Cargando…

Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case

This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL con...

Descripción completa

Detalles Bibliográficos
Autores principales: Basri, Adi A., Zuber, Mohammad, Basri, Ernnie I., Zakaria, Muhammad S., Aziz, Ahmad F. A., Tamagawa, Masaaki, Ahmad, Kamarul A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219000/
https://www.ncbi.nlm.nih.gov/pubmed/32454886
http://dx.doi.org/10.1155/2020/9163085
_version_ 1783532908122734592
author Basri, Adi A.
Zuber, Mohammad
Basri, Ernnie I.
Zakaria, Muhammad S.
Aziz, Ahmad F. A.
Tamagawa, Masaaki
Ahmad, Kamarul A.
author_facet Basri, Adi A.
Zuber, Mohammad
Basri, Ernnie I.
Zakaria, Muhammad S.
Aziz, Ahmad F. A.
Tamagawa, Masaaki
Ahmad, Kamarul A.
author_sort Basri, Adi A.
collection PubMed
description This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient's aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA.
format Online
Article
Text
id pubmed-7219000
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-72190002020-05-23 Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case Basri, Adi A. Zuber, Mohammad Basri, Ernnie I. Zakaria, Muhammad S. Aziz, Ahmad F. A. Tamagawa, Masaaki Ahmad, Kamarul A. Comput Math Methods Med Research Article This study investigated the impact of paravalvular leakage (PVL) in relation to the different valve openings of the transcatheter aortic valve implantation (TAVI) valve using the fluid structure interaction (FSI) approach. Limited studies were found on the subject of FSI with regards to TAVI-PVL condition, which involves both fluid and structural responses in coupling interaction. Hence, further FSI simulation with the two-way coupling method is implemented to investigate the effects of hemodynamics blood flow along the patient-specific aorta model subjected to the interrelationship between PVL and the different valve openings using the established FSI software ANSYS 16.1. A 3D patient-specific aorta model is constructed using MIMICS software. The TAVI valve identical to Edward SAPIEN XT 26 (Edwards Lifesciences, Irvine, California), at different Geometrical Orifice Areas (GOAs), is implanted into the patient's aortic annulus. The leaflet opening of the TAVI valve is drawn according to severity of GOA opening represented in terms of 100%, 80%, 60%, and 40% opening, respectively. The result proved that the smallest percentage of GOA opening produced the highest possibility of PVL, increased the recirculatory flow proximally to the inner wall of the ascending aorta, and produced lower backflow velocity streamlines through the side area of PVL region. Overall, 40% GOA produced 89.17% increment of maximum velocity magnitude, 19.97% of pressure drop, 65.70% of maximum WSS magnitude, and a decrement of 33.62% total displacement magnitude with respect to the 100% GOA. Hindawi 2020-05-04 /pmc/articles/PMC7219000/ /pubmed/32454886 http://dx.doi.org/10.1155/2020/9163085 Text en Copyright © 2020 Adi A. Basri et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Basri, Adi A.
Zuber, Mohammad
Basri, Ernnie I.
Zakaria, Muhammad S.
Aziz, Ahmad F. A.
Tamagawa, Masaaki
Ahmad, Kamarul A.
Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case
title Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case
title_full Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case
title_fullStr Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case
title_full_unstemmed Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case
title_short Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case
title_sort fluid structure interaction on paravalvular leakage of transcatheter aortic valve implantation related to aortic stenosis: a patient-specific case
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219000/
https://www.ncbi.nlm.nih.gov/pubmed/32454886
http://dx.doi.org/10.1155/2020/9163085
work_keys_str_mv AT basriadia fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase
AT zubermohammad fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase
AT basriernniei fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase
AT zakariamuhammads fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase
AT azizahmadfa fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase
AT tamagawamasaaki fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase
AT ahmadkamarula fluidstructureinteractiononparavalvularleakageoftranscatheteraorticvalveimplantationrelatedtoaorticstenosisapatientspecificcase