Cargando…

Personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography

No study has evaluated the impact of different iodinated contrast media on coronary contrast enhancement, using an injection protocol according to body surface area (BSA). Thus, the present study aimed to examine the usefulness and safety of personalized application of different iodine concentration...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Meng, Hao, Panpan, Jiang, Chenyu, Hao, Guoxiang, Li, Bin, Hu, Peixin, Chen, Qingjie, Chen, Yuguo, Zhang, Aifeng, Zhang, Yun, Liu, Yanping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7214158/
https://www.ncbi.nlm.nih.gov/pubmed/32227625
http://dx.doi.org/10.1111/jcmm.15196
_version_ 1783531914993336320
author Zhang, Meng
Hao, Panpan
Jiang, Chenyu
Hao, Guoxiang
Li, Bin
Hu, Peixin
Chen, Qingjie
Chen, Yuguo
Zhang, Aifeng
Zhang, Yun
Liu, Yanping
author_facet Zhang, Meng
Hao, Panpan
Jiang, Chenyu
Hao, Guoxiang
Li, Bin
Hu, Peixin
Chen, Qingjie
Chen, Yuguo
Zhang, Aifeng
Zhang, Yun
Liu, Yanping
author_sort Zhang, Meng
collection PubMed
description No study has evaluated the impact of different iodinated contrast media on coronary contrast enhancement, using an injection protocol according to body surface area (BSA). Thus, the present study aimed to examine the usefulness and safety of personalized application of different iodine concentrations of contrast media in coronary computed tomographic (CT) angiography with a 2nd dual‐source CT scanner in eliminating differences in coronary contrast enhancement based on a BSA‐adapted injection protocol of contrast media. A total of 270 enrolled participants were randomly assigned to three groups: ioversol 320, ioversol 350 and iopromide 370 (n = 90 per group). The three groups were administered contrast media at a BSA‐adjusted volume and flow rate with a fixed injection time of 15 seconds, and they subsequently received a 30‐mL saline flush. All patients were scanned with a prospective electrocardiogram‐gated protocol in a craniocaudal direction using a second‐generation 128‐slice dual‐source CT system. The three iodinated contrast media used in coronary CT angiography exhibited similar diagnostic quality and safety. No significant differences were found in the contrast enhancement degrees, image quality scores, radiation doses and incidences of adverse effects among the three groups. The three contrast media used in coronary CT angiography with 320, 350 and 370 mg/mL iodine, respectively, have comparable diagnostic quality and safety. However, more large‐scale, multinational, multi‐centre and prospective trials are warranted.
format Online
Article
Text
id pubmed-7214158
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-72141582020-05-13 Personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography Zhang, Meng Hao, Panpan Jiang, Chenyu Hao, Guoxiang Li, Bin Hu, Peixin Chen, Qingjie Chen, Yuguo Zhang, Aifeng Zhang, Yun Liu, Yanping J Cell Mol Med Original Articles No study has evaluated the impact of different iodinated contrast media on coronary contrast enhancement, using an injection protocol according to body surface area (BSA). Thus, the present study aimed to examine the usefulness and safety of personalized application of different iodine concentrations of contrast media in coronary computed tomographic (CT) angiography with a 2nd dual‐source CT scanner in eliminating differences in coronary contrast enhancement based on a BSA‐adapted injection protocol of contrast media. A total of 270 enrolled participants were randomly assigned to three groups: ioversol 320, ioversol 350 and iopromide 370 (n = 90 per group). The three groups were administered contrast media at a BSA‐adjusted volume and flow rate with a fixed injection time of 15 seconds, and they subsequently received a 30‐mL saline flush. All patients were scanned with a prospective electrocardiogram‐gated protocol in a craniocaudal direction using a second‐generation 128‐slice dual‐source CT system. The three iodinated contrast media used in coronary CT angiography exhibited similar diagnostic quality and safety. No significant differences were found in the contrast enhancement degrees, image quality scores, radiation doses and incidences of adverse effects among the three groups. The three contrast media used in coronary CT angiography with 320, 350 and 370 mg/mL iodine, respectively, have comparable diagnostic quality and safety. However, more large‐scale, multinational, multi‐centre and prospective trials are warranted. John Wiley and Sons Inc. 2020-03-30 2020-05 /pmc/articles/PMC7214158/ /pubmed/32227625 http://dx.doi.org/10.1111/jcmm.15196 Text en © 2020 The Authors. Journal of Cellular and Molecular Medicine published by Foundation for Cellular and Molecular Medicine and John Wiley & Sons Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Zhang, Meng
Hao, Panpan
Jiang, Chenyu
Hao, Guoxiang
Li, Bin
Hu, Peixin
Chen, Qingjie
Chen, Yuguo
Zhang, Aifeng
Zhang, Yun
Liu, Yanping
Personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography
title Personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography
title_full Personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography
title_fullStr Personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography
title_full_unstemmed Personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography
title_short Personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography
title_sort personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7214158/
https://www.ncbi.nlm.nih.gov/pubmed/32227625
http://dx.doi.org/10.1111/jcmm.15196
work_keys_str_mv AT zhangmeng personalizedapplicationofthreedifferentconcentrationsofiodinatedcontrastmediaincoronarycomputedtomographyangiography
AT haopanpan personalizedapplicationofthreedifferentconcentrationsofiodinatedcontrastmediaincoronarycomputedtomographyangiography
AT jiangchenyu personalizedapplicationofthreedifferentconcentrationsofiodinatedcontrastmediaincoronarycomputedtomographyangiography
AT haoguoxiang personalizedapplicationofthreedifferentconcentrationsofiodinatedcontrastmediaincoronarycomputedtomographyangiography
AT libin personalizedapplicationofthreedifferentconcentrationsofiodinatedcontrastmediaincoronarycomputedtomographyangiography
AT hupeixin personalizedapplicationofthreedifferentconcentrationsofiodinatedcontrastmediaincoronarycomputedtomographyangiography
AT chenqingjie personalizedapplicationofthreedifferentconcentrationsofiodinatedcontrastmediaincoronarycomputedtomographyangiography
AT chenyuguo personalizedapplicationofthreedifferentconcentrationsofiodinatedcontrastmediaincoronarycomputedtomographyangiography
AT zhangaifeng personalizedapplicationofthreedifferentconcentrationsofiodinatedcontrastmediaincoronarycomputedtomographyangiography
AT zhangyun personalizedapplicationofthreedifferentconcentrationsofiodinatedcontrastmediaincoronarycomputedtomographyangiography
AT liuyanping personalizedapplicationofthreedifferentconcentrationsofiodinatedcontrastmediaincoronarycomputedtomographyangiography