Cargando…

Case Study: Safety Assessment of Plant Layout between Ethylene Storage Tanks and Process Equipment According to Capacity and Weather Conditions

In a chemical plant, even if an explosion occurs in a storage tank that handles flammable materials, the minimum separation distance is applied in a way to prevent chain explosion. This is because when an explosion occurs in a storage tank, thermal radiation affects nearby process equipment and caus...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Jae-Young, Byeon, Sang-Hoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7216264/
https://www.ncbi.nlm.nih.gov/pubmed/32326184
http://dx.doi.org/10.3390/ijerph17082849
_version_ 1783532378721878016
author Choi, Jae-Young
Byeon, Sang-Hoon
author_facet Choi, Jae-Young
Byeon, Sang-Hoon
author_sort Choi, Jae-Young
collection PubMed
description In a chemical plant, even if an explosion occurs in a storage tank that handles flammable materials, the minimum separation distance is applied in a way to prevent chain explosion. This is because when an explosion occurs in a storage tank, thermal radiation affects nearby process equipment and causes a chain explosion. The separation distance between storage tanks and process equipment in a chemical plant depends on the global engineering guidelines PIP (Process Industry Practice) PNE00003 and GAPS (Global Asset Protection Services) GAP.2.5.2. However, there is a limitation in the global engineering guidelines that provide only a consistent separation distance according to the item types without considering the storage capacity and climatic conditions around the storage tank. This study analyzed the distance of thermal radiation (up to 37.5 kW/m(2)) according to the capacity of ethylene storage tank and climatic conditions by utilizing the Phast (DNV GL), which is widely used as a tool for quantitative risk analysis. The accident scenario was applied using the U.S. EPA (Environment Protection Agency)’s worst leakage accident scenario, considering climate variables, air temperature, wind speed, and atmospheric stability. In the simulation, atmospheric stability did not affect the radius of thermal radiation. Moreover, the thermal radiation tended to increase with increase in wind speed in the ambient condition and winter, but not in summer. Because both PIP PNE00003 and GAP.2.5.2 yield consistent separation distances without considering storage capacity and weather conditions, quantitative risk analysis of the results of thermal radiation is necessary to ensure safety.
format Online
Article
Text
id pubmed-7216264
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72162642020-05-22 Case Study: Safety Assessment of Plant Layout between Ethylene Storage Tanks and Process Equipment According to Capacity and Weather Conditions Choi, Jae-Young Byeon, Sang-Hoon Int J Environ Res Public Health Article In a chemical plant, even if an explosion occurs in a storage tank that handles flammable materials, the minimum separation distance is applied in a way to prevent chain explosion. This is because when an explosion occurs in a storage tank, thermal radiation affects nearby process equipment and causes a chain explosion. The separation distance between storage tanks and process equipment in a chemical plant depends on the global engineering guidelines PIP (Process Industry Practice) PNE00003 and GAPS (Global Asset Protection Services) GAP.2.5.2. However, there is a limitation in the global engineering guidelines that provide only a consistent separation distance according to the item types without considering the storage capacity and climatic conditions around the storage tank. This study analyzed the distance of thermal radiation (up to 37.5 kW/m(2)) according to the capacity of ethylene storage tank and climatic conditions by utilizing the Phast (DNV GL), which is widely used as a tool for quantitative risk analysis. The accident scenario was applied using the U.S. EPA (Environment Protection Agency)’s worst leakage accident scenario, considering climate variables, air temperature, wind speed, and atmospheric stability. In the simulation, atmospheric stability did not affect the radius of thermal radiation. Moreover, the thermal radiation tended to increase with increase in wind speed in the ambient condition and winter, but not in summer. Because both PIP PNE00003 and GAP.2.5.2 yield consistent separation distances without considering storage capacity and weather conditions, quantitative risk analysis of the results of thermal radiation is necessary to ensure safety. MDPI 2020-04-21 2020-04 /pmc/articles/PMC7216264/ /pubmed/32326184 http://dx.doi.org/10.3390/ijerph17082849 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Choi, Jae-Young
Byeon, Sang-Hoon
Case Study: Safety Assessment of Plant Layout between Ethylene Storage Tanks and Process Equipment According to Capacity and Weather Conditions
title Case Study: Safety Assessment of Plant Layout between Ethylene Storage Tanks and Process Equipment According to Capacity and Weather Conditions
title_full Case Study: Safety Assessment of Plant Layout between Ethylene Storage Tanks and Process Equipment According to Capacity and Weather Conditions
title_fullStr Case Study: Safety Assessment of Plant Layout between Ethylene Storage Tanks and Process Equipment According to Capacity and Weather Conditions
title_full_unstemmed Case Study: Safety Assessment of Plant Layout between Ethylene Storage Tanks and Process Equipment According to Capacity and Weather Conditions
title_short Case Study: Safety Assessment of Plant Layout between Ethylene Storage Tanks and Process Equipment According to Capacity and Weather Conditions
title_sort case study: safety assessment of plant layout between ethylene storage tanks and process equipment according to capacity and weather conditions
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7216264/
https://www.ncbi.nlm.nih.gov/pubmed/32326184
http://dx.doi.org/10.3390/ijerph17082849
work_keys_str_mv AT choijaeyoung casestudysafetyassessmentofplantlayoutbetweenethylenestoragetanksandprocessequipmentaccordingtocapacityandweatherconditions
AT byeonsanghoon casestudysafetyassessmentofplantlayoutbetweenethylenestoragetanksandprocessequipmentaccordingtocapacityandweatherconditions