Cargando…
Prototype single-balloon enteroscopy with passive bending and high force transmission improves depth of insertion in the small intestine
BACKGROUND/AIMS: We retrospectively analyzed Crohn’s disease (CD) patients with small intestinal strictures who underwent single-balloon enteroscopy (SBE) to ascertain whether prototype SBEs with a passive bending mechanism and high force transmission insertion tube had better insertability in the s...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Association for the Study of Intestinal Diseases
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7206344/ https://www.ncbi.nlm.nih.gov/pubmed/32252502 http://dx.doi.org/10.5217/ir.2019.09150 |
_version_ | 1783530397146021888 |
---|---|
author | Morita, Yasuhiro Bamba, Shigeki Inatomi, Osamu Takahashi, Kenichiro Imai, Takayuki Murata, Masaki Ohno, Masashi Sasaki, Masaya Tsujikawa, Tomoyuki Andoh, Akira |
author_facet | Morita, Yasuhiro Bamba, Shigeki Inatomi, Osamu Takahashi, Kenichiro Imai, Takayuki Murata, Masaki Ohno, Masashi Sasaki, Masaya Tsujikawa, Tomoyuki Andoh, Akira |
author_sort | Morita, Yasuhiro |
collection | PubMed |
description | BACKGROUND/AIMS: We retrospectively analyzed Crohn’s disease (CD) patients with small intestinal strictures who underwent single-balloon enteroscopy (SBE) to ascertain whether prototype SBEs with a passive bending mechanism and high force transmission insertion tube had better insertability in the small intestine than a conventional SBE. METHODS: Among 253 CD patients who underwent SBE, we identified 94 CD patients who had undergone attempted endoscopic balloon dilatation (EBD) for small intestinal stenosis for inclusion in this study. We analyzed whether the type of scope used for their initial procedure affected the cumulative surgery-free rate. For the insertability analysis, patients who underwent SBE at least twice were divided into 3 groups according to the type of scope used: conventional SBE only, prototype SBE only, and both conventional and prototype SBEs. For each group, depth of insertion, procedure time, and number of EBDs were compared in the same patient at different time points. RESULTS: The success rate of EBD was 88.3%. The 5- and 10-year cumulative surgery-free rate was 75.7% and 72.8%, respectively. Cox regression analysis indicated that the factors contributing to surgery were long stricture (≥2 cm), EBD failure, and elevated Crohn’s Disease Activity Index, but not the type of scope used for EBD. The prototype SBEs significantly improved the depth of insertion (P=0.03, Wilcoxon’s signed-rank test). CONCLUSIONS: In CD patients with small intestinal stenosis, the prototype SBEs with a passive bending mechanism and high force transmission insertion tube did not improve long-term EBD outcome but did improve deep insertability. (Clinical Trial Registration No. UMIN000037102) |
format | Online Article Text |
id | pubmed-7206344 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Korean Association for the Study of Intestinal Diseases |
record_format | MEDLINE/PubMed |
spelling | pubmed-72063442020-05-14 Prototype single-balloon enteroscopy with passive bending and high force transmission improves depth of insertion in the small intestine Morita, Yasuhiro Bamba, Shigeki Inatomi, Osamu Takahashi, Kenichiro Imai, Takayuki Murata, Masaki Ohno, Masashi Sasaki, Masaya Tsujikawa, Tomoyuki Andoh, Akira Intest Res Original Article BACKGROUND/AIMS: We retrospectively analyzed Crohn’s disease (CD) patients with small intestinal strictures who underwent single-balloon enteroscopy (SBE) to ascertain whether prototype SBEs with a passive bending mechanism and high force transmission insertion tube had better insertability in the small intestine than a conventional SBE. METHODS: Among 253 CD patients who underwent SBE, we identified 94 CD patients who had undergone attempted endoscopic balloon dilatation (EBD) for small intestinal stenosis for inclusion in this study. We analyzed whether the type of scope used for their initial procedure affected the cumulative surgery-free rate. For the insertability analysis, patients who underwent SBE at least twice were divided into 3 groups according to the type of scope used: conventional SBE only, prototype SBE only, and both conventional and prototype SBEs. For each group, depth of insertion, procedure time, and number of EBDs were compared in the same patient at different time points. RESULTS: The success rate of EBD was 88.3%. The 5- and 10-year cumulative surgery-free rate was 75.7% and 72.8%, respectively. Cox regression analysis indicated that the factors contributing to surgery were long stricture (≥2 cm), EBD failure, and elevated Crohn’s Disease Activity Index, but not the type of scope used for EBD. The prototype SBEs significantly improved the depth of insertion (P=0.03, Wilcoxon’s signed-rank test). CONCLUSIONS: In CD patients with small intestinal stenosis, the prototype SBEs with a passive bending mechanism and high force transmission insertion tube did not improve long-term EBD outcome but did improve deep insertability. (Clinical Trial Registration No. UMIN000037102) Korean Association for the Study of Intestinal Diseases 2020-04 2020-04-09 /pmc/articles/PMC7206344/ /pubmed/32252502 http://dx.doi.org/10.5217/ir.2019.09150 Text en © Copyright 2020. Korean Association for the Study of Intestinal Diseases. All rights reserved. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Morita, Yasuhiro Bamba, Shigeki Inatomi, Osamu Takahashi, Kenichiro Imai, Takayuki Murata, Masaki Ohno, Masashi Sasaki, Masaya Tsujikawa, Tomoyuki Andoh, Akira Prototype single-balloon enteroscopy with passive bending and high force transmission improves depth of insertion in the small intestine |
title | Prototype single-balloon enteroscopy with passive bending and high force transmission improves depth of insertion in the small intestine |
title_full | Prototype single-balloon enteroscopy with passive bending and high force transmission improves depth of insertion in the small intestine |
title_fullStr | Prototype single-balloon enteroscopy with passive bending and high force transmission improves depth of insertion in the small intestine |
title_full_unstemmed | Prototype single-balloon enteroscopy with passive bending and high force transmission improves depth of insertion in the small intestine |
title_short | Prototype single-balloon enteroscopy with passive bending and high force transmission improves depth of insertion in the small intestine |
title_sort | prototype single-balloon enteroscopy with passive bending and high force transmission improves depth of insertion in the small intestine |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7206344/ https://www.ncbi.nlm.nih.gov/pubmed/32252502 http://dx.doi.org/10.5217/ir.2019.09150 |
work_keys_str_mv | AT moritayasuhiro prototypesingleballoonenteroscopywithpassivebendingandhighforcetransmissionimprovesdepthofinsertioninthesmallintestine AT bambashigeki prototypesingleballoonenteroscopywithpassivebendingandhighforcetransmissionimprovesdepthofinsertioninthesmallintestine AT inatomiosamu prototypesingleballoonenteroscopywithpassivebendingandhighforcetransmissionimprovesdepthofinsertioninthesmallintestine AT takahashikenichiro prototypesingleballoonenteroscopywithpassivebendingandhighforcetransmissionimprovesdepthofinsertioninthesmallintestine AT imaitakayuki prototypesingleballoonenteroscopywithpassivebendingandhighforcetransmissionimprovesdepthofinsertioninthesmallintestine AT muratamasaki prototypesingleballoonenteroscopywithpassivebendingandhighforcetransmissionimprovesdepthofinsertioninthesmallintestine AT ohnomasashi prototypesingleballoonenteroscopywithpassivebendingandhighforcetransmissionimprovesdepthofinsertioninthesmallintestine AT sasakimasaya prototypesingleballoonenteroscopywithpassivebendingandhighforcetransmissionimprovesdepthofinsertioninthesmallintestine AT tsujikawatomoyuki prototypesingleballoonenteroscopywithpassivebendingandhighforcetransmissionimprovesdepthofinsertioninthesmallintestine AT andohakira prototypesingleballoonenteroscopywithpassivebendingandhighforcetransmissionimprovesdepthofinsertioninthesmallintestine |