Cargando…

APPLICATION OF TIME-AVERAGED AND INTEGRAL-BASED MEASURE FOR MEASUREMENT RESULTS VARIABILITY REDUCTION IN GSM/DCS/UMTS SYSTEMS

Since EMF levels from wireless telecommunication networks are non-stationary and exhibit large temporal variations, the use of continuous measurements during extended periods (preferably 24 h or longer) with a data-logging system is required. Because of the short-term variations of E field, the 6-mi...

Descripción completa

Detalles Bibliográficos
Autores principales: Šuka, Darko, Pejović, Predrag, Simić-Pejović, Mirjana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7203997/
https://www.ncbi.nlm.nih.gov/pubmed/31297514
http://dx.doi.org/10.1093/rpd/ncz154
_version_ 1783529973545435136
author Šuka, Darko
Pejović, Predrag
Simić-Pejović, Mirjana
author_facet Šuka, Darko
Pejović, Predrag
Simić-Pejović, Mirjana
author_sort Šuka, Darko
collection PubMed
description Since EMF levels from wireless telecommunication networks are non-stationary and exhibit large temporal variations, the use of continuous measurements during extended periods (preferably 24 h or longer) with a data-logging system is required. Because of the short-term variations of E field, the 6-min measurements and 6-min averaged results to obtain the mean level strength at a given place appear to be dependent on the time of measurements during the day. This paper presents a new (integral-based) measure to evaluate electromagnetic exposure. The new measure is a pure physical descriptor of the amount of exposed energy density (a parameter accumulated from instantaneous power density values in time). To confirm previous observations, continuous measurements with personal exposure metre were recorded 24 h a day for two weeks at every location in urban area, 14 different locations in total. Additionally, to check temporal variations and repeatability of exposure assessment, a week of prolonged measurements was taken 6 months later, making in total three weeks of measurements at 2 locations. Day-to-day repeatability of RF-EMF exposure was analysed through the time-averaged and integral-based measure. The analysis is based on approximately 5.1 million data samples (1.7 million for each band). The ratio between the maximum and minimum instantaneous (maximum and minimum 6-min averaged) E field values during the day could reach up to 25 dB (20 dB). Therefore, great variability in the results may occur. By applying the 24 h time-averaged and integral-based measure on a 24 h data set of measurements, the variability of daily exposure could stay within ±20% of the week mean level obtained either with the time-averaged or integral-based measure. Both, the time-averaged E field and integral-based power density exposures of the general public in all locations were found to be well below the general public exposure limits of the ICNIRP guidelines.
format Online
Article
Text
id pubmed-7203997
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-72039972020-05-11 APPLICATION OF TIME-AVERAGED AND INTEGRAL-BASED MEASURE FOR MEASUREMENT RESULTS VARIABILITY REDUCTION IN GSM/DCS/UMTS SYSTEMS Šuka, Darko Pejović, Predrag Simić-Pejović, Mirjana Radiat Prot Dosimetry Paper Since EMF levels from wireless telecommunication networks are non-stationary and exhibit large temporal variations, the use of continuous measurements during extended periods (preferably 24 h or longer) with a data-logging system is required. Because of the short-term variations of E field, the 6-min measurements and 6-min averaged results to obtain the mean level strength at a given place appear to be dependent on the time of measurements during the day. This paper presents a new (integral-based) measure to evaluate electromagnetic exposure. The new measure is a pure physical descriptor of the amount of exposed energy density (a parameter accumulated from instantaneous power density values in time). To confirm previous observations, continuous measurements with personal exposure metre were recorded 24 h a day for two weeks at every location in urban area, 14 different locations in total. Additionally, to check temporal variations and repeatability of exposure assessment, a week of prolonged measurements was taken 6 months later, making in total three weeks of measurements at 2 locations. Day-to-day repeatability of RF-EMF exposure was analysed through the time-averaged and integral-based measure. The analysis is based on approximately 5.1 million data samples (1.7 million for each band). The ratio between the maximum and minimum instantaneous (maximum and minimum 6-min averaged) E field values during the day could reach up to 25 dB (20 dB). Therefore, great variability in the results may occur. By applying the 24 h time-averaged and integral-based measure on a 24 h data set of measurements, the variability of daily exposure could stay within ±20% of the week mean level obtained either with the time-averaged or integral-based measure. Both, the time-averaged E field and integral-based power density exposures of the general public in all locations were found to be well below the general public exposure limits of the ICNIRP guidelines. Oxford University Press 2019-12 2019-07-12 /pmc/articles/PMC7203997/ /pubmed/31297514 http://dx.doi.org/10.1093/rpd/ncz154 Text en © The Author(s) 2019. Published by Oxford University Press. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Paper
Šuka, Darko
Pejović, Predrag
Simić-Pejović, Mirjana
APPLICATION OF TIME-AVERAGED AND INTEGRAL-BASED MEASURE FOR MEASUREMENT RESULTS VARIABILITY REDUCTION IN GSM/DCS/UMTS SYSTEMS
title APPLICATION OF TIME-AVERAGED AND INTEGRAL-BASED MEASURE FOR MEASUREMENT RESULTS VARIABILITY REDUCTION IN GSM/DCS/UMTS SYSTEMS
title_full APPLICATION OF TIME-AVERAGED AND INTEGRAL-BASED MEASURE FOR MEASUREMENT RESULTS VARIABILITY REDUCTION IN GSM/DCS/UMTS SYSTEMS
title_fullStr APPLICATION OF TIME-AVERAGED AND INTEGRAL-BASED MEASURE FOR MEASUREMENT RESULTS VARIABILITY REDUCTION IN GSM/DCS/UMTS SYSTEMS
title_full_unstemmed APPLICATION OF TIME-AVERAGED AND INTEGRAL-BASED MEASURE FOR MEASUREMENT RESULTS VARIABILITY REDUCTION IN GSM/DCS/UMTS SYSTEMS
title_short APPLICATION OF TIME-AVERAGED AND INTEGRAL-BASED MEASURE FOR MEASUREMENT RESULTS VARIABILITY REDUCTION IN GSM/DCS/UMTS SYSTEMS
title_sort application of time-averaged and integral-based measure for measurement results variability reduction in gsm/dcs/umts systems
topic Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7203997/
https://www.ncbi.nlm.nih.gov/pubmed/31297514
http://dx.doi.org/10.1093/rpd/ncz154
work_keys_str_mv AT sukadarko applicationoftimeaveragedandintegralbasedmeasureformeasurementresultsvariabilityreductioningsmdcsumtssystems
AT pejovicpredrag applicationoftimeaveragedandintegralbasedmeasureformeasurementresultsvariabilityreductioningsmdcsumtssystems
AT simicpejovicmirjana applicationoftimeaveragedandintegralbasedmeasureformeasurementresultsvariabilityreductioningsmdcsumtssystems