Cargando…
Accurate HIV viral load measurement in primary health care settings using the cobas(®) plasma separation card
INTRODUCTION: Plasma is considered the gold standard for HIV viral load (VL) testing, however its use is challenging due to the need for phlebotomy and centrifugation services, as well as cold chain for transporting to laboratories for testing. The use of Dried Blood Spot (DBS) specimen has allowed...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7202605/ https://www.ncbi.nlm.nih.gov/pubmed/32374748 http://dx.doi.org/10.1371/journal.pone.0232122 |
_version_ | 1783529731758489600 |
---|---|
author | Vubil, Adolfo Zicai, Ana Flora Sitoe, Nádia Nhachigule, Carina Meggi, Bindiya Loquiha, Osvaldo Viegas, Sofia Mabunda, Nédio Scott, Lesley Jani, Ilesh |
author_facet | Vubil, Adolfo Zicai, Ana Flora Sitoe, Nádia Nhachigule, Carina Meggi, Bindiya Loquiha, Osvaldo Viegas, Sofia Mabunda, Nédio Scott, Lesley Jani, Ilesh |
author_sort | Vubil, Adolfo |
collection | PubMed |
description | INTRODUCTION: Plasma is considered the gold standard for HIV viral load (VL) testing, however its use is challenging due to the need for phlebotomy and centrifugation services, as well as cold chain for transporting to laboratories for testing. The use of Dried Blood Spot (DBS) specimen has allowed a rapid expansion of antiretroviral therapy (ART) monitoring in remote areas in many African countries, however, the VL in DBS may overestimate the copies of viral RNA result at the clinically relevant range of 1000 copies/ml, due to proviral DNA and intracellular RNA. The characteristics of the cobas(®) Plasma Separation Card (PSC) specimen are similar to fresh plasma (gold standard), so a better performance of HIV VL is expetected in PSC specimen and can be an alternative to DBS. This study aims to evaluate the performance of cobas(®) PSC for VL testing at primary health care facilities in Mozambique. METHODOLOGY: HIV-1 infected adults on ART were enrolled consecutively in two health facilities in Mozambique, between August 2018 and October 2018. Capillary and venous cobas(®) PSC, DBS and fresh plasma specimens were collected from each patient. All specimens were tested for VL using CAP/CTM v2.0. Sensitivity and specificity of viral load using DBS, capillary and venous PSC specimens were estimated. Viral load obtained in fresh plasma specimen was used as reference and a threshold of 1000 copies/ml was considered for the analyses. RESULTS: From the total 613 patients included for the study, 2444 specimens including DBS (613), plasma (613), venous cobas(®) PSC (609) and capillary cobas(®) PSC (609) were collected and 2407 results were obtained. Sensitivity and specificity of the VL using venous cobas(®)PSC specimen at 1000 copies/ml threshold were 99.8% and 98.1% respectively, whereas for capillary cobas(®) PSC sensitivity was 99.6% and specificity was 97.2%. For DBS VL, sensitivity was 96.9% and specificity was 81.8%. Misclassification rate was more prominent in DBS specimens (5.9%), but lower in venous and capillary cobas(®)PSC with a rate of 0.3% and 0.7% respectively. CONCLUSION: The cobas(®) PSC specimen has improved performance over DBS for more accurate VL testing aligned with plasma testing. The use of this specimen type can increase the rates of reliable VL results and this will improve the quality of VL monitoring of HIV-positive patients in low-income settings. |
format | Online Article Text |
id | pubmed-7202605 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-72026052020-05-12 Accurate HIV viral load measurement in primary health care settings using the cobas(®) plasma separation card Vubil, Adolfo Zicai, Ana Flora Sitoe, Nádia Nhachigule, Carina Meggi, Bindiya Loquiha, Osvaldo Viegas, Sofia Mabunda, Nédio Scott, Lesley Jani, Ilesh PLoS One Research Article INTRODUCTION: Plasma is considered the gold standard for HIV viral load (VL) testing, however its use is challenging due to the need for phlebotomy and centrifugation services, as well as cold chain for transporting to laboratories for testing. The use of Dried Blood Spot (DBS) specimen has allowed a rapid expansion of antiretroviral therapy (ART) monitoring in remote areas in many African countries, however, the VL in DBS may overestimate the copies of viral RNA result at the clinically relevant range of 1000 copies/ml, due to proviral DNA and intracellular RNA. The characteristics of the cobas(®) Plasma Separation Card (PSC) specimen are similar to fresh plasma (gold standard), so a better performance of HIV VL is expetected in PSC specimen and can be an alternative to DBS. This study aims to evaluate the performance of cobas(®) PSC for VL testing at primary health care facilities in Mozambique. METHODOLOGY: HIV-1 infected adults on ART were enrolled consecutively in two health facilities in Mozambique, between August 2018 and October 2018. Capillary and venous cobas(®) PSC, DBS and fresh plasma specimens were collected from each patient. All specimens were tested for VL using CAP/CTM v2.0. Sensitivity and specificity of viral load using DBS, capillary and venous PSC specimens were estimated. Viral load obtained in fresh plasma specimen was used as reference and a threshold of 1000 copies/ml was considered for the analyses. RESULTS: From the total 613 patients included for the study, 2444 specimens including DBS (613), plasma (613), venous cobas(®) PSC (609) and capillary cobas(®) PSC (609) were collected and 2407 results were obtained. Sensitivity and specificity of the VL using venous cobas(®)PSC specimen at 1000 copies/ml threshold were 99.8% and 98.1% respectively, whereas for capillary cobas(®) PSC sensitivity was 99.6% and specificity was 97.2%. For DBS VL, sensitivity was 96.9% and specificity was 81.8%. Misclassification rate was more prominent in DBS specimens (5.9%), but lower in venous and capillary cobas(®)PSC with a rate of 0.3% and 0.7% respectively. CONCLUSION: The cobas(®) PSC specimen has improved performance over DBS for more accurate VL testing aligned with plasma testing. The use of this specimen type can increase the rates of reliable VL results and this will improve the quality of VL monitoring of HIV-positive patients in low-income settings. Public Library of Science 2020-05-06 /pmc/articles/PMC7202605/ /pubmed/32374748 http://dx.doi.org/10.1371/journal.pone.0232122 Text en © 2020 Vubil et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Vubil, Adolfo Zicai, Ana Flora Sitoe, Nádia Nhachigule, Carina Meggi, Bindiya Loquiha, Osvaldo Viegas, Sofia Mabunda, Nédio Scott, Lesley Jani, Ilesh Accurate HIV viral load measurement in primary health care settings using the cobas(®) plasma separation card |
title | Accurate HIV viral load measurement in primary health care settings using the cobas(®) plasma separation card |
title_full | Accurate HIV viral load measurement in primary health care settings using the cobas(®) plasma separation card |
title_fullStr | Accurate HIV viral load measurement in primary health care settings using the cobas(®) plasma separation card |
title_full_unstemmed | Accurate HIV viral load measurement in primary health care settings using the cobas(®) plasma separation card |
title_short | Accurate HIV viral load measurement in primary health care settings using the cobas(®) plasma separation card |
title_sort | accurate hiv viral load measurement in primary health care settings using the cobas(®) plasma separation card |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7202605/ https://www.ncbi.nlm.nih.gov/pubmed/32374748 http://dx.doi.org/10.1371/journal.pone.0232122 |
work_keys_str_mv | AT vubiladolfo accuratehivviralloadmeasurementinprimaryhealthcaresettingsusingthecobasplasmaseparationcard AT zicaianaflora accuratehivviralloadmeasurementinprimaryhealthcaresettingsusingthecobasplasmaseparationcard AT sitoenadia accuratehivviralloadmeasurementinprimaryhealthcaresettingsusingthecobasplasmaseparationcard AT nhachigulecarina accuratehivviralloadmeasurementinprimaryhealthcaresettingsusingthecobasplasmaseparationcard AT meggibindiya accuratehivviralloadmeasurementinprimaryhealthcaresettingsusingthecobasplasmaseparationcard AT loquihaosvaldo accuratehivviralloadmeasurementinprimaryhealthcaresettingsusingthecobasplasmaseparationcard AT viegassofia accuratehivviralloadmeasurementinprimaryhealthcaresettingsusingthecobasplasmaseparationcard AT mabundanedio accuratehivviralloadmeasurementinprimaryhealthcaresettingsusingthecobasplasmaseparationcard AT scottlesley accuratehivviralloadmeasurementinprimaryhealthcaresettingsusingthecobasplasmaseparationcard AT janiilesh accuratehivviralloadmeasurementinprimaryhealthcaresettingsusingthecobasplasmaseparationcard |