Schalij, Martin J Treskes, Roderick W |
author_facet | Biersteker, Tom E Boogers, Mark J de Lind van Wijngaarden, Robert AF Groenwold, Rolf HH Trines, Serge A van Alem, Anouk P Kirchhof, Charles JHJ van Hof, Nicolette Klautz, Robert JM Schalij, Martin J Treskes, Roderick W |
author_sort | Biersteker, Tom E |
collection | PubMed |
description | BACKGROUND: Atrial fibrillation (AF), sternal wound infection, and cardiac decompensation are complications that can occur after cardiac surgery. Early detection of these complications is clinically relevant, as early treatment is associated with better clinical outcomes. Remote monitoring with the use of a smartphone (mobile health [mHealth]) might improve the early detection of complications after cardiac surgery. OBJECTIVE: The primary aim of this study is to compare the detection rate of AF diagnosed with an mHealth solution to the detection rate of AF diagnosed with standard care. Secondary objectives include detection of sternal wound infection and cardiac decompensation, as well as assessment of quality of life, patient satisfaction, and cost-effectiveness. METHODS: The Box 2.0 is a study with a prospective intervention group and a historical control group for comparison. Patients undergoing cardiac surgery at Leiden University Medical Center are eligible for enrollment. In this study, 365 historical patients will be used as controls and 365 other participants will be asked to receive either The Box 2.0 intervention consisting of seven home measurement devices along with a video consultation 2 weeks after discharge or standard cardiac care for 3 months. Patient information will be analyzed according to the intention-to-treat principle. The Box 2.0 devices include a blood pressure monitor, thermometer, weight scale, step count watch, single-lead electrocardiogram (ECG) device, 12-lead ECG device, and pulse oximeter. RESULTS: The study started in November 2018. The primary outcome of this study is the detection rate of AF in both groups. Quality of life is measured with the five-level EuroQol five-dimension (EQ-5D-5L) questionnaire. Cost-effectiveness is calculated from a society perspective using prices from Dutch costing guidelines and quality of life data from the study. In the historical cohort, 93.9% (336/358) completed the EQ-5D-5L and patient satisfaction questionnaires 3 months after cardiac surgery. CONCLUSIONS: The rationale and design of a study to investigate mHealth devices in postoperative cardiac surgery patients are presented. The first results are expected in September 2020. TRIAL REGISTRATION: ClinicalTrials.gov NCT03690492; http://clinicaltrials.gov/show/NCT03690492 INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/16326 |
format | Online Article Text |
id | pubmed-7201318 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-72013182020-05-08 Use of Smart Technology for the Early Diagnosis of Complications After Cardiac Surgery: The Box 2.0 Study Protocol Biersteker, Tom E Boogers, Mark J de Lind van Wijngaarden, Robert AF Groenwold, Rolf HH Trines, Serge A van Alem, Anouk P Kirchhof, Charles JHJ van Hof, Nicolette Klautz, Robert JM Schalij, Martin J Treskes, Roderick W JMIR Res Protoc Protocol BACKGROUND: Atrial fibrillation (AF), sternal wound infection, and cardiac decompensation are complications that can occur after cardiac surgery. Early detection of these complications is clinically relevant, as early treatment is associated with better clinical outcomes. Remote monitoring with the use of a smartphone (mobile health [mHealth]) might improve the early detection of complications after cardiac surgery. OBJECTIVE: The primary aim of this study is to compare the detection rate of AF diagnosed with an mHealth solution to the detection rate of AF diagnosed with standard care. Secondary objectives include detection of sternal wound infection and cardiac decompensation, as well as assessment of quality of life, patient satisfaction, and cost-effectiveness. METHODS: The Box 2.0 is a study with a prospective intervention group and a historical control group for comparison. Patients undergoing cardiac surgery at Leiden University Medical Center are eligible for enrollment. In this study, 365 historical patients will be used as controls and 365 other participants will be asked to receive either The Box 2.0 intervention consisting of seven home measurement devices along with a video consultation 2 weeks after discharge or standard cardiac care for 3 months. Patient information will be analyzed according to the intention-to-treat principle. The Box 2.0 devices include a blood pressure monitor, thermometer, weight scale, step count watch, single-lead electrocardiogram (ECG) device, 12-lead ECG device, and pulse oximeter. RESULTS: The study started in November 2018. The primary outcome of this study is the detection rate of AF in both groups. Quality of life is measured with the five-level EuroQol five-dimension (EQ-5D-5L) questionnaire. Cost-effectiveness is calculated from a society perspective using prices from Dutch costing guidelines and quality of life data from the study. In the historical cohort, 93.9% (336/358) completed the EQ-5D-5L and patient satisfaction questionnaires 3 months after cardiac surgery. CONCLUSIONS: The rationale and design of a study to investigate mHealth devices in postoperative cardiac surgery patients are presented. The first results are expected in September 2020. TRIAL REGISTRATION: ClinicalTrials.gov NCT03690492; http://clinicaltrials.gov/show/NCT03690492 INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/16326 JMIR Publications 2020-04-21 /pmc/articles/PMC7201318/ /pubmed/32314974 http://dx.doi.org/10.2196/16326 Text en ©Tom E Biersteker, Mark J Boogers, Robert AF de Lind van Wijngaarden, Rolf HH Groenwold, Serge A Trines, Anouk P van Alem, Charles JHJ Kirchhof, Nicolette van Hof, Robert JM Klautz, Martin J Schalij, Roderick W Treskes. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 21.04.2020. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Research Protocols, is properly cited. The complete bibliographic information, a link to the original publication on http://www.researchprotocols.org, as well as this copyright and license information must be included. |
spellingShingle | Protocol Biersteker, Tom E Boogers, Mark J de Lind van Wijngaarden, Robert AF Groenwold, Rolf HH Trines, Serge A van Alem, Anouk P Kirchhof, Charles JHJ van Hof, Nicolette Klautz, Robert JM Schalij, Martin J Treskes, Roderick W Use of Smart Technology for the Early Diagnosis of Complications After Cardiac Surgery: The Box 2.0 Study Protocol |
title | Use of Smart Technology for the Early Diagnosis of Complications After Cardiac Surgery: The Box 2.0 Study Protocol |
title_full | Use of Smart Technology for the Early Diagnosis of Complications After Cardiac Surgery: The Box 2.0 Study Protocol |
title_fullStr | Use of Smart Technology for the Early Diagnosis of Complications After Cardiac Surgery: The Box 2.0 Study Protocol |
title_full_unstemmed | Use of Smart Technology for the Early Diagnosis of Complications After Cardiac Surgery: The Box 2.0 Study Protocol |
title_short | Use of Smart Technology for the Early Diagnosis of Complications After Cardiac Surgery: The Box 2.0 Study Protocol |
title_sort | use of smart technology for the early diagnosis of complications after cardiac surgery: the box 2.0 study protocol |
topic | Protocol |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7201318/ https://www.ncbi.nlm.nih.gov/pubmed/32314974 http://dx.doi.org/10.2196/16326 |
work_keys_str_mv | AT bierstekertome useofsmarttechnologyfortheearlydiagnosisofcomplicationsaftercardiacsurgerythebox20studyprotocol AT boogersmarkj useofsmarttechnologyfortheearlydiagnosisofcomplicationsaftercardiacsurgerythebox20studyprotocol AT delindvanwijngaardenrobertaf useofsmarttechnologyfortheearlydiagnosisofcomplicationsaftercardiacsurgerythebox20studyprotocol AT groenwoldrolfhh useofsmarttechnologyfortheearlydiagnosisofcomplicationsaftercardiacsurgerythebox20studyprotocol AT trinessergea useofsmarttechnologyfortheearlydiagnosisofcomplicationsaftercardiacsurgerythebox20studyprotocol AT vanalemanoukp useofsmarttechnologyfortheearlydiagnosisofcomplicationsaftercardiacsurgerythebox20studyprotocol AT kirchhofcharlesjhj useofsmarttechnologyfortheearlydiagnosisofcomplicationsaftercardiacsurgerythebox20studyprotocol AT vanhofnicolette useofsmarttechnologyfortheearlydiagnosisofcomplicationsaftercardiacsurgerythebox20studyprotocol AT klautzrobertjm useofsmarttechnologyfortheearlydiagnosisofcomplicationsaftercardiacsurgerythebox20studyprotocol AT schalijmartinj useofsmarttechnologyfortheearlydiagnosisofcomplicationsaftercardiacsurgerythebox20studyprotocol AT treskesroderickw useofsmarttechnologyfortheearlydiagnosisofcomplicationsaftercardiacsurgerythebox20studyprotocol |