Cargando…
Peripheral Blood Stem Cell Harvest HPC Count Is an Effective Surrogate Marker for CD34+ Cell Count in Allogeneic Stem Cell Transplant Setting
OBJECTIVE: We assessed the predictive potential of XN-HPC for CD34+ cell count as obtained through Sysmex automated hematology analyzers (XN-1000). METHODS: This study was conducted at the National Institute of Blood Diseases and Bone Marrow Transplantation in 84 donors between December 2012 and Dec...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Neoplasia Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7218209/ https://www.ncbi.nlm.nih.gov/pubmed/32408157 http://dx.doi.org/10.1016/j.tranon.2020.100788 |
_version_ | 1783532751527346176 |
---|---|
author | Jamal, Aisha Khan, Mohammad Tahir Parveen, Sadia Rizvi, Qurratulain Farzana, Tasneem Zaidi, Uzma Borhany, Munira Siddiqui, Saima Ansari, Saqib Hussain Shamsi, Tahir Sultan |
author_facet | Jamal, Aisha Khan, Mohammad Tahir Parveen, Sadia Rizvi, Qurratulain Farzana, Tasneem Zaidi, Uzma Borhany, Munira Siddiqui, Saima Ansari, Saqib Hussain Shamsi, Tahir Sultan |
author_sort | Jamal, Aisha |
collection | PubMed |
description | OBJECTIVE: We assessed the predictive potential of XN-HPC for CD34+ cell count as obtained through Sysmex automated hematology analyzers (XN-1000). METHODS: This study was conducted at the National Institute of Blood Diseases and Bone Marrow Transplantation in 84 donors between December 2012 and December 2017 in the first phase and later validated in 112 donors between December 2017 and December 2018. Sysmex XN-1000 and BD FACS Calibur estimated XN-HPC and CD34+ cells of peripheral blood apheresis product, respectively. Spearman's correlation was assessed between XN-HPC and CD34+ cell count followed by receiver operating characteristic curve calculation to determine the XN-HPC cutoff for a CD34+ count of ≥2 million cells/kg of recipient's body weight RESULTS: There is a moderately positive correlation (P value = .003) between XN-HPC and CD34+ count. Receiver operating characteristic curve analyses demonstrated that a cutoff value for XN-HPC of ≥1·845×10(6)cells/kg of recipient's body weight has a specificity and sensitivity of 100% and 78·2%, respectively, for predicting the CD34+ count of ≥2 million cells/kg of recipient's body weight. This cutoff value of XN-HPC was prospectively validated in 112 donors. The positive predictive value was found to be 100%, while negative predictive value was 17%. CONCLUSION: XN-HPC has a highly promising potential to serve as a cost-effective and time-saving surrogate for CD34+ cell count. |
format | Online Article Text |
id | pubmed-7218209 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Neoplasia Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-72182092020-05-15 Peripheral Blood Stem Cell Harvest HPC Count Is an Effective Surrogate Marker for CD34+ Cell Count in Allogeneic Stem Cell Transplant Setting Jamal, Aisha Khan, Mohammad Tahir Parveen, Sadia Rizvi, Qurratulain Farzana, Tasneem Zaidi, Uzma Borhany, Munira Siddiqui, Saima Ansari, Saqib Hussain Shamsi, Tahir Sultan Transl Oncol Original article OBJECTIVE: We assessed the predictive potential of XN-HPC for CD34+ cell count as obtained through Sysmex automated hematology analyzers (XN-1000). METHODS: This study was conducted at the National Institute of Blood Diseases and Bone Marrow Transplantation in 84 donors between December 2012 and December 2017 in the first phase and later validated in 112 donors between December 2017 and December 2018. Sysmex XN-1000 and BD FACS Calibur estimated XN-HPC and CD34+ cells of peripheral blood apheresis product, respectively. Spearman's correlation was assessed between XN-HPC and CD34+ cell count followed by receiver operating characteristic curve calculation to determine the XN-HPC cutoff for a CD34+ count of ≥2 million cells/kg of recipient's body weight RESULTS: There is a moderately positive correlation (P value = .003) between XN-HPC and CD34+ count. Receiver operating characteristic curve analyses demonstrated that a cutoff value for XN-HPC of ≥1·845×10(6)cells/kg of recipient's body weight has a specificity and sensitivity of 100% and 78·2%, respectively, for predicting the CD34+ count of ≥2 million cells/kg of recipient's body weight. This cutoff value of XN-HPC was prospectively validated in 112 donors. The positive predictive value was found to be 100%, while negative predictive value was 17%. CONCLUSION: XN-HPC has a highly promising potential to serve as a cost-effective and time-saving surrogate for CD34+ cell count. Neoplasia Press 2020-05-11 /pmc/articles/PMC7218209/ /pubmed/32408157 http://dx.doi.org/10.1016/j.tranon.2020.100788 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original article Jamal, Aisha Khan, Mohammad Tahir Parveen, Sadia Rizvi, Qurratulain Farzana, Tasneem Zaidi, Uzma Borhany, Munira Siddiqui, Saima Ansari, Saqib Hussain Shamsi, Tahir Sultan Peripheral Blood Stem Cell Harvest HPC Count Is an Effective Surrogate Marker for CD34+ Cell Count in Allogeneic Stem Cell Transplant Setting |
title | Peripheral Blood Stem Cell Harvest HPC Count Is an Effective Surrogate Marker for CD34+ Cell Count in Allogeneic Stem Cell Transplant Setting |
title_full | Peripheral Blood Stem Cell Harvest HPC Count Is an Effective Surrogate Marker for CD34+ Cell Count in Allogeneic Stem Cell Transplant Setting |
title_fullStr | Peripheral Blood Stem Cell Harvest HPC Count Is an Effective Surrogate Marker for CD34+ Cell Count in Allogeneic Stem Cell Transplant Setting |
title_full_unstemmed | Peripheral Blood Stem Cell Harvest HPC Count Is an Effective Surrogate Marker for CD34+ Cell Count in Allogeneic Stem Cell Transplant Setting |
title_short | Peripheral Blood Stem Cell Harvest HPC Count Is an Effective Surrogate Marker for CD34+ Cell Count in Allogeneic Stem Cell Transplant Setting |
title_sort | peripheral blood stem cell harvest hpc count is an effective surrogate marker for cd34+ cell count in allogeneic stem cell transplant setting |
topic | Original article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7218209/ https://www.ncbi.nlm.nih.gov/pubmed/32408157 http://dx.doi.org/10.1016/j.tranon.2020.100788 |
work_keys_str_mv | AT jamalaisha peripheralbloodstemcellharvesthpccountisaneffectivesurrogatemarkerforcd34cellcountinallogeneicstemcelltransplantsetting AT khanmohammadtahir peripheralbloodstemcellharvesthpccountisaneffectivesurrogatemarkerforcd34cellcountinallogeneicstemcelltransplantsetting AT parveensadia peripheralbloodstemcellharvesthpccountisaneffectivesurrogatemarkerforcd34cellcountinallogeneicstemcelltransplantsetting AT rizviqurratulain peripheralbloodstemcellharvesthpccountisaneffectivesurrogatemarkerforcd34cellcountinallogeneicstemcelltransplantsetting AT farzanatasneem peripheralbloodstemcellharvesthpccountisaneffectivesurrogatemarkerforcd34cellcountinallogeneicstemcelltransplantsetting AT zaidiuzma peripheralbloodstemcellharvesthpccountisaneffectivesurrogatemarkerforcd34cellcountinallogeneicstemcelltransplantsetting AT borhanymunira peripheralbloodstemcellharvesthpccountisaneffectivesurrogatemarkerforcd34cellcountinallogeneicstemcelltransplantsetting AT siddiquisaima peripheralbloodstemcellharvesthpccountisaneffectivesurrogatemarkerforcd34cellcountinallogeneicstemcelltransplantsetting AT ansarisaqibhussain peripheralbloodstemcellharvesthpccountisaneffectivesurrogatemarkerforcd34cellcountinallogeneicstemcelltransplantsetting AT shamsitahirsultan peripheralbloodstemcellharvesthpccountisaneffectivesurrogatemarkerforcd34cellcountinallogeneicstemcelltransplantsetting |