Cargando…
Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report
BACKGROUND: There is only limited experience with wearable cardioverter-defibrillators (WCD) in pediatric patients. We report on the successful application of a WCD in an adolescent patient with hypertrophic cardiomyopathy and myocardial bridging. CASE PRESENTATION: A 15-year-old girl presented with...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7212673/ https://www.ncbi.nlm.nih.gov/pubmed/32393291 http://dx.doi.org/10.1186/s12887-020-02113-w |
_version_ | 1783531657175760896 |
---|---|
author | Kurath-Koller, Stefan Sallmon, Hannes Scherr, Daniel Bisping, Egbert Burmas, Ante Knez, Igor Koestenberger, Martin |
author_facet | Kurath-Koller, Stefan Sallmon, Hannes Scherr, Daniel Bisping, Egbert Burmas, Ante Knez, Igor Koestenberger, Martin |
author_sort | Kurath-Koller, Stefan |
collection | PubMed |
description | BACKGROUND: There is only limited experience with wearable cardioverter-defibrillators (WCD) in pediatric patients. We report on the successful application of a WCD in an adolescent patient with hypertrophic cardiomyopathy and myocardial bridging. CASE PRESENTATION: A 15-year-old girl presented with a history of recurrent syncope, dyspnea, and vertigo with exercise. Diagnostic work-up revealed non-obstructive hypertrophic cardiomyopathy and signs of myocardial ischemia with exercise. Given this high-risk constellation, the patient was scheduled for prophylactic implantation of an implantable cardioverter-defibrillator (ICD). One month after initial presentation and days prior to the planned ICD implantation, the patient collapsed during an episode of sustained ventricular tachycardia (VT) while running. VT was terminated by WCD shock delivery. Following this event, computerized tomography scan revealed myocardial bridging of the left anterior descending coronary artery causing a 90% stenosis in systole. After coronary surgery, life threatening arrhythmias have not recurred, but due to progressive heart failure, the patient underwent successful heart transplantation after 2 years. CONCLUSIONS: The reported case highlights the importance and applicability of WCDs and the potentially malign nature of myocardial bridging in pediatric high-risk patients. |
format | Online Article Text |
id | pubmed-7212673 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-72126732020-05-18 Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report Kurath-Koller, Stefan Sallmon, Hannes Scherr, Daniel Bisping, Egbert Burmas, Ante Knez, Igor Koestenberger, Martin BMC Pediatr Case Report BACKGROUND: There is only limited experience with wearable cardioverter-defibrillators (WCD) in pediatric patients. We report on the successful application of a WCD in an adolescent patient with hypertrophic cardiomyopathy and myocardial bridging. CASE PRESENTATION: A 15-year-old girl presented with a history of recurrent syncope, dyspnea, and vertigo with exercise. Diagnostic work-up revealed non-obstructive hypertrophic cardiomyopathy and signs of myocardial ischemia with exercise. Given this high-risk constellation, the patient was scheduled for prophylactic implantation of an implantable cardioverter-defibrillator (ICD). One month after initial presentation and days prior to the planned ICD implantation, the patient collapsed during an episode of sustained ventricular tachycardia (VT) while running. VT was terminated by WCD shock delivery. Following this event, computerized tomography scan revealed myocardial bridging of the left anterior descending coronary artery causing a 90% stenosis in systole. After coronary surgery, life threatening arrhythmias have not recurred, but due to progressive heart failure, the patient underwent successful heart transplantation after 2 years. CONCLUSIONS: The reported case highlights the importance and applicability of WCDs and the potentially malign nature of myocardial bridging in pediatric high-risk patients. BioMed Central 2020-05-11 /pmc/articles/PMC7212673/ /pubmed/32393291 http://dx.doi.org/10.1186/s12887-020-02113-w Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Case Report Kurath-Koller, Stefan Sallmon, Hannes Scherr, Daniel Bisping, Egbert Burmas, Ante Knez, Igor Koestenberger, Martin Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report |
title | Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report |
title_full | Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report |
title_fullStr | Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report |
title_full_unstemmed | Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report |
title_short | Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report |
title_sort | wearable cardioverter-defibrillator as bridging to icd in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7212673/ https://www.ncbi.nlm.nih.gov/pubmed/32393291 http://dx.doi.org/10.1186/s12887-020-02113-w |
work_keys_str_mv | AT kurathkollerstefan wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport AT sallmonhannes wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport AT scherrdaniel wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport AT bispingegbert wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport AT burmasante wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport AT knezigor wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport AT koestenbergermartin wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport |