Cargando…

Comparison of three dimensional reconstruction and conventional computer tomography angiography in patients undergoing zero-ischemia laparoscopic partial nephrectomy

BACKGROUND: With the development of three dimensional (3D) reconstruction and printing technology, it has been widely using in the field of urology. However, there have been few studies reporting the role of 3D reconstruction in zero-ischemia partial nephrectomy (PN). The aim of this study was to as...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Xiaorong, Jiang, Chen, Wu, Guangyu, Shen, Chao, Fu, Qibo, Chen, Yonghui, Liu, Dongming, Xue, Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7201555/
https://www.ncbi.nlm.nih.gov/pubmed/32375663
http://dx.doi.org/10.1186/s12880-020-00445-8
_version_ 1783529558245376000
author Wu, Xiaorong
Jiang, Chen
Wu, Guangyu
Shen, Chao
Fu, Qibo
Chen, Yonghui
Liu, Dongming
Xue, Wei
author_facet Wu, Xiaorong
Jiang, Chen
Wu, Guangyu
Shen, Chao
Fu, Qibo
Chen, Yonghui
Liu, Dongming
Xue, Wei
author_sort Wu, Xiaorong
collection PubMed
description BACKGROUND: With the development of three dimensional (3D) reconstruction and printing technology, it has been widely using in the field of urology. However, there have been few studies reporting the role of 3D reconstruction in zero-ischemia partial nephrectomy (PN). The aim of this study was to assess the role of 3D reconstruction and conventional computer tomography angiography (CTA) in zero-ischemia laparoscopic partial nephrectomy (LPN). METHODS: A total of 60 consecutive patients undergoing zero-ischemia LPN between October 2017 and March 2018 who underwent CTA (CTA group including 30 patients) and 3D reconstruction (3D group including the remaining 30 patients) preoperatively were included. 3D reconstruction and CTA images were prepared which were used to demonstrate the number and spatial interrelationships of the location of renal tumors and tumor feeding arteries. These radiological findings were directly correlated with intraoperative surgical findings at laparoscopy. Baseline, perioperative variables and the rate of accurate tumor feeding artery orientation were compared between groups. RESULTS: All LPNs were completed without conversion to renal hilar clamping or open surgery. Preoperative 3D reconstruction identified that 15 patients had only one tumor feeding artery, 12 had two, and another 3 had three, while the conventional CTA revealed that 22 patients had one tumor feeding artery, 8 had two (P > 0.05). The mean operation time was shorter and estimated blood loss was less in the 3D group (P < 0.05) and the rate of accurate tumor feeding artery dissection was higher in the 3D group (91.7%) in comparison with the CTA group (84.2%). The baseline characteristics and renal function outcomes had no statistical differences between groups. CONCLUSIONS: 3D reconstruction can provide comprehensive information for the preoperative evaluation and intraoperative orientation about tumor feeding arteries that may facilitate tumor resection during zero-ischemia LPN for renal tumors.
format Online
Article
Text
id pubmed-7201555
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-72015552020-05-08 Comparison of three dimensional reconstruction and conventional computer tomography angiography in patients undergoing zero-ischemia laparoscopic partial nephrectomy Wu, Xiaorong Jiang, Chen Wu, Guangyu Shen, Chao Fu, Qibo Chen, Yonghui Liu, Dongming Xue, Wei BMC Med Imaging Research Article BACKGROUND: With the development of three dimensional (3D) reconstruction and printing technology, it has been widely using in the field of urology. However, there have been few studies reporting the role of 3D reconstruction in zero-ischemia partial nephrectomy (PN). The aim of this study was to assess the role of 3D reconstruction and conventional computer tomography angiography (CTA) in zero-ischemia laparoscopic partial nephrectomy (LPN). METHODS: A total of 60 consecutive patients undergoing zero-ischemia LPN between October 2017 and March 2018 who underwent CTA (CTA group including 30 patients) and 3D reconstruction (3D group including the remaining 30 patients) preoperatively were included. 3D reconstruction and CTA images were prepared which were used to demonstrate the number and spatial interrelationships of the location of renal tumors and tumor feeding arteries. These radiological findings were directly correlated with intraoperative surgical findings at laparoscopy. Baseline, perioperative variables and the rate of accurate tumor feeding artery orientation were compared between groups. RESULTS: All LPNs were completed without conversion to renal hilar clamping or open surgery. Preoperative 3D reconstruction identified that 15 patients had only one tumor feeding artery, 12 had two, and another 3 had three, while the conventional CTA revealed that 22 patients had one tumor feeding artery, 8 had two (P > 0.05). The mean operation time was shorter and estimated blood loss was less in the 3D group (P < 0.05) and the rate of accurate tumor feeding artery dissection was higher in the 3D group (91.7%) in comparison with the CTA group (84.2%). The baseline characteristics and renal function outcomes had no statistical differences between groups. CONCLUSIONS: 3D reconstruction can provide comprehensive information for the preoperative evaluation and intraoperative orientation about tumor feeding arteries that may facilitate tumor resection during zero-ischemia LPN for renal tumors. BioMed Central 2020-05-06 /pmc/articles/PMC7201555/ /pubmed/32375663 http://dx.doi.org/10.1186/s12880-020-00445-8 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Wu, Xiaorong
Jiang, Chen
Wu, Guangyu
Shen, Chao
Fu, Qibo
Chen, Yonghui
Liu, Dongming
Xue, Wei
Comparison of three dimensional reconstruction and conventional computer tomography angiography in patients undergoing zero-ischemia laparoscopic partial nephrectomy
title Comparison of three dimensional reconstruction and conventional computer tomography angiography in patients undergoing zero-ischemia laparoscopic partial nephrectomy
title_full Comparison of three dimensional reconstruction and conventional computer tomography angiography in patients undergoing zero-ischemia laparoscopic partial nephrectomy
title_fullStr Comparison of three dimensional reconstruction and conventional computer tomography angiography in patients undergoing zero-ischemia laparoscopic partial nephrectomy
title_full_unstemmed Comparison of three dimensional reconstruction and conventional computer tomography angiography in patients undergoing zero-ischemia laparoscopic partial nephrectomy
title_short Comparison of three dimensional reconstruction and conventional computer tomography angiography in patients undergoing zero-ischemia laparoscopic partial nephrectomy
title_sort comparison of three dimensional reconstruction and conventional computer tomography angiography in patients undergoing zero-ischemia laparoscopic partial nephrectomy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7201555/
https://www.ncbi.nlm.nih.gov/pubmed/32375663
http://dx.doi.org/10.1186/s12880-020-00445-8
work_keys_str_mv AT wuxiaorong comparisonofthreedimensionalreconstructionandconventionalcomputertomographyangiographyinpatientsundergoingzeroischemialaparoscopicpartialnephrectomy
AT jiangchen comparisonofthreedimensionalreconstructionandconventionalcomputertomographyangiographyinpatientsundergoingzeroischemialaparoscopicpartialnephrectomy
AT wuguangyu comparisonofthreedimensionalreconstructionandconventionalcomputertomographyangiographyinpatientsundergoingzeroischemialaparoscopicpartialnephrectomy
AT shenchao comparisonofthreedimensionalreconstructionandconventionalcomputertomographyangiographyinpatientsundergoingzeroischemialaparoscopicpartialnephrectomy
AT fuqibo comparisonofthreedimensionalreconstructionandconventionalcomputertomographyangiographyinpatientsundergoingzeroischemialaparoscopicpartialnephrectomy
AT chenyonghui comparisonofthreedimensionalreconstructionandconventionalcomputertomographyangiographyinpatientsundergoingzeroischemialaparoscopicpartialnephrectomy
AT liudongming comparisonofthreedimensionalreconstructionandconventionalcomputertomographyangiographyinpatientsundergoingzeroischemialaparoscopicpartialnephrectomy
AT xuewei comparisonofthreedimensionalreconstructionandconventionalcomputertomographyangiographyinpatientsundergoingzeroischemialaparoscopicpartialnephrectomy