Cargando…

Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report

BACKGROUND: There is only limited experience with wearable cardioverter-defibrillators (WCD) in pediatric patients. We report on the successful application of a WCD in an adolescent patient with hypertrophic cardiomyopathy and myocardial bridging. CASE PRESENTATION: A 15-year-old girl presented with...

Descripción completa

Detalles Bibliográficos
Autores principales: Kurath-Koller, Stefan, Sallmon, Hannes, Scherr, Daniel, Bisping, Egbert, Burmas, Ante, Knez, Igor, Koestenberger, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7212673/
https://www.ncbi.nlm.nih.gov/pubmed/32393291
http://dx.doi.org/10.1186/s12887-020-02113-w
_version_ 1783531657175760896
author Kurath-Koller, Stefan
Sallmon, Hannes
Scherr, Daniel
Bisping, Egbert
Burmas, Ante
Knez, Igor
Koestenberger, Martin
author_facet Kurath-Koller, Stefan
Sallmon, Hannes
Scherr, Daniel
Bisping, Egbert
Burmas, Ante
Knez, Igor
Koestenberger, Martin
author_sort Kurath-Koller, Stefan
collection PubMed
description BACKGROUND: There is only limited experience with wearable cardioverter-defibrillators (WCD) in pediatric patients. We report on the successful application of a WCD in an adolescent patient with hypertrophic cardiomyopathy and myocardial bridging. CASE PRESENTATION: A 15-year-old girl presented with a history of recurrent syncope, dyspnea, and vertigo with exercise. Diagnostic work-up revealed non-obstructive hypertrophic cardiomyopathy and signs of myocardial ischemia with exercise. Given this high-risk constellation, the patient was scheduled for prophylactic implantation of an implantable cardioverter-defibrillator (ICD). One month after initial presentation and days prior to the planned ICD implantation, the patient collapsed during an episode of sustained ventricular tachycardia (VT) while running. VT was terminated by WCD shock delivery. Following this event, computerized tomography scan revealed myocardial bridging of the left anterior descending coronary artery causing a 90% stenosis in systole. After coronary surgery, life threatening arrhythmias have not recurred, but due to progressive heart failure, the patient underwent successful heart transplantation after 2 years. CONCLUSIONS: The reported case highlights the importance and applicability of WCDs and the potentially malign nature of myocardial bridging in pediatric high-risk patients.
format Online
Article
Text
id pubmed-7212673
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-72126732020-05-18 Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report Kurath-Koller, Stefan Sallmon, Hannes Scherr, Daniel Bisping, Egbert Burmas, Ante Knez, Igor Koestenberger, Martin BMC Pediatr Case Report BACKGROUND: There is only limited experience with wearable cardioverter-defibrillators (WCD) in pediatric patients. We report on the successful application of a WCD in an adolescent patient with hypertrophic cardiomyopathy and myocardial bridging. CASE PRESENTATION: A 15-year-old girl presented with a history of recurrent syncope, dyspnea, and vertigo with exercise. Diagnostic work-up revealed non-obstructive hypertrophic cardiomyopathy and signs of myocardial ischemia with exercise. Given this high-risk constellation, the patient was scheduled for prophylactic implantation of an implantable cardioverter-defibrillator (ICD). One month after initial presentation and days prior to the planned ICD implantation, the patient collapsed during an episode of sustained ventricular tachycardia (VT) while running. VT was terminated by WCD shock delivery. Following this event, computerized tomography scan revealed myocardial bridging of the left anterior descending coronary artery causing a 90% stenosis in systole. After coronary surgery, life threatening arrhythmias have not recurred, but due to progressive heart failure, the patient underwent successful heart transplantation after 2 years. CONCLUSIONS: The reported case highlights the importance and applicability of WCDs and the potentially malign nature of myocardial bridging in pediatric high-risk patients. BioMed Central 2020-05-11 /pmc/articles/PMC7212673/ /pubmed/32393291 http://dx.doi.org/10.1186/s12887-020-02113-w Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Case Report
Kurath-Koller, Stefan
Sallmon, Hannes
Scherr, Daniel
Bisping, Egbert
Burmas, Ante
Knez, Igor
Koestenberger, Martin
Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report
title Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report
title_full Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report
title_fullStr Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report
title_full_unstemmed Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report
title_short Wearable cardioverter-defibrillator as bridging to ICD in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report
title_sort wearable cardioverter-defibrillator as bridging to icd in pediatric hypertrophic cardiomyopathy with myocardial bridging – a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7212673/
https://www.ncbi.nlm.nih.gov/pubmed/32393291
http://dx.doi.org/10.1186/s12887-020-02113-w
work_keys_str_mv AT kurathkollerstefan wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport
AT sallmonhannes wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport
AT scherrdaniel wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport
AT bispingegbert wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport
AT burmasante wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport
AT knezigor wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport
AT koestenbergermartin wearablecardioverterdefibrillatorasbridgingtoicdinpediatrichypertrophiccardiomyopathywithmyocardialbridgingacasereport