Cargando…

Serial Peripheral Blood Gene Expression Profiling to Assess Immune Quiescence in Kidney Transplant Recipients with Stable Renal Function

BACKGROUND: TruGraf is a blood-based biomarker test that measures differential expression of a collection of genes that have been shown to correlate with surveillance biopsy results. However, in the majority of U.S. transplant centers, surveillance biopsies are not performed. The objectives of this...

Descripción completa

Detalles Bibliográficos
Autores principales: Peddi, V. Ram, Patel, Parul S., Schieve, Courtney, Rose, Stan, First, M. Roy
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7204430/
https://www.ncbi.nlm.nih.gov/pubmed/32341330
http://dx.doi.org/10.12659/AOT.920839
_version_ 1783530063677882368
author Peddi, V. Ram
Patel, Parul S.
Schieve, Courtney
Rose, Stan
First, M. Roy
author_facet Peddi, V. Ram
Patel, Parul S.
Schieve, Courtney
Rose, Stan
First, M. Roy
author_sort Peddi, V. Ram
collection PubMed
description BACKGROUND: TruGraf is a blood-based biomarker test that measures differential expression of a collection of genes that have been shown to correlate with surveillance biopsy results. However, in the majority of U.S. transplant centers, surveillance biopsies are not performed. The objectives of this study were to evaluate the clinical validity of TruGraf in stable kidney transplant recipients and to demonstrate the potential clinical utility of serial TruGraf testing in a center not utilizing surveillance biopsies. MATERIAL/METHODS: Serum creatinine levels, TruGraf testing at multiple time points, and subsequent clinical follow-up were obtained for 28 patients. RESULTS: Overall concordance of TruGraf results, when compared with independent clinical assessment of testing, was 77% (54/70) for all tests; 79% (22/28) for test 1, 75% (21/28) for test 2, and 79% (11/14) for test 3. The negative predictive value (NPV) was 98.0%. Analysis of clinical utility indicated that 77% of TruGraf results would have been useful in patient management. CONCLUSIONS: Our results indicate the value of serial TruGraf testing in those transplant centers that do not perform surveillance biopsies as part of their standard of care. The high negative predictive value indicates the ability of TruGraf to confirm immune quiescence with a high degree of probability in patients with a Transplant eXcellence (TX) result, without the need to perform a surveillance biopsy.
format Online
Article
Text
id pubmed-7204430
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-72044302020-05-11 Serial Peripheral Blood Gene Expression Profiling to Assess Immune Quiescence in Kidney Transplant Recipients with Stable Renal Function Peddi, V. Ram Patel, Parul S. Schieve, Courtney Rose, Stan First, M. Roy Ann Transplant Original Paper BACKGROUND: TruGraf is a blood-based biomarker test that measures differential expression of a collection of genes that have been shown to correlate with surveillance biopsy results. However, in the majority of U.S. transplant centers, surveillance biopsies are not performed. The objectives of this study were to evaluate the clinical validity of TruGraf in stable kidney transplant recipients and to demonstrate the potential clinical utility of serial TruGraf testing in a center not utilizing surveillance biopsies. MATERIAL/METHODS: Serum creatinine levels, TruGraf testing at multiple time points, and subsequent clinical follow-up were obtained for 28 patients. RESULTS: Overall concordance of TruGraf results, when compared with independent clinical assessment of testing, was 77% (54/70) for all tests; 79% (22/28) for test 1, 75% (21/28) for test 2, and 79% (11/14) for test 3. The negative predictive value (NPV) was 98.0%. Analysis of clinical utility indicated that 77% of TruGraf results would have been useful in patient management. CONCLUSIONS: Our results indicate the value of serial TruGraf testing in those transplant centers that do not perform surveillance biopsies as part of their standard of care. The high negative predictive value indicates the ability of TruGraf to confirm immune quiescence with a high degree of probability in patients with a Transplant eXcellence (TX) result, without the need to perform a surveillance biopsy. International Scientific Literature, Inc. 2020-04-28 /pmc/articles/PMC7204430/ /pubmed/32341330 http://dx.doi.org/10.12659/AOT.920839 Text en © Ann Transplant, 2020 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Original Paper
Peddi, V. Ram
Patel, Parul S.
Schieve, Courtney
Rose, Stan
First, M. Roy
Serial Peripheral Blood Gene Expression Profiling to Assess Immune Quiescence in Kidney Transplant Recipients with Stable Renal Function
title Serial Peripheral Blood Gene Expression Profiling to Assess Immune Quiescence in Kidney Transplant Recipients with Stable Renal Function
title_full Serial Peripheral Blood Gene Expression Profiling to Assess Immune Quiescence in Kidney Transplant Recipients with Stable Renal Function
title_fullStr Serial Peripheral Blood Gene Expression Profiling to Assess Immune Quiescence in Kidney Transplant Recipients with Stable Renal Function
title_full_unstemmed Serial Peripheral Blood Gene Expression Profiling to Assess Immune Quiescence in Kidney Transplant Recipients with Stable Renal Function
title_short Serial Peripheral Blood Gene Expression Profiling to Assess Immune Quiescence in Kidney Transplant Recipients with Stable Renal Function
title_sort serial peripheral blood gene expression profiling to assess immune quiescence in kidney transplant recipients with stable renal function
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7204430/
https://www.ncbi.nlm.nih.gov/pubmed/32341330
http://dx.doi.org/10.12659/AOT.920839
work_keys_str_mv AT peddivram serialperipheralbloodgeneexpressionprofilingtoassessimmunequiescenceinkidneytransplantrecipientswithstablerenalfunction
AT patelparuls serialperipheralbloodgeneexpressionprofilingtoassessimmunequiescenceinkidneytransplantrecipientswithstablerenalfunction
AT schievecourtney serialperipheralbloodgeneexpressionprofilingtoassessimmunequiescenceinkidneytransplantrecipientswithstablerenalfunction
AT rosestan serialperipheralbloodgeneexpressionprofilingtoassessimmunequiescenceinkidneytransplantrecipientswithstablerenalfunction
AT firstmroy serialperipheralbloodgeneexpressionprofilingtoassessimmunequiescenceinkidneytransplantrecipientswithstablerenalfunction