Cargando…
Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse
To understand the physical demands of sexual intercourse, it is necessary to monitor the kinematic parameters of this activity using relatively non-invasive technology. The aims of this study are to analyze the validity and reliability of an inertial device for monitoring the range of motion at the...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7216012/ https://www.ncbi.nlm.nih.gov/pubmed/32331224 http://dx.doi.org/10.3390/ijerph17082884 |
_version_ | 1783532320787005440 |
---|---|
author | Oliva-Lozano, José M. Martín-Fuentes, Isabel Muyor, José M. |
author_facet | Oliva-Lozano, José M. Martín-Fuentes, Isabel Muyor, José M. |
author_sort | Oliva-Lozano, José M. |
collection | PubMed |
description | To understand the physical demands of sexual intercourse, it is necessary to monitor the kinematic parameters of this activity using relatively non-invasive technology. The aims of this study are to analyze the validity and reliability of an inertial device for monitoring the range of motion at the pelvis during simulated intercourse and compare the range of motion (ROM). Twenty-six adults were monitored during intercourse using an inertial device (WIMU) and a motion capture system (gold standard) in a test that consisted of 4 sets of 20 simulated in–out cycles (IOC) in missionary and cowgirl positions. Men and women were tested separately in a laboratory setting for simulated intercourse aims. There were no differences between the WIMU and the gold standard system at fast pace (p > 0.05), whereas there were differences at slow pace (~2.04°; p ≤ 0.05; d = 0.17). Intraclass correlation coefficients (ICCs) for the relationship between systems was very close to 1 at both paces (slow: 0.981; fast: 0.998). The test–retest reliability analysis did not show any difference between sets of measurements. In conclusion, WIMU could be considered as a valid and reliable device for IOC range of motion monitoring during sexual intercourse in missionary and cowgirl positions. |
format | Online Article Text |
id | pubmed-7216012 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-72160122020-05-22 Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse Oliva-Lozano, José M. Martín-Fuentes, Isabel Muyor, José M. Int J Environ Res Public Health Article To understand the physical demands of sexual intercourse, it is necessary to monitor the kinematic parameters of this activity using relatively non-invasive technology. The aims of this study are to analyze the validity and reliability of an inertial device for monitoring the range of motion at the pelvis during simulated intercourse and compare the range of motion (ROM). Twenty-six adults were monitored during intercourse using an inertial device (WIMU) and a motion capture system (gold standard) in a test that consisted of 4 sets of 20 simulated in–out cycles (IOC) in missionary and cowgirl positions. Men and women were tested separately in a laboratory setting for simulated intercourse aims. There were no differences between the WIMU and the gold standard system at fast pace (p > 0.05), whereas there were differences at slow pace (~2.04°; p ≤ 0.05; d = 0.17). Intraclass correlation coefficients (ICCs) for the relationship between systems was very close to 1 at both paces (slow: 0.981; fast: 0.998). The test–retest reliability analysis did not show any difference between sets of measurements. In conclusion, WIMU could be considered as a valid and reliable device for IOC range of motion monitoring during sexual intercourse in missionary and cowgirl positions. MDPI 2020-04-22 2020-04 /pmc/articles/PMC7216012/ /pubmed/32331224 http://dx.doi.org/10.3390/ijerph17082884 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Oliva-Lozano, José M. Martín-Fuentes, Isabel Muyor, José M. Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse |
title | Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse |
title_full | Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse |
title_fullStr | Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse |
title_full_unstemmed | Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse |
title_short | Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse |
title_sort | validity and reliability of a new inertial device for monitoring range of motion at the pelvis during sexual intercourse |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7216012/ https://www.ncbi.nlm.nih.gov/pubmed/32331224 http://dx.doi.org/10.3390/ijerph17082884 |
work_keys_str_mv | AT olivalozanojosem validityandreliabilityofanewinertialdeviceformonitoringrangeofmotionatthepelvisduringsexualintercourse AT martinfuentesisabel validityandreliabilityofanewinertialdeviceformonitoringrangeofmotionatthepelvisduringsexualintercourse AT muyorjosem validityandreliabilityofanewinertialdeviceformonitoringrangeofmotionatthepelvisduringsexualintercourse |