Cargando…

Application of droplet digital PCR for the detection of vector copy number in clinical CAR/TCR T cell products

BACKGROUND: Genetically engineered T cells have become an important therapy for B-cell malignancies. Measuring the efficiency of vector integration into the T cell genome is important for assessing the potency and safety of these cancer immunotherapies. METHODS: A digital droplet polymerase chain re...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Alex, Liu, Hui, Shi, Rongye, Cai, Yihua, Ma, Jinxia, Shao, Lipei, Rong, Victor, Gkitsas, Nikolaos, Lei, Hong, Highfill, Steven L., Panch, Sandhya, Stroncek, David F., Jin, Ping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7206671/
https://www.ncbi.nlm.nih.gov/pubmed/32384903
http://dx.doi.org/10.1186/s12967-020-02358-0
_version_ 1783530456012029952
author Lu, Alex
Liu, Hui
Shi, Rongye
Cai, Yihua
Ma, Jinxia
Shao, Lipei
Rong, Victor
Gkitsas, Nikolaos
Lei, Hong
Highfill, Steven L.
Panch, Sandhya
Stroncek, David F.
Jin, Ping
author_facet Lu, Alex
Liu, Hui
Shi, Rongye
Cai, Yihua
Ma, Jinxia
Shao, Lipei
Rong, Victor
Gkitsas, Nikolaos
Lei, Hong
Highfill, Steven L.
Panch, Sandhya
Stroncek, David F.
Jin, Ping
author_sort Lu, Alex
collection PubMed
description BACKGROUND: Genetically engineered T cells have become an important therapy for B-cell malignancies. Measuring the efficiency of vector integration into the T cell genome is important for assessing the potency and safety of these cancer immunotherapies. METHODS: A digital droplet polymerase chain reaction (ddPCR) assay was developed and evaluated for assessing the average number of lenti- and retroviral vectors integrated into Chimeric Antigen Receptor (CAR) and T Cell Receptor (TCR)-engineered T cells. RESULTS: The ddPCR assay consistently measured the concentration of an empty vector in solution and the average number of CAR and TCR vectors integrated into T cell populations. There was a linear relationship between the average vector copy number per cell measured by ddPCR and the proportion of cells transduced as measured by flow cytometry. Similar vector copy number measurements were obtained by different staff using the ddPCR assay, highlighting the assays reproducibility among technicians. Analysis of fresh and cryopreserved CAR T and TCR engineered T cells yielded similar results. CONCLUSIONS: ddPCR is a robust tool for accurate quantitation of average vector copy number in CAR and TCR engineered T cells. The assay is also applicable to other types of genetically engineered cells including Natural Killer cells and hematopoietic stem cells.
format Online
Article
Text
id pubmed-7206671
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-72066712020-05-14 Application of droplet digital PCR for the detection of vector copy number in clinical CAR/TCR T cell products Lu, Alex Liu, Hui Shi, Rongye Cai, Yihua Ma, Jinxia Shao, Lipei Rong, Victor Gkitsas, Nikolaos Lei, Hong Highfill, Steven L. Panch, Sandhya Stroncek, David F. Jin, Ping J Transl Med Research BACKGROUND: Genetically engineered T cells have become an important therapy for B-cell malignancies. Measuring the efficiency of vector integration into the T cell genome is important for assessing the potency and safety of these cancer immunotherapies. METHODS: A digital droplet polymerase chain reaction (ddPCR) assay was developed and evaluated for assessing the average number of lenti- and retroviral vectors integrated into Chimeric Antigen Receptor (CAR) and T Cell Receptor (TCR)-engineered T cells. RESULTS: The ddPCR assay consistently measured the concentration of an empty vector in solution and the average number of CAR and TCR vectors integrated into T cell populations. There was a linear relationship between the average vector copy number per cell measured by ddPCR and the proportion of cells transduced as measured by flow cytometry. Similar vector copy number measurements were obtained by different staff using the ddPCR assay, highlighting the assays reproducibility among technicians. Analysis of fresh and cryopreserved CAR T and TCR engineered T cells yielded similar results. CONCLUSIONS: ddPCR is a robust tool for accurate quantitation of average vector copy number in CAR and TCR engineered T cells. The assay is also applicable to other types of genetically engineered cells including Natural Killer cells and hematopoietic stem cells. BioMed Central 2020-05-08 /pmc/articles/PMC7206671/ /pubmed/32384903 http://dx.doi.org/10.1186/s12967-020-02358-0 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Lu, Alex
Liu, Hui
Shi, Rongye
Cai, Yihua
Ma, Jinxia
Shao, Lipei
Rong, Victor
Gkitsas, Nikolaos
Lei, Hong
Highfill, Steven L.
Panch, Sandhya
Stroncek, David F.
Jin, Ping
Application of droplet digital PCR for the detection of vector copy number in clinical CAR/TCR T cell products
title Application of droplet digital PCR for the detection of vector copy number in clinical CAR/TCR T cell products
title_full Application of droplet digital PCR for the detection of vector copy number in clinical CAR/TCR T cell products
title_fullStr Application of droplet digital PCR for the detection of vector copy number in clinical CAR/TCR T cell products
title_full_unstemmed Application of droplet digital PCR for the detection of vector copy number in clinical CAR/TCR T cell products
title_short Application of droplet digital PCR for the detection of vector copy number in clinical CAR/TCR T cell products
title_sort application of droplet digital pcr for the detection of vector copy number in clinical car/tcr t cell products
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7206671/
https://www.ncbi.nlm.nih.gov/pubmed/32384903
http://dx.doi.org/10.1186/s12967-020-02358-0
work_keys_str_mv AT lualex applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT liuhui applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT shirongye applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT caiyihua applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT majinxia applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT shaolipei applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT rongvictor applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT gkitsasnikolaos applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT leihong applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT highfillstevenl applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT panchsandhya applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT stroncekdavidf applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts
AT jinping applicationofdropletdigitalpcrforthedetectionofvectorcopynumberinclinicalcartcrtcellproducts