Cargando…

SAT-422 Evaluation of the Siemens Thyroid Stimulating Immunoglobulin (TSI) Assay for Diagnosis and Prognosis of Graves’ Disease

Background: Hyperthyroidism due to Graves’ disease (GD) is an autoimmune condition caused by thyroid stimulating hormone receptor (TSHR) autoantibodies. Autoantibodies to the TSHR can stimulate or block thyroid hormone production, therefore testing specifically for stimulating antibodies would be be...

Descripción completa

Detalles Bibliográficos
Autores principales: Paul, Heather, Moledina, Nadia, Robinson, Jason, Chin, Alex, Kline, Gregory A, Sadrzadeh, Hossein
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7209416/
http://dx.doi.org/10.1210/jendso/bvaa046.387
_version_ 1783531072594640896
author Paul, Heather
Moledina, Nadia
Robinson, Jason
Chin, Alex
Kline, Gregory A
Sadrzadeh, Hossein
author_facet Paul, Heather
Moledina, Nadia
Robinson, Jason
Chin, Alex
Kline, Gregory A
Sadrzadeh, Hossein
author_sort Paul, Heather
collection PubMed
description Background: Hyperthyroidism due to Graves’ disease (GD) is an autoimmune condition caused by thyroid stimulating hormone receptor (TSHR) autoantibodies. Autoantibodies to the TSHR can stimulate or block thyroid hormone production, therefore testing specifically for stimulating antibodies would be beneficial for diagnosis of GD. Objectives: The primary objective of the first phase of this trial is to assess the diagnostic capability of the Siemens Thyroid Stimulating Immunoglobulin (TSI) immunoassay in diagnosing GD and to compare it with the Roche TSH Receptor Antibody (TRAb) assay. Design and Methods: Two hundred patients with suspected GD are being enrolled in this single-center multiphase prospective cohort study. Consenting patients undergo biochemical testing including thyroid stimulating hormone (TSH), free T3 (FT3) and T4 (FT4), TRAb and TSI measurements. GD diagnosis was confirmed by endocrinologists that were blinded to TSI results. Results: To date, 85 patients were included in the analysis, of which 66 were diagnosed with GD. For the primary analysis, all patients taking anti-thyroid drugs (ATD) at time of sample collection (n=14) were removed. The respective sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) for TSI was 98, 84, 94 and 94%, which were comparable to those generated by TRAb (98, 95, 95, and 98%). In patients with clinical findings of GD (ie. orbitopathy or goiter, n=33), both the TSI and TRAb assays had identical sensitivity and specificity at 96% and 80% respectively. In patients without orbitopathy or goiter (n=38), the TSI assay had perfect sensitivity and excellent specificity of 100% and 86% respectively (TRAb had 100% sensitivity and specificity). Sensitivity, specificity, NPV, and PPV were slightly lower for both TSI and TRAb in patients treated with ATDs compared to patients without treatment (TSI: 85, 84, 62, 95%; TRAb: 91, 95, 75, 98%). Of ten patients with GD and false negative TSI results, nine were on ATDs. Of this subset, four patients had discordant results between TSI (negative) and TRAb (positive). Notably, one of these patients had normalization of their FT3 and FT4 on the day of sample collection. Discussion and Conclusion: Based on our preliminary results, TSI is an excellent marker for diagnosing GD, particularly in untreated GD patients. The performance of the TSI assay has been comparable to the TRAb assay and correlates well with clinical findings. Discordant false negative results were only seen in patients on ATD. One potential explanation is that the TSI assay is detecting a decrease in stimulating autoantibodies when there is normalization of FT3 and FT4. Importantly, all discordant samples will be tested by a TSI bioassay to confirm diagnosis. Further patient enrollment is occurring, and prognostic assessment of these assays will soon be possible.
format Online
Article
Text
id pubmed-7209416
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-72094162020-05-13 SAT-422 Evaluation of the Siemens Thyroid Stimulating Immunoglobulin (TSI) Assay for Diagnosis and Prognosis of Graves’ Disease Paul, Heather Moledina, Nadia Robinson, Jason Chin, Alex Kline, Gregory A Sadrzadeh, Hossein J Endocr Soc Thyroid Background: Hyperthyroidism due to Graves’ disease (GD) is an autoimmune condition caused by thyroid stimulating hormone receptor (TSHR) autoantibodies. Autoantibodies to the TSHR can stimulate or block thyroid hormone production, therefore testing specifically for stimulating antibodies would be beneficial for diagnosis of GD. Objectives: The primary objective of the first phase of this trial is to assess the diagnostic capability of the Siemens Thyroid Stimulating Immunoglobulin (TSI) immunoassay in diagnosing GD and to compare it with the Roche TSH Receptor Antibody (TRAb) assay. Design and Methods: Two hundred patients with suspected GD are being enrolled in this single-center multiphase prospective cohort study. Consenting patients undergo biochemical testing including thyroid stimulating hormone (TSH), free T3 (FT3) and T4 (FT4), TRAb and TSI measurements. GD diagnosis was confirmed by endocrinologists that were blinded to TSI results. Results: To date, 85 patients were included in the analysis, of which 66 were diagnosed with GD. For the primary analysis, all patients taking anti-thyroid drugs (ATD) at time of sample collection (n=14) were removed. The respective sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) for TSI was 98, 84, 94 and 94%, which were comparable to those generated by TRAb (98, 95, 95, and 98%). In patients with clinical findings of GD (ie. orbitopathy or goiter, n=33), both the TSI and TRAb assays had identical sensitivity and specificity at 96% and 80% respectively. In patients without orbitopathy or goiter (n=38), the TSI assay had perfect sensitivity and excellent specificity of 100% and 86% respectively (TRAb had 100% sensitivity and specificity). Sensitivity, specificity, NPV, and PPV were slightly lower for both TSI and TRAb in patients treated with ATDs compared to patients without treatment (TSI: 85, 84, 62, 95%; TRAb: 91, 95, 75, 98%). Of ten patients with GD and false negative TSI results, nine were on ATDs. Of this subset, four patients had discordant results between TSI (negative) and TRAb (positive). Notably, one of these patients had normalization of their FT3 and FT4 on the day of sample collection. Discussion and Conclusion: Based on our preliminary results, TSI is an excellent marker for diagnosing GD, particularly in untreated GD patients. The performance of the TSI assay has been comparable to the TRAb assay and correlates well with clinical findings. Discordant false negative results were only seen in patients on ATD. One potential explanation is that the TSI assay is detecting a decrease in stimulating autoantibodies when there is normalization of FT3 and FT4. Importantly, all discordant samples will be tested by a TSI bioassay to confirm diagnosis. Further patient enrollment is occurring, and prognostic assessment of these assays will soon be possible. Oxford University Press 2020-05-08 /pmc/articles/PMC7209416/ http://dx.doi.org/10.1210/jendso/bvaa046.387 Text en © Endocrine Society 2020. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Thyroid
Paul, Heather
Moledina, Nadia
Robinson, Jason
Chin, Alex
Kline, Gregory A
Sadrzadeh, Hossein
SAT-422 Evaluation of the Siemens Thyroid Stimulating Immunoglobulin (TSI) Assay for Diagnosis and Prognosis of Graves’ Disease
title SAT-422 Evaluation of the Siemens Thyroid Stimulating Immunoglobulin (TSI) Assay for Diagnosis and Prognosis of Graves’ Disease
title_full SAT-422 Evaluation of the Siemens Thyroid Stimulating Immunoglobulin (TSI) Assay for Diagnosis and Prognosis of Graves’ Disease
title_fullStr SAT-422 Evaluation of the Siemens Thyroid Stimulating Immunoglobulin (TSI) Assay for Diagnosis and Prognosis of Graves’ Disease
title_full_unstemmed SAT-422 Evaluation of the Siemens Thyroid Stimulating Immunoglobulin (TSI) Assay for Diagnosis and Prognosis of Graves’ Disease
title_short SAT-422 Evaluation of the Siemens Thyroid Stimulating Immunoglobulin (TSI) Assay for Diagnosis and Prognosis of Graves’ Disease
title_sort sat-422 evaluation of the siemens thyroid stimulating immunoglobulin (tsi) assay for diagnosis and prognosis of graves’ disease
topic Thyroid
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7209416/
http://dx.doi.org/10.1210/jendso/bvaa046.387
work_keys_str_mv AT paulheather sat422evaluationofthesiemensthyroidstimulatingimmunoglobulintsiassayfordiagnosisandprognosisofgravesdisease
AT moledinanadia sat422evaluationofthesiemensthyroidstimulatingimmunoglobulintsiassayfordiagnosisandprognosisofgravesdisease
AT robinsonjason sat422evaluationofthesiemensthyroidstimulatingimmunoglobulintsiassayfordiagnosisandprognosisofgravesdisease
AT chinalex sat422evaluationofthesiemensthyroidstimulatingimmunoglobulintsiassayfordiagnosisandprognosisofgravesdisease
AT klinegregorya sat422evaluationofthesiemensthyroidstimulatingimmunoglobulintsiassayfordiagnosisandprognosisofgravesdisease
AT sadrzadehhossein sat422evaluationofthesiemensthyroidstimulatingimmunoglobulintsiassayfordiagnosisandprognosisofgravesdisease