Validation study of small-angle X-ray scattering tensor tomography

Small-angle scattering tensor tomography (SASTT) is a recently developed technique able to tomographically reconstruct the 3D reciprocal space from voxels within a bulk volume. SASTT extends the concept of X-ray computed tomography, which typically reconstructs scalar values, by reconstructing a ten...

Descripción completa

Detalles Bibliográficos
Autores principales: Guizar-Sicairos, Manuel, Georgiadis, Marios, Liebi, Marianne
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7206543/
https://www.ncbi.nlm.nih.gov/pubmed/32381781
http://dx.doi.org/10.1107/S1600577520003860
_version_ 1783530435990519808
author Guizar-Sicairos, Manuel
Georgiadis, Marios
Liebi, Marianne
author_facet Guizar-Sicairos, Manuel
Georgiadis, Marios
Liebi, Marianne
author_sort Guizar-Sicairos, Manuel
collection PubMed
description Small-angle scattering tensor tomography (SASTT) is a recently developed technique able to tomographically reconstruct the 3D reciprocal space from voxels within a bulk volume. SASTT extends the concept of X-ray computed tomography, which typically reconstructs scalar values, by reconstructing a tensor per voxel, which represents the local nanostructure 3D organization. In this study, the nanostructure orientation in a human trabecular-bone sample obtained by SASTT was validated by sectioning the sample and using 3D scanning small-angle X-ray scattering (3D sSAXS) to measure and analyze the orientation from single voxels within each thin section. Besides the presence of cutting artefacts from the slicing process, the nanostructure orientations obtained with the two independent methods were in good agreement, as quantified with the absolute value of the dot product calculated between the nanostructure main orientations obtained in each voxel. The average dot product per voxel over the full sample containing over 10 000 voxels was 0.84, and in six slices, in which fewer cutting artefacts were observed, the dot product increased to 0.91. In addition, SAXS tensor tomography not only yields orientation information but can also reconstruct the full 3D reciprocal-space map. It is shown that the measured anisotropic scattering for individual voxels was reproduced from the SASTT reconstruction in each voxel of the 3D sample. The scattering curves along different 3D directions are validated with data from single voxels, demonstrating SASTT’s potential for a separate analysis of nanostructure orientation and structural information from the angle-dependent intensity distribution.
format Online
Article
Text
id pubmed-7206543
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-72065432020-05-19 Validation study of small-angle X-ray scattering tensor tomography Guizar-Sicairos, Manuel Georgiadis, Marios Liebi, Marianne J Synchrotron Radiat Research Papers Small-angle scattering tensor tomography (SASTT) is a recently developed technique able to tomographically reconstruct the 3D reciprocal space from voxels within a bulk volume. SASTT extends the concept of X-ray computed tomography, which typically reconstructs scalar values, by reconstructing a tensor per voxel, which represents the local nanostructure 3D organization. In this study, the nanostructure orientation in a human trabecular-bone sample obtained by SASTT was validated by sectioning the sample and using 3D scanning small-angle X-ray scattering (3D sSAXS) to measure and analyze the orientation from single voxels within each thin section. Besides the presence of cutting artefacts from the slicing process, the nanostructure orientations obtained with the two independent methods were in good agreement, as quantified with the absolute value of the dot product calculated between the nanostructure main orientations obtained in each voxel. The average dot product per voxel over the full sample containing over 10 000 voxels was 0.84, and in six slices, in which fewer cutting artefacts were observed, the dot product increased to 0.91. In addition, SAXS tensor tomography not only yields orientation information but can also reconstruct the full 3D reciprocal-space map. It is shown that the measured anisotropic scattering for individual voxels was reproduced from the SASTT reconstruction in each voxel of the 3D sample. The scattering curves along different 3D directions are validated with data from single voxels, demonstrating SASTT’s potential for a separate analysis of nanostructure orientation and structural information from the angle-dependent intensity distribution. International Union of Crystallography 2020-04-22 /pmc/articles/PMC7206543/ /pubmed/32381781 http://dx.doi.org/10.1107/S1600577520003860 Text en © Guizar-Sicairos et al. 2020 http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.http://creativecommons.org/licenses/by/4.0/
spellingShingle Research Papers
Guizar-Sicairos, Manuel
Georgiadis, Marios
Liebi, Marianne
Validation study of small-angle X-ray scattering tensor tomography
title Validation study of small-angle X-ray scattering tensor tomography
title_full Validation study of small-angle X-ray scattering tensor tomography
title_fullStr Validation study of small-angle X-ray scattering tensor tomography
title_full_unstemmed Validation study of small-angle X-ray scattering tensor tomography
title_short Validation study of small-angle X-ray scattering tensor tomography
title_sort validation study of small-angle x-ray scattering tensor tomography
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7206543/
https://www.ncbi.nlm.nih.gov/pubmed/32381781
http://dx.doi.org/10.1107/S1600577520003860
work_keys_str_mv AT guizarsicairosmanuel validationstudyofsmallanglexrayscatteringtensortomography
AT georgiadismarios validationstudyofsmallanglexrayscatteringtensortomography
AT liebimarianne validationstudyofsmallanglexrayscatteringtensortomography