Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case
This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL con...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219000/ https://www.ncbi.nlm.nih.gov/pubmed/32454886 http://dx.doi.org/10.1155/2020/9163085 |
_version_ | 1783532908122734592 |
---|---|
author | Basri, Adi A. Zuber, Mohammad Basri, Ernnie I. Zakaria, Muhammad S. Aziz, Ahmad F. A. Tamagawa, Masaaki Ahmad, Kamarul A. |
author_facet | Basri, Adi A. Zuber, Mohammad Basri, Ernnie I. Zakaria, Muhammad S. Aziz, Ahmad F. A. Tamagawa, Masaaki Ahmad, Kamarul A. |
author_sort | Basri, Adi A. |
collection | PubMed |
description | This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient's aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA. |
format | Online Article Text |
id | pubmed-7219000 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-72190002020-05-23 Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case Basri, Adi A. Zuber, Mohammad Basri, Ernnie I. Zakaria, Muhammad S. Aziz, Ahmad F. A. Tamagawa, Masaaki Ahmad, Kamarul A. Comput Math Methods Med Research Article This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient's aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA. Hindawi 2020-05-04 /pmc/articles/PMC7219000/ /pubmed/32454886 http://dx.doi.org/10.1155/2020/9163085 Text en Copyright © 2020 Adi A. Basri et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Basri, Adi A. Zuber, Mohammad Basri, Ernnie I. Zakaria, Muhammad S. Aziz, Ahmad F. A. Tamagawa, Masaaki Ahmad, Kamarul A. Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case |
title | Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case |
title_full | Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case |
title_fullStr | Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case |
title_full_unstemmed | Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case |
title_short | Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case |
title_sort | fluid structure interaction on paravalvular leakage of transcatheter aortic valve implantation related to aortic stenosis: a patient-specific case |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219000/ https://www.ncbi.nlm.nih.gov/pubmed/32454886 http://dx.doi.org/10.1155/2020/9163085 |
work_keys_str_mv | AT basriadia fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase AT zubermohammad fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase AT basriernniei fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase AT zakariamuhammads fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase AT azizahmadfa fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase AT tamagawamasaaki fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase AT ahmadkamarula fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase |