Cargando…

Inverse Laplace transform and multiexponential fitting analysis of T2 relaxometry data: a phantom study with aqueous and fat containing samples

BACKGROUND: The inverse Laplace transform (ILT) is the most widely used method for T2 relaxometry data analysis. This study examines the qualitative agreement of ILT and a proposed multiexponential (Mexp method) regarding the number of T2 components. We performed a feasibility study for the voxelwis...

Descripción completa

Detalles Bibliográficos
Autores principales: Ioannidis, Georgios S., Nikiforaki, Katerina, Kalaitzakis, Georgios, Karantanas, Apostolos, Marias, Kostas, Maris, Thomas G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7203287/
https://www.ncbi.nlm.nih.gov/pubmed/32378090
http://dx.doi.org/10.1186/s41747-020-00154-5
_version_ 1783529849599557632
author Ioannidis, Georgios S.
Nikiforaki, Katerina
Kalaitzakis, Georgios
Karantanas, Apostolos
Marias, Kostas
Maris, Thomas G.
author_facet Ioannidis, Georgios S.
Nikiforaki, Katerina
Kalaitzakis, Georgios
Karantanas, Apostolos
Marias, Kostas
Maris, Thomas G.
author_sort Ioannidis, Georgios S.
collection PubMed
description BACKGROUND: The inverse Laplace transform (ILT) is the most widely used method for T2 relaxometry data analysis. This study examines the qualitative agreement of ILT and a proposed multiexponential (Mexp method) regarding the number of T2 components. We performed a feasibility study for the voxelwise characterisation of heterogeneous tissue with T2 relaxometry. METHODS: Eleven samples of aqueous, fatty and mixed composition were analysed using ILT and Mexp. The phantom was imaged using a 1.5-T system with a single slice T2 relaxometry 25-echo Carr-Purcell-Meiboom-Gill sequence in order to obtain the T2 decay curve with 25 equidistant echo times. The adjusted R(2) goodness of fit criterion was used to determine the number of T2 components using the Mexp method on a voxel-based analysis. Comparison of mean and standard deviation of T2 values for both methods was performed by fitting a Gaussian function to the ILT resulting vector. RESULTS: Phantom results showed pure monoexponential decay for acetone and water and pure biexponential behaviour for corn oil, egg yolk, and 35% fat milk cream, while mixtures of egg whites and yolks as well as milk creams with 12–20% fatty composition exhibit mixed monoexponential and biexponential behaviour at different fractions. The number of T2 components by the Mexp method was compared to the ILT-derived spectrum as ground truth. CONCLUSIONS: Mexp analysis with the adjusted R(2) criterion can be used for the detection of the T2 distribution of aqueous, fatty and mixed samples with the added advantage of voxelwise mapping.
format Online
Article
Text
id pubmed-7203287
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-72032872020-05-12 Inverse Laplace transform and multiexponential fitting analysis of T2 relaxometry data: a phantom study with aqueous and fat containing samples Ioannidis, Georgios S. Nikiforaki, Katerina Kalaitzakis, Georgios Karantanas, Apostolos Marias, Kostas Maris, Thomas G. Eur Radiol Exp Original Article BACKGROUND: The inverse Laplace transform (ILT) is the most widely used method for T2 relaxometry data analysis. This study examines the qualitative agreement of ILT and a proposed multiexponential (Mexp method) regarding the number of T2 components. We performed a feasibility study for the voxelwise characterisation of heterogeneous tissue with T2 relaxometry. METHODS: Eleven samples of aqueous, fatty and mixed composition were analysed using ILT and Mexp. The phantom was imaged using a 1.5-T system with a single slice T2 relaxometry 25-echo Carr-Purcell-Meiboom-Gill sequence in order to obtain the T2 decay curve with 25 equidistant echo times. The adjusted R(2) goodness of fit criterion was used to determine the number of T2 components using the Mexp method on a voxel-based analysis. Comparison of mean and standard deviation of T2 values for both methods was performed by fitting a Gaussian function to the ILT resulting vector. RESULTS: Phantom results showed pure monoexponential decay for acetone and water and pure biexponential behaviour for corn oil, egg yolk, and 35% fat milk cream, while mixtures of egg whites and yolks as well as milk creams with 12–20% fatty composition exhibit mixed monoexponential and biexponential behaviour at different fractions. The number of T2 components by the Mexp method was compared to the ILT-derived spectrum as ground truth. CONCLUSIONS: Mexp analysis with the adjusted R(2) criterion can be used for the detection of the T2 distribution of aqueous, fatty and mixed samples with the added advantage of voxelwise mapping. Springer International Publishing 2020-05-07 /pmc/articles/PMC7203287/ /pubmed/32378090 http://dx.doi.org/10.1186/s41747-020-00154-5 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Article
Ioannidis, Georgios S.
Nikiforaki, Katerina
Kalaitzakis, Georgios
Karantanas, Apostolos
Marias, Kostas
Maris, Thomas G.
Inverse Laplace transform and multiexponential fitting analysis of T2 relaxometry data: a phantom study with aqueous and fat containing samples
title Inverse Laplace transform and multiexponential fitting analysis of T2 relaxometry data: a phantom study with aqueous and fat containing samples
title_full Inverse Laplace transform and multiexponential fitting analysis of T2 relaxometry data: a phantom study with aqueous and fat containing samples
title_fullStr Inverse Laplace transform and multiexponential fitting analysis of T2 relaxometry data: a phantom study with aqueous and fat containing samples
title_full_unstemmed Inverse Laplace transform and multiexponential fitting analysis of T2 relaxometry data: a phantom study with aqueous and fat containing samples
title_short Inverse Laplace transform and multiexponential fitting analysis of T2 relaxometry data: a phantom study with aqueous and fat containing samples
title_sort inverse laplace transform and multiexponential fitting analysis of t2 relaxometry data: a phantom study with aqueous and fat containing samples
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7203287/
https://www.ncbi.nlm.nih.gov/pubmed/32378090
http://dx.doi.org/10.1186/s41747-020-00154-5
work_keys_str_mv AT ioannidisgeorgioss inverselaplacetransformandmultiexponentialfittinganalysisoft2relaxometrydataaphantomstudywithaqueousandfatcontainingsamples
AT nikiforakikaterina inverselaplacetransformandmultiexponentialfittinganalysisoft2relaxometrydataaphantomstudywithaqueousandfatcontainingsamples
AT kalaitzakisgeorgios inverselaplacetransformandmultiexponentialfittinganalysisoft2relaxometrydataaphantomstudywithaqueousandfatcontainingsamples
AT karantanasapostolos inverselaplacetransformandmultiexponentialfittinganalysisoft2relaxometrydataaphantomstudywithaqueousandfatcontainingsamples
AT mariaskostas inverselaplacetransformandmultiexponentialfittinganalysisoft2relaxometrydataaphantomstudywithaqueousandfatcontainingsamples
AT maristhomasg inverselaplacetransformandmultiexponentialfittinganalysisoft2relaxometrydataaphantomstudywithaqueousandfatcontainingsamples