Cargando…

MON-271 Identification of IGF-1 Variants in a Clinical Study of 307,000 Specimens: Discrepancies with General Population and Novel Discoveries

High resolution accurate mass (HRAM) mass spectrometry (MS) is a highly specific and robust method for identifying and quantifying intact IGF-1. However, protein variants with mass-to-charge ratios differing from wild type (WT) are not included in quantification. Previously, we developed a naming co...

Descripción completa

Detalles Bibliográficos
Autores principales: Motorykin, Ievgen, McPhaul, Michael John, Clarke, Nigel J, Wu, Zengru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7208636/
http://dx.doi.org/10.1210/jendso/bvaa046.1919
_version_ 1783530892345475072
author Motorykin, Ievgen
McPhaul, Michael John
Clarke, Nigel J
Wu, Zengru
author_facet Motorykin, Ievgen
McPhaul, Michael John
Clarke, Nigel J
Wu, Zengru
author_sort Motorykin, Ievgen
collection PubMed
description High resolution accurate mass (HRAM) mass spectrometry (MS) is a highly specific and robust method for identifying and quantifying intact IGF-1. However, protein variants with mass-to-charge ratios differing from wild type (WT) are not included in quantification. Previously, we developed a naming convention for isotopic peaks, called the Isotopic Peak Index (IP(i)) that helps identify variants by comparing their IP(i)s. This method cannot differentiate some variants; however, the relative retention time (rRT), which is defined as the difference between the chromatographic RT of a variant and that of the WT, may help in some cases. We report IGF-1 variants detected using rRT and IP(i); we also compare expected and observed frequency of common variants A67T and A70T. For IPi, 4 variant groups (VGs), each monitored at a single m/z ratio, were identified to make detection of 15 variants more efficient. Variants within each VG could be distinguished if they had different IP(i)s. To distinguish some variants in the same VG with the same IP(i), we used rRT. We also developed a tandem mass-spectrometry (MS/MS) method that uses specific fragment ions generated during fragmentation to distinguish between the most abundant variants, A67T and A70T. Of the 307,269 samples we analyzed, 1,266 (0.4%) variants were identified. IP(i) identified variants with different indices and the rRT approach distinguished between pairs of variants that IP(i) could not (A38V vs A67V; R55K vs R36Q). The following variants (and their count) were identified: R50W/T4M/A67T/A70T (1,210), A67V (23), A38V (9), P66A (6), R36Q/R50Q (5), V17M/V44M (5), A67S (4), R55K/R56K (3), T29I/T41I (1), S34N (1), S33P (1), Y31H (1). We observed a different relative frequency of A67T and A70T variants than expected based on a general population ExAC DNA database. We expected to detect 2.1-fold more A67T than A70T counts. However, DNA sequencing of 74 samples in this study identified 1.6-fold more A70T occurrences (46) than A67T (28). Overrepresentation of A70T may suggest its clinical significance. The A38V variant was predicted to occur 5.1-times in the population studied, but it was detected 9 times. The A67V variant was not present in the ExAC database, but it was detected in 23 patients. We detected 2 variants that did not match WT or expected variants; DNA sequencing identified them as new variants (S33P, Y31H). DNA sequencing also identified 3 new variants (R50Q, R56K, T41I) at different positions than expected. Using a few test samples, the tandem MS technique has shown its ability to distinguish between A67T and A70T. It will be applied to this patient set. IP(i) and rRT can be used together to identify and differentiate IGF-1 variants. Such an approach may provide improved estimates of variant frequencies and identify new variants.
format Online
Article
Text
id pubmed-7208636
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-72086362020-05-13 MON-271 Identification of IGF-1 Variants in a Clinical Study of 307,000 Specimens: Discrepancies with General Population and Novel Discoveries Motorykin, Ievgen McPhaul, Michael John Clarke, Nigel J Wu, Zengru J Endocr Soc Neuroendocrinology and Pituitary High resolution accurate mass (HRAM) mass spectrometry (MS) is a highly specific and robust method for identifying and quantifying intact IGF-1. However, protein variants with mass-to-charge ratios differing from wild type (WT) are not included in quantification. Previously, we developed a naming convention for isotopic peaks, called the Isotopic Peak Index (IP(i)) that helps identify variants by comparing their IP(i)s. This method cannot differentiate some variants; however, the relative retention time (rRT), which is defined as the difference between the chromatographic RT of a variant and that of the WT, may help in some cases. We report IGF-1 variants detected using rRT and IP(i); we also compare expected and observed frequency of common variants A67T and A70T. For IPi, 4 variant groups (VGs), each monitored at a single m/z ratio, were identified to make detection of 15 variants more efficient. Variants within each VG could be distinguished if they had different IP(i)s. To distinguish some variants in the same VG with the same IP(i), we used rRT. We also developed a tandem mass-spectrometry (MS/MS) method that uses specific fragment ions generated during fragmentation to distinguish between the most abundant variants, A67T and A70T. Of the 307,269 samples we analyzed, 1,266 (0.4%) variants were identified. IP(i) identified variants with different indices and the rRT approach distinguished between pairs of variants that IP(i) could not (A38V vs A67V; R55K vs R36Q). The following variants (and their count) were identified: R50W/T4M/A67T/A70T (1,210), A67V (23), A38V (9), P66A (6), R36Q/R50Q (5), V17M/V44M (5), A67S (4), R55K/R56K (3), T29I/T41I (1), S34N (1), S33P (1), Y31H (1). We observed a different relative frequency of A67T and A70T variants than expected based on a general population ExAC DNA database. We expected to detect 2.1-fold more A67T than A70T counts. However, DNA sequencing of 74 samples in this study identified 1.6-fold more A70T occurrences (46) than A67T (28). Overrepresentation of A70T may suggest its clinical significance. The A38V variant was predicted to occur 5.1-times in the population studied, but it was detected 9 times. The A67V variant was not present in the ExAC database, but it was detected in 23 patients. We detected 2 variants that did not match WT or expected variants; DNA sequencing identified them as new variants (S33P, Y31H). DNA sequencing also identified 3 new variants (R50Q, R56K, T41I) at different positions than expected. Using a few test samples, the tandem MS technique has shown its ability to distinguish between A67T and A70T. It will be applied to this patient set. IP(i) and rRT can be used together to identify and differentiate IGF-1 variants. Such an approach may provide improved estimates of variant frequencies and identify new variants. Oxford University Press 2020-05-08 /pmc/articles/PMC7208636/ http://dx.doi.org/10.1210/jendso/bvaa046.1919 Text en © Endocrine Society 2020. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Neuroendocrinology and Pituitary
Motorykin, Ievgen
McPhaul, Michael John
Clarke, Nigel J
Wu, Zengru
MON-271 Identification of IGF-1 Variants in a Clinical Study of 307,000 Specimens: Discrepancies with General Population and Novel Discoveries
title MON-271 Identification of IGF-1 Variants in a Clinical Study of 307,000 Specimens: Discrepancies with General Population and Novel Discoveries
title_full MON-271 Identification of IGF-1 Variants in a Clinical Study of 307,000 Specimens: Discrepancies with General Population and Novel Discoveries
title_fullStr MON-271 Identification of IGF-1 Variants in a Clinical Study of 307,000 Specimens: Discrepancies with General Population and Novel Discoveries
title_full_unstemmed MON-271 Identification of IGF-1 Variants in a Clinical Study of 307,000 Specimens: Discrepancies with General Population and Novel Discoveries
title_short MON-271 Identification of IGF-1 Variants in a Clinical Study of 307,000 Specimens: Discrepancies with General Population and Novel Discoveries
title_sort mon-271 identification of igf-1 variants in a clinical study of 307,000 specimens: discrepancies with general population and novel discoveries
topic Neuroendocrinology and Pituitary
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7208636/
http://dx.doi.org/10.1210/jendso/bvaa046.1919
work_keys_str_mv AT motorykinievgen mon271identificationofigf1variantsinaclinicalstudyof307000specimensdiscrepancieswithgeneralpopulationandnoveldiscoveries
AT mcphaulmichaeljohn mon271identificationofigf1variantsinaclinicalstudyof307000specimensdiscrepancieswithgeneralpopulationandnoveldiscoveries
AT clarkenigelj mon271identificationofigf1variantsinaclinicalstudyof307000specimensdiscrepancieswithgeneralpopulationandnoveldiscoveries
AT wuzengru mon271identificationofigf1variantsinaclinicalstudyof307000specimensdiscrepancieswithgeneralpopulationandnoveldiscoveries