Cargando…

A radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer

PURPOSE: Schemes with high doses per fraction and small number of fractions are commonly used in high-dose-rate brachytherapy (HDR-BT) for prostate cancer. Our aim was to analyze the differences between published clinical results and the predictions of radiobiological models for absorbed dose requir...

Descripción completa

Detalles Bibliográficos
Autores principales: Guirado, Damián, Ruiz-Arrebola, Samuel, Tornero-López, Ana M., de la Vega, Jose M., Prada, Pedro J., Lallena, Antonio M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7207227/
https://www.ncbi.nlm.nih.gov/pubmed/32395145
http://dx.doi.org/10.5114/jcb.2020.94492
_version_ 1783530557982900224
author Guirado, Damián
Ruiz-Arrebola, Samuel
Tornero-López, Ana M.
de la Vega, Jose M.
Prada, Pedro J.
Lallena, Antonio M.
author_facet Guirado, Damián
Ruiz-Arrebola, Samuel
Tornero-López, Ana M.
de la Vega, Jose M.
Prada, Pedro J.
Lallena, Antonio M.
author_sort Guirado, Damián
collection PubMed
description PURPOSE: Schemes with high doses per fraction and small number of fractions are commonly used in high-dose-rate brachytherapy (HDR-BT) for prostate cancer. Our aim was to analyze the differences between published clinical results and the predictions of radiobiological models for absorbed dose required in a single fraction monotherapy HDR-BT. MATERIAL AND METHODS: Published HDR-BT clinical results for low- and intermediate-risk patients with prostate cancer were revised. For 13 clinical studies with 16 fractionation schedules between 1 and 9 fractions, a dose-response relation in terms of the biochemical control probability (BC) was established using Monte Carlo-based statistical methods. RESULTS: We obtained a value of α/β = 22.8 Gy (15.1-60.2 Gy) (95% CI) much larger than the values in the range 1.5-3.0 Gy that are usually considered to compare the results of different fractionation schemes in prostate cancer radiotherapy using doses per fraction below 6 Gy. The doses in a single fraction producing BC = 90% and 95% were 22.3 Gy (21.5-24.2 Gy) and 24.3 Gy (23.0-27.9 Gy), respectively. CONCLUSIONS: The α/β obtained in our analysis of 22.8 Gy for a range of dose per fraction between 6 and 20.5 Gy was much greater than the one currently estimated for prostate cancer using low doses per fraction. This high value of α/β explains reasonably well the data available in the region of high doses per fraction considered.
format Online
Article
Text
id pubmed-7207227
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-72072272020-05-11 A radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer Guirado, Damián Ruiz-Arrebola, Samuel Tornero-López, Ana M. de la Vega, Jose M. Prada, Pedro J. Lallena, Antonio M. J Contemp Brachytherapy Original Paper PURPOSE: Schemes with high doses per fraction and small number of fractions are commonly used in high-dose-rate brachytherapy (HDR-BT) for prostate cancer. Our aim was to analyze the differences between published clinical results and the predictions of radiobiological models for absorbed dose required in a single fraction monotherapy HDR-BT. MATERIAL AND METHODS: Published HDR-BT clinical results for low- and intermediate-risk patients with prostate cancer were revised. For 13 clinical studies with 16 fractionation schedules between 1 and 9 fractions, a dose-response relation in terms of the biochemical control probability (BC) was established using Monte Carlo-based statistical methods. RESULTS: We obtained a value of α/β = 22.8 Gy (15.1-60.2 Gy) (95% CI) much larger than the values in the range 1.5-3.0 Gy that are usually considered to compare the results of different fractionation schemes in prostate cancer radiotherapy using doses per fraction below 6 Gy. The doses in a single fraction producing BC = 90% and 95% were 22.3 Gy (21.5-24.2 Gy) and 24.3 Gy (23.0-27.9 Gy), respectively. CONCLUSIONS: The α/β obtained in our analysis of 22.8 Gy for a range of dose per fraction between 6 and 20.5 Gy was much greater than the one currently estimated for prostate cancer using low doses per fraction. This high value of α/β explains reasonably well the data available in the region of high doses per fraction considered. Termedia Publishing House 2020-04-18 2020-04 /pmc/articles/PMC7207227/ /pubmed/32395145 http://dx.doi.org/10.5114/jcb.2020.94492 Text en Copyright © 2020 Termedia http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0). License (http://creativecommons.org/licenses/by-nc-sa/4.0/)
spellingShingle Original Paper
Guirado, Damián
Ruiz-Arrebola, Samuel
Tornero-López, Ana M.
de la Vega, Jose M.
Prada, Pedro J.
Lallena, Antonio M.
A radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer
title A radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer
title_full A radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer
title_fullStr A radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer
title_full_unstemmed A radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer
title_short A radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer
title_sort radiobiological study of the schemes with a low number of fractions in high-dose-rate brachytherapy as monotherapy for prostate cancer
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7207227/
https://www.ncbi.nlm.nih.gov/pubmed/32395145
http://dx.doi.org/10.5114/jcb.2020.94492
work_keys_str_mv AT guiradodamian aradiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer
AT ruizarrebolasamuel aradiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer
AT tornerolopezanam aradiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer
AT delavegajosem aradiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer
AT pradapedroj aradiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer
AT lallenaantoniom aradiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer
AT guiradodamian radiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer
AT ruizarrebolasamuel radiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer
AT tornerolopezanam radiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer
AT delavegajosem radiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer
AT pradapedroj radiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer
AT lallenaantoniom radiobiologicalstudyoftheschemeswithalownumberoffractionsinhighdoseratebrachytherapyasmonotherapyforprostatecancer