Wideband Self-Calibration Method of Inductive CTs and Verification of Determined Values of Current and Phase Errors at Harmonics for Transformation of Distorted Current

Self-calibration of a designed wideband inductive current transformer (CT) was carried out in the ampere-turns condition. This method does not require a reference transducer. The values of current and phase errors at the harmonics of frequencies from 100 Hz to 5 kHz were determined for the distorted...

Descripción completa

Detalles Bibliográficos
Autores principales: Stano, Ernest, Kaczmarek, Michal
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7218722/
https://www.ncbi.nlm.nih.gov/pubmed/32290417
http://dx.doi.org/10.3390/s20082167
_version_ 1783532853890383872
author Stano, Ernest
Kaczmarek, Michal
author_facet Stano, Ernest
Kaczmarek, Michal
author_sort Stano, Ernest
collection PubMed
description Self-calibration of a designed wideband inductive current transformer (CT) was carried out in the ampere-turns condition. This method does not require a reference transducer. The values of current and phase errors at the harmonics of frequencies from 100 Hz to 5 kHz were determined for the distorted primary current of the rated main frequency equal to 50 Hz. These results were verified based on the comparison of values measured between two CTs and calculated as the difference between values obtained from their calibration. Moreover, from vectorial diagrams drawn for transformation of the higher harmonics, the source of the change in the values of current and phase errors with frequency is explained. Furthermore, the method for calculation of the values of the corresponding harmonics of the current associated with the active power losses in the core and the magnetization current is presented.
format Online
Article
Text
id pubmed-7218722
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72187222020-05-22 Wideband Self-Calibration Method of Inductive CTs and Verification of Determined Values of Current and Phase Errors at Harmonics for Transformation of Distorted Current Stano, Ernest Kaczmarek, Michal Sensors (Basel) Article Self-calibration of a designed wideband inductive current transformer (CT) was carried out in the ampere-turns condition. This method does not require a reference transducer. The values of current and phase errors at the harmonics of frequencies from 100 Hz to 5 kHz were determined for the distorted primary current of the rated main frequency equal to 50 Hz. These results were verified based on the comparison of values measured between two CTs and calculated as the difference between values obtained from their calibration. Moreover, from vectorial diagrams drawn for transformation of the higher harmonics, the source of the change in the values of current and phase errors with frequency is explained. Furthermore, the method for calculation of the values of the corresponding harmonics of the current associated with the active power losses in the core and the magnetization current is presented. MDPI 2020-04-11 /pmc/articles/PMC7218722/ /pubmed/32290417 http://dx.doi.org/10.3390/s20082167 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Stano, Ernest
Kaczmarek, Michal
Wideband Self-Calibration Method of Inductive CTs and Verification of Determined Values of Current and Phase Errors at Harmonics for Transformation of Distorted Current
title Wideband Self-Calibration Method of Inductive CTs and Verification of Determined Values of Current and Phase Errors at Harmonics for Transformation of Distorted Current
title_full Wideband Self-Calibration Method of Inductive CTs and Verification of Determined Values of Current and Phase Errors at Harmonics for Transformation of Distorted Current
title_fullStr Wideband Self-Calibration Method of Inductive CTs and Verification of Determined Values of Current and Phase Errors at Harmonics for Transformation of Distorted Current
title_full_unstemmed Wideband Self-Calibration Method of Inductive CTs and Verification of Determined Values of Current and Phase Errors at Harmonics for Transformation of Distorted Current
title_short Wideband Self-Calibration Method of Inductive CTs and Verification of Determined Values of Current and Phase Errors at Harmonics for Transformation of Distorted Current
title_sort wideband self-calibration method of inductive cts and verification of determined values of current and phase errors at harmonics for transformation of distorted current
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7218722/
https://www.ncbi.nlm.nih.gov/pubmed/32290417
http://dx.doi.org/10.3390/s20082167
work_keys_str_mv AT stanoernest widebandselfcalibrationmethodofinductivectsandverificationofdeterminedvaluesofcurrentandphaseerrorsatharmonicsfortransformationofdistortedcurrent
AT kaczmarekmichal widebandselfcalibrationmethodofinductivectsandverificationofdeterminedvaluesofcurrentandphaseerrorsatharmonicsfortransformationofdistortedcurrent