Cargando…

RADI-39. EFFECT OF RIND-BASED DOSIMETRIC TECHNIQUES FOR SCALP DOSE REDUCTION IN BRAIN IRRADIATION

OBJECTIVE: Radiation-induced alopecia is an unwanted side effect causing permanent cosmetic distress if hair regrowth does not occur. Rind-based techniques can effectively control dosimetric spread. We evaluated this technique to reduce scalp dose and alopecia while maintaining tumor coverage. METHO...

Descripción completa

Detalles Bibliográficos
Autores principales: No, Diana, Julie, Diana, Knisely, Jonathan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7213161/
http://dx.doi.org/10.1093/noajnl/vdz014.130
_version_ 1783531743337250816
author No, Diana
Julie, Diana
Knisely, Jonathan
author_facet No, Diana
Julie, Diana
Knisely, Jonathan
author_sort No, Diana
collection PubMed
description OBJECTIVE: Radiation-induced alopecia is an unwanted side effect causing permanent cosmetic distress if hair regrowth does not occur. Rind-based techniques can effectively control dosimetric spread. We evaluated this technique to reduce scalp dose and alopecia while maintaining tumor coverage. METHODS: Ten consecutive brain tumor plans were retrospectively evaluated. All planning tumor volume (PTV) margins were ≤ 15.0mm from the skin surface. Departmental guidelines for fractionation were followed, with minimum 95% PTV coverage receiving 100% dose. Fractionation variation was accounted for with biologically effective dose calculation (alpha/beta=2). Rind structures encompassed 5mm depth from scalp surface; upper dose limits were customized to minimum values without PTV coverage compromise. Standard comparative plans using identical criteria, without rind structures, were calculated. Scalp dose evaluation was defined for tissue from skin to 5mm depth. Paired T-tests were used for comparative evaluation. RESULTS: Median age: 58 (range 27–85); 70% female (n=7). Histologies included gliomas (n=7) and meningiomas (n=3). Median PTV distance to skin surface: 13.5mm (range 8.0–15.0). Median PTV minimum and mean dose for rind-based plans: 88.63% (range 73.14–95.2) and 104.39% (range 102.07–107.38) of prescription and 90.90% (range 68.64–98.21) and 103.02% (range 101.91–107.04) for standard plans, respectively. Statistically significant reduction in scalp maximum and mean dose of 19.65% (p=2.72E(-06)) and 0.48% (p=0.007), respectively, was seen with rind-based planning. Scalp volume receiving 1000cGy-equivalent increased 6.7cc using rind-based techniques, although insignificant (p=0.33). Volume receiving 1500cGy-equivalent was significantly reduced 3.88cc (p=0.03) using rind-based techniques. With median 28.5 day follow-up, of 5 patients treated using rind-based techniques, 40% (n=2) exhibited acute alopecia compared to 100% of those treated with standard plans. CONCLUSION: Rind-based dosimetric techniques exhibit significant reduction of scalp dose in brain irradiation. 60% of patients treated using this technique experienced no alopecia, versus 0% receiving standard treatment. Further investigation is warranted to better evaluate correlation.
format Online
Article
Text
id pubmed-7213161
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-72131612020-07-07 RADI-39. EFFECT OF RIND-BASED DOSIMETRIC TECHNIQUES FOR SCALP DOSE REDUCTION IN BRAIN IRRADIATION No, Diana Julie, Diana Knisely, Jonathan Neurooncol Adv Abstracts OBJECTIVE: Radiation-induced alopecia is an unwanted side effect causing permanent cosmetic distress if hair regrowth does not occur. Rind-based techniques can effectively control dosimetric spread. We evaluated this technique to reduce scalp dose and alopecia while maintaining tumor coverage. METHODS: Ten consecutive brain tumor plans were retrospectively evaluated. All planning tumor volume (PTV) margins were ≤ 15.0mm from the skin surface. Departmental guidelines for fractionation were followed, with minimum 95% PTV coverage receiving 100% dose. Fractionation variation was accounted for with biologically effective dose calculation (alpha/beta=2). Rind structures encompassed 5mm depth from scalp surface; upper dose limits were customized to minimum values without PTV coverage compromise. Standard comparative plans using identical criteria, without rind structures, were calculated. Scalp dose evaluation was defined for tissue from skin to 5mm depth. Paired T-tests were used for comparative evaluation. RESULTS: Median age: 58 (range 27–85); 70% female (n=7). Histologies included gliomas (n=7) and meningiomas (n=3). Median PTV distance to skin surface: 13.5mm (range 8.0–15.0). Median PTV minimum and mean dose for rind-based plans: 88.63% (range 73.14–95.2) and 104.39% (range 102.07–107.38) of prescription and 90.90% (range 68.64–98.21) and 103.02% (range 101.91–107.04) for standard plans, respectively. Statistically significant reduction in scalp maximum and mean dose of 19.65% (p=2.72E(-06)) and 0.48% (p=0.007), respectively, was seen with rind-based planning. Scalp volume receiving 1000cGy-equivalent increased 6.7cc using rind-based techniques, although insignificant (p=0.33). Volume receiving 1500cGy-equivalent was significantly reduced 3.88cc (p=0.03) using rind-based techniques. With median 28.5 day follow-up, of 5 patients treated using rind-based techniques, 40% (n=2) exhibited acute alopecia compared to 100% of those treated with standard plans. CONCLUSION: Rind-based dosimetric techniques exhibit significant reduction of scalp dose in brain irradiation. 60% of patients treated using this technique experienced no alopecia, versus 0% receiving standard treatment. Further investigation is warranted to better evaluate correlation. Oxford University Press 2019-08-12 /pmc/articles/PMC7213161/ http://dx.doi.org/10.1093/noajnl/vdz014.130 Text en © The Author(s) 2019. Published by Oxford University Press, the Society for Neuro-Oncology and the European Association of Neuro-Oncology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Abstracts
No, Diana
Julie, Diana
Knisely, Jonathan
RADI-39. EFFECT OF RIND-BASED DOSIMETRIC TECHNIQUES FOR SCALP DOSE REDUCTION IN BRAIN IRRADIATION
title RADI-39. EFFECT OF RIND-BASED DOSIMETRIC TECHNIQUES FOR SCALP DOSE REDUCTION IN BRAIN IRRADIATION
title_full RADI-39. EFFECT OF RIND-BASED DOSIMETRIC TECHNIQUES FOR SCALP DOSE REDUCTION IN BRAIN IRRADIATION
title_fullStr RADI-39. EFFECT OF RIND-BASED DOSIMETRIC TECHNIQUES FOR SCALP DOSE REDUCTION IN BRAIN IRRADIATION
title_full_unstemmed RADI-39. EFFECT OF RIND-BASED DOSIMETRIC TECHNIQUES FOR SCALP DOSE REDUCTION IN BRAIN IRRADIATION
title_short RADI-39. EFFECT OF RIND-BASED DOSIMETRIC TECHNIQUES FOR SCALP DOSE REDUCTION IN BRAIN IRRADIATION
title_sort radi-39. effect of rind-based dosimetric techniques for scalp dose reduction in brain irradiation
topic Abstracts
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7213161/
http://dx.doi.org/10.1093/noajnl/vdz014.130
work_keys_str_mv AT nodiana radi39effectofrindbaseddosimetrictechniquesforscalpdosereductioninbrainirradiation
AT juliediana radi39effectofrindbaseddosimetrictechniquesforscalpdosereductioninbrainirradiation
AT kniselyjonathan radi39effectofrindbaseddosimetrictechniquesforscalpdosereductioninbrainirradiation