Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study
OBJECTIVES: The objective of this systematic review and meta-analysis study was to identify the different disinfection methods and materials and the existing evidence on their effect on properties of the different impression materials. MATERIAL AND METHODS: An electronic search of MEDLINE (PubMed),...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7211894/ https://www.ncbi.nlm.nih.gov/pubmed/32405219 http://dx.doi.org/10.1016/j.sdentj.2019.12.003 |
_version_ | 1783531535723397120 |
---|---|
author | AlZain, Sahar |
author_facet | AlZain, Sahar |
author_sort | AlZain, Sahar |
collection | PubMed |
description | OBJECTIVES: The objective of this systematic review and meta-analysis study was to identify the different disinfection methods and materials and the existing evidence on their effect on properties of the different impression materials. MATERIAL AND METHODS: An electronic search of MEDLINE (PubMed), Science Direct, and Google Scholar databases was performed to retrieve related English-language articles published between January 2000 and July 2019. Available studies with search terms such as: Impression disinfection, disinfection method, impression dimensional stability and impression wettability were used. The selected articles were reviewed by screening their titles and abstracts and full text. Finally, a total of 70 articles were considered relevant and were included in this study. RESULTS: Extensive studies were conducted to determine the effect of the different disinfection methods and materials on the properties of the different impression materials such as dimensional stability, wettability and surface roughness. While some studies reported significant changes in the properties of the impression materials, others reported either no changes or minor insignificant effects. CONCLUSIONS: Some studies reported significant changes in the properties of the impression materials as a result of using different disinfection methods, whereas others reported either minor insignificant or no changes. Although the findings of the studies were controversial, care should be taken to avoid distortion of impressions and loss of their surface details that can adversely affect the fitting accuracy of the restorations. Therefore, better designed and standardized studies are needed to evaluate the effect of different commonly used disinfectants on properties of impression materials. Moreover, manufacturers should be encouraged to recommend specific disinfection methods and materials for disinfecting the impression materials to ensure their optimal accuracy. |
format | Online Article Text |
id | pubmed-7211894 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-72118942020-05-13 Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study AlZain, Sahar Saudi Dent J Review Article OBJECTIVES: The objective of this systematic review and meta-analysis study was to identify the different disinfection methods and materials and the existing evidence on their effect on properties of the different impression materials. MATERIAL AND METHODS: An electronic search of MEDLINE (PubMed), Science Direct, and Google Scholar databases was performed to retrieve related English-language articles published between January 2000 and July 2019. Available studies with search terms such as: Impression disinfection, disinfection method, impression dimensional stability and impression wettability were used. The selected articles were reviewed by screening their titles and abstracts and full text. Finally, a total of 70 articles were considered relevant and were included in this study. RESULTS: Extensive studies were conducted to determine the effect of the different disinfection methods and materials on the properties of the different impression materials such as dimensional stability, wettability and surface roughness. While some studies reported significant changes in the properties of the impression materials, others reported either no changes or minor insignificant effects. CONCLUSIONS: Some studies reported significant changes in the properties of the impression materials as a result of using different disinfection methods, whereas others reported either minor insignificant or no changes. Although the findings of the studies were controversial, care should be taken to avoid distortion of impressions and loss of their surface details that can adversely affect the fitting accuracy of the restorations. Therefore, better designed and standardized studies are needed to evaluate the effect of different commonly used disinfectants on properties of impression materials. Moreover, manufacturers should be encouraged to recommend specific disinfection methods and materials for disinfecting the impression materials to ensure their optimal accuracy. Elsevier 2020-05 2019-12-23 /pmc/articles/PMC7211894/ /pubmed/32405219 http://dx.doi.org/10.1016/j.sdentj.2019.12.003 Text en © 2019 The Author http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Review Article AlZain, Sahar Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study |
title | Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study |
title_full | Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study |
title_fullStr | Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study |
title_full_unstemmed | Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study |
title_short | Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study |
title_sort | effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: a systematic review and meta-analysis study |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7211894/ https://www.ncbi.nlm.nih.gov/pubmed/32405219 http://dx.doi.org/10.1016/j.sdentj.2019.12.003 |
work_keys_str_mv | AT alzainsahar effectofchemicalmicrowaveirradiationsteamautoclaveultravioletlightradiationozoneandelectrolyzedoxidizingwaterdisinfectiononpropertiesofimpressionmaterialsasystematicreviewandmetaanalysisstudy |