Cargando…

Data on propylene/propane separation by the externally heat-integrated distillation column (EHIDiC) using data-driven analysis

Nine hundred data were collected from rigorously simulated EHIDiC for propylene/propane separation using the Aspen Plus-Matlab communication platform. Statistical analysis was performed to give a further understanding of EHIDiC, a highly coupled system. The input variables, integrated stages, and th...

Descripción completa

Detalles Bibliográficos
Autores principales: Qiu, Peng, Huang, Bo, Dai, Zhenghua, Wang, Fuchen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7210417/
https://www.ncbi.nlm.nih.gov/pubmed/32395576
http://dx.doi.org/10.1016/j.dib.2020.105559
_version_ 1783531270602489856
author Qiu, Peng
Huang, Bo
Dai, Zhenghua
Wang, Fuchen
author_facet Qiu, Peng
Huang, Bo
Dai, Zhenghua
Wang, Fuchen
author_sort Qiu, Peng
collection PubMed
description Nine hundred data were collected from rigorously simulated EHIDiC for propylene/propane separation using the Aspen Plus-Matlab communication platform. Statistical analysis was performed to give a further understanding of EHIDiC, a highly coupled system. The input variables, integrated stages, and the corresponding heat of two couples of external exchangers were generated stochastically in a wide range to cover the completely reasonable operation window. The results of blocks and streams in the flowsheet were calculated as the output data, including the flow rate, the temperature, and the pressure, as well as Total Annualized Cost (TAC). The data can be reused to design and optimize both the steady and dynamic schemes of EHIDiC, especially with machine learning methods. This manuscript gave a full description of collecting and analyzing of the data used in the research article “Data-driven analysis and optimization of externally heat-integrated distillation columns (EHIDiC)” [1].
format Online
Article
Text
id pubmed-7210417
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-72104172020-05-11 Data on propylene/propane separation by the externally heat-integrated distillation column (EHIDiC) using data-driven analysis Qiu, Peng Huang, Bo Dai, Zhenghua Wang, Fuchen Data Brief Chemical Engineering Nine hundred data were collected from rigorously simulated EHIDiC for propylene/propane separation using the Aspen Plus-Matlab communication platform. Statistical analysis was performed to give a further understanding of EHIDiC, a highly coupled system. The input variables, integrated stages, and the corresponding heat of two couples of external exchangers were generated stochastically in a wide range to cover the completely reasonable operation window. The results of blocks and streams in the flowsheet were calculated as the output data, including the flow rate, the temperature, and the pressure, as well as Total Annualized Cost (TAC). The data can be reused to design and optimize both the steady and dynamic schemes of EHIDiC, especially with machine learning methods. This manuscript gave a full description of collecting and analyzing of the data used in the research article “Data-driven analysis and optimization of externally heat-integrated distillation columns (EHIDiC)” [1]. Elsevier 2020-04-20 /pmc/articles/PMC7210417/ /pubmed/32395576 http://dx.doi.org/10.1016/j.dib.2020.105559 Text en © 2020 Published by Elsevier Inc. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Chemical Engineering
Qiu, Peng
Huang, Bo
Dai, Zhenghua
Wang, Fuchen
Data on propylene/propane separation by the externally heat-integrated distillation column (EHIDiC) using data-driven analysis
title Data on propylene/propane separation by the externally heat-integrated distillation column (EHIDiC) using data-driven analysis
title_full Data on propylene/propane separation by the externally heat-integrated distillation column (EHIDiC) using data-driven analysis
title_fullStr Data on propylene/propane separation by the externally heat-integrated distillation column (EHIDiC) using data-driven analysis
title_full_unstemmed Data on propylene/propane separation by the externally heat-integrated distillation column (EHIDiC) using data-driven analysis
title_short Data on propylene/propane separation by the externally heat-integrated distillation column (EHIDiC) using data-driven analysis
title_sort data on propylene/propane separation by the externally heat-integrated distillation column (ehidic) using data-driven analysis
topic Chemical Engineering
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7210417/
https://www.ncbi.nlm.nih.gov/pubmed/32395576
http://dx.doi.org/10.1016/j.dib.2020.105559
work_keys_str_mv AT qiupeng dataonpropylenepropaneseparationbytheexternallyheatintegrateddistillationcolumnehidicusingdatadrivenanalysis
AT huangbo dataonpropylenepropaneseparationbytheexternallyheatintegrateddistillationcolumnehidicusingdatadrivenanalysis
AT daizhenghua dataonpropylenepropaneseparationbytheexternallyheatintegrateddistillationcolumnehidicusingdatadrivenanalysis
AT wangfuchen dataonpropylenepropaneseparationbytheexternallyheatintegrateddistillationcolumnehidicusingdatadrivenanalysis