Fine-tuning the use of a skin prick test device
BACKGROUND: Skin prick tests (SPTs) are the gold standard for the diagnosis of IgE-mediated allergic diseases. Newly introduced devices have different results in performance. This study aimed to provide data for sensitivity, reproducibility, and acceptability of a new SPT device by using different t...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
World Allergy Organization
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7218071/ https://www.ncbi.nlm.nih.gov/pubmed/32419899 http://dx.doi.org/10.1016/j.waojou.2020.100122 |
_version_ | 1783532720238886912 |
---|---|
author | Kahveci, Melike Karabulut, Erdem Soyer, Ozge Sahiner, Umit Murat Buyuktiryaki, Betul Sekerel, Bulent Enis |
author_facet | Kahveci, Melike Karabulut, Erdem Soyer, Ozge Sahiner, Umit Murat Buyuktiryaki, Betul Sekerel, Bulent Enis |
author_sort | Kahveci, Melike |
collection | PubMed |
description | BACKGROUND: Skin prick tests (SPTs) are the gold standard for the diagnosis of IgE-mediated allergic diseases. Newly introduced devices have different results in performance. This study aimed to provide data for sensitivity, reproducibility, and acceptability of a new SPT device by using different techniques. METHODS: The study was conducted in 4 sections. Different application techniques were evaluated. In the first section, a drop of histamine/saline was put by vial (V). In the second section, it was taken from a well via the test device (W). ALK® Lancet served as a reference in both sections. The techniques were as follows; 1) apply vertical pressure (VP/WP), 2) apply vertical pressure and rotate 90° clockwise (VC/WC), 3) apply vertical pressure and rotate 90° clockwise and then counter-clockwise (VCC/WCC). Pain assessment was performed by using the Wong-Baker FACES Pain Rating Scale. Different histamine concentrations were transferred from the well by the Oryum device and applied as WC in section 3. Lancet and Oryum-WP were compared in terms of time and allergen adequacy in section 4. RESULTS: In the first section the sensitivity of all techniques for Oryum and lancet were 100%. The false positivity of Oryum-VP, WP and lancet were found 0%. The Oryum-VP technique was found the best for intrapatient coefficient of variation (CV) (10.72%) (p < 0.001). The interpatient CV was similar in the Oryum-VP, VC, VCC and lancet techniques and was different from the Oryum-WP (p < 0.001). In the second section, all Oryum techniques yielded high sensitivities (100%). False-positive results were obtained more in Oryum-WC and WCC. Oryum-WP technique had the lowest pain score. In the 3rd section, the high positive correlation between histamine concentrations was observed (r = 0.731). In terms of time and allergen adequacy, Oryum-WP was superior to the lancet. CONCLUSION: Oryum-VP and WP techniques are reliable, tolerable and comparable with the lancet technique. |
format | Online Article Text |
id | pubmed-7218071 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | World Allergy Organization |
record_format | MEDLINE/PubMed |
spelling | pubmed-72180712020-05-15 Fine-tuning the use of a skin prick test device Kahveci, Melike Karabulut, Erdem Soyer, Ozge Sahiner, Umit Murat Buyuktiryaki, Betul Sekerel, Bulent Enis World Allergy Organ J Article BACKGROUND: Skin prick tests (SPTs) are the gold standard for the diagnosis of IgE-mediated allergic diseases. Newly introduced devices have different results in performance. This study aimed to provide data for sensitivity, reproducibility, and acceptability of a new SPT device by using different techniques. METHODS: The study was conducted in 4 sections. Different application techniques were evaluated. In the first section, a drop of histamine/saline was put by vial (V). In the second section, it was taken from a well via the test device (W). ALK® Lancet served as a reference in both sections. The techniques were as follows; 1) apply vertical pressure (VP/WP), 2) apply vertical pressure and rotate 90° clockwise (VC/WC), 3) apply vertical pressure and rotate 90° clockwise and then counter-clockwise (VCC/WCC). Pain assessment was performed by using the Wong-Baker FACES Pain Rating Scale. Different histamine concentrations were transferred from the well by the Oryum device and applied as WC in section 3. Lancet and Oryum-WP were compared in terms of time and allergen adequacy in section 4. RESULTS: In the first section the sensitivity of all techniques for Oryum and lancet were 100%. The false positivity of Oryum-VP, WP and lancet were found 0%. The Oryum-VP technique was found the best for intrapatient coefficient of variation (CV) (10.72%) (p < 0.001). The interpatient CV was similar in the Oryum-VP, VC, VCC and lancet techniques and was different from the Oryum-WP (p < 0.001). In the second section, all Oryum techniques yielded high sensitivities (100%). False-positive results were obtained more in Oryum-WC and WCC. Oryum-WP technique had the lowest pain score. In the 3rd section, the high positive correlation between histamine concentrations was observed (r = 0.731). In terms of time and allergen adequacy, Oryum-WP was superior to the lancet. CONCLUSION: Oryum-VP and WP techniques are reliable, tolerable and comparable with the lancet technique. World Allergy Organization 2020-05-08 /pmc/articles/PMC7218071/ /pubmed/32419899 http://dx.doi.org/10.1016/j.waojou.2020.100122 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kahveci, Melike Karabulut, Erdem Soyer, Ozge Sahiner, Umit Murat Buyuktiryaki, Betul Sekerel, Bulent Enis Fine-tuning the use of a skin prick test device |
title | Fine-tuning the use of a skin prick test device |
title_full | Fine-tuning the use of a skin prick test device |
title_fullStr | Fine-tuning the use of a skin prick test device |
title_full_unstemmed | Fine-tuning the use of a skin prick test device |
title_short | Fine-tuning the use of a skin prick test device |
title_sort | fine-tuning the use of a skin prick test device |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7218071/ https://www.ncbi.nlm.nih.gov/pubmed/32419899 http://dx.doi.org/10.1016/j.waojou.2020.100122 |
work_keys_str_mv | AT kahvecimelike finetuningtheuseofaskinpricktestdevice AT karabuluterdem finetuningtheuseofaskinpricktestdevice AT soyerozge finetuningtheuseofaskinpricktestdevice AT sahinerumitmurat finetuningtheuseofaskinpricktestdevice AT buyuktiryakibetul finetuningtheuseofaskinpricktestdevice AT sekerelbulentenis finetuningtheuseofaskinpricktestdevice |