Cargando…

FEASIBILITY AND RELIABILITY OF MUSCULOSKELETAL ULTRASOUND MEASUREMENT OF THE MEDIAL PATELLOFEMORAL LIGAMENT

BACKGROUND: The medial patellofemoral ligament (MPFL) is an important soft tissue constraint to preventing patellar dislocations in young athletes. The anatomy of the MPFL has been investigated in cadaveric studies and magnetic resonance studies. No studies to date have provided anatomical data of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Stracciolini, Andrea, Boucher, Laura, Jackson, Sarah, Brown, Naomi, Magrini, Danielle, McKee-Proctor, Maxwell, d’Hemecourt, Pierre, Delzell, Patricia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219007/
http://dx.doi.org/10.1177/2325967120S00185
_version_ 1783532909545652224
author Stracciolini, Andrea
Boucher, Laura
Jackson, Sarah
Brown, Naomi
Magrini, Danielle
McKee-Proctor, Maxwell
d’Hemecourt, Pierre
Delzell, Patricia
author_facet Stracciolini, Andrea
Boucher, Laura
Jackson, Sarah
Brown, Naomi
Magrini, Danielle
McKee-Proctor, Maxwell
d’Hemecourt, Pierre
Delzell, Patricia
author_sort Stracciolini, Andrea
collection PubMed
description BACKGROUND: The medial patellofemoral ligament (MPFL) is an important soft tissue constraint to preventing patellar dislocations in young athletes. The anatomy of the MPFL has been investigated in cadaveric studies and magnetic resonance studies. No studies to date have provided anatomical data of the MPFL on ultrasonography. PURPOSE: To investigate the feasibility of musculoskeletal ultrasonography for the evaluation of the MPFL, and to determine interrater and intrarater reliability for MPFL ultrasound measures. METHODS: Ten control participants (20 knees) 20 to 50 years underwent ultrasonography performed by 3 researchers (musculoskeletal ultrasound radiologist, athletic trainer/biomechanist, primary care sports medicine physician) from 3 different institutions for interrater reliability testing. Intrarater reliability testing was performed at 2 separate institutions by 4 physicians, each performing the same knee ultrasound protocol on 20 knees in 10 study participants 2 to 3 weeks apart. In total, 180 images were created for interrater reliability, and 480 images for intrarater reliability. Examinations were performed with linear high-frequency transducers (10-18 MHz) with the participant in the supine position and the extremity flexed at 45°. Measurements included ligament length (long axis to ligament) from the patellar to the femoral attachment sites, ligament width (short axis to ligament) at the patellar attachment, and ligament thickness (long axis to ligament) midway between the patella and femur. Mean and SD were calculated for all measurements. Intraclass correlation coefficient (ICC) analysis was used to assess intrarater and interrater reliability. ICC values < 0.40 indicated poor reliability, whereas those between 0.40 and 0.75 indicated fair to good reliability, and those > 0.75 indicated excellent reliability. RESULTS: The mean US value for MPFL length was 44.83mm (SD 6.68), mean thickness 2.66mm (SD 0.85), and mean width 11.76mm (SD 2.99). The overall ICC values for interrater reliability testing indicated fair to good reliability for length measures (0.7) and poor reliability for thickness (–0.1) and width (0.3; Table 1.1). Overall ICC values for intrarater reliability indicated fair to good reliability for length (0.5), excellent for thickness (0.9), and poor reliability for width (–0.3; Table 1.2). CONCLUSIONS: Musculoskeletal ultrasonography is a feasible and reliable office-based method of measuring MPFL length and thickness. These quantitative measures set the groundwork for establishing normative anatomical measures of the MPFL in athletes and establish a protocol for testing and measuring the MPFL using musculoskeletal ultrasonography.
format Online
Article
Text
id pubmed-7219007
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-72190072020-05-18 FEASIBILITY AND RELIABILITY OF MUSCULOSKELETAL ULTRASOUND MEASUREMENT OF THE MEDIAL PATELLOFEMORAL LIGAMENT Stracciolini, Andrea Boucher, Laura Jackson, Sarah Brown, Naomi Magrini, Danielle McKee-Proctor, Maxwell d’Hemecourt, Pierre Delzell, Patricia Orthop J Sports Med Article BACKGROUND: The medial patellofemoral ligament (MPFL) is an important soft tissue constraint to preventing patellar dislocations in young athletes. The anatomy of the MPFL has been investigated in cadaveric studies and magnetic resonance studies. No studies to date have provided anatomical data of the MPFL on ultrasonography. PURPOSE: To investigate the feasibility of musculoskeletal ultrasonography for the evaluation of the MPFL, and to determine interrater and intrarater reliability for MPFL ultrasound measures. METHODS: Ten control participants (20 knees) 20 to 50 years underwent ultrasonography performed by 3 researchers (musculoskeletal ultrasound radiologist, athletic trainer/biomechanist, primary care sports medicine physician) from 3 different institutions for interrater reliability testing. Intrarater reliability testing was performed at 2 separate institutions by 4 physicians, each performing the same knee ultrasound protocol on 20 knees in 10 study participants 2 to 3 weeks apart. In total, 180 images were created for interrater reliability, and 480 images for intrarater reliability. Examinations were performed with linear high-frequency transducers (10-18 MHz) with the participant in the supine position and the extremity flexed at 45°. Measurements included ligament length (long axis to ligament) from the patellar to the femoral attachment sites, ligament width (short axis to ligament) at the patellar attachment, and ligament thickness (long axis to ligament) midway between the patella and femur. Mean and SD were calculated for all measurements. Intraclass correlation coefficient (ICC) analysis was used to assess intrarater and interrater reliability. ICC values < 0.40 indicated poor reliability, whereas those between 0.40 and 0.75 indicated fair to good reliability, and those > 0.75 indicated excellent reliability. RESULTS: The mean US value for MPFL length was 44.83mm (SD 6.68), mean thickness 2.66mm (SD 0.85), and mean width 11.76mm (SD 2.99). The overall ICC values for interrater reliability testing indicated fair to good reliability for length measures (0.7) and poor reliability for thickness (–0.1) and width (0.3; Table 1.1). Overall ICC values for intrarater reliability indicated fair to good reliability for length (0.5), excellent for thickness (0.9), and poor reliability for width (–0.3; Table 1.2). CONCLUSIONS: Musculoskeletal ultrasonography is a feasible and reliable office-based method of measuring MPFL length and thickness. These quantitative measures set the groundwork for establishing normative anatomical measures of the MPFL in athletes and establish a protocol for testing and measuring the MPFL using musculoskeletal ultrasonography. SAGE Publications 2020-04-30 /pmc/articles/PMC7219007/ http://dx.doi.org/10.1177/2325967120S00185 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc-nd/4.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For article reuse guidelines, please visit SAGE’s website at http://www.sagepub.com/journals-permissions.
spellingShingle Article
Stracciolini, Andrea
Boucher, Laura
Jackson, Sarah
Brown, Naomi
Magrini, Danielle
McKee-Proctor, Maxwell
d’Hemecourt, Pierre
Delzell, Patricia
FEASIBILITY AND RELIABILITY OF MUSCULOSKELETAL ULTRASOUND MEASUREMENT OF THE MEDIAL PATELLOFEMORAL LIGAMENT
title FEASIBILITY AND RELIABILITY OF MUSCULOSKELETAL ULTRASOUND MEASUREMENT OF THE MEDIAL PATELLOFEMORAL LIGAMENT
title_full FEASIBILITY AND RELIABILITY OF MUSCULOSKELETAL ULTRASOUND MEASUREMENT OF THE MEDIAL PATELLOFEMORAL LIGAMENT
title_fullStr FEASIBILITY AND RELIABILITY OF MUSCULOSKELETAL ULTRASOUND MEASUREMENT OF THE MEDIAL PATELLOFEMORAL LIGAMENT
title_full_unstemmed FEASIBILITY AND RELIABILITY OF MUSCULOSKELETAL ULTRASOUND MEASUREMENT OF THE MEDIAL PATELLOFEMORAL LIGAMENT
title_short FEASIBILITY AND RELIABILITY OF MUSCULOSKELETAL ULTRASOUND MEASUREMENT OF THE MEDIAL PATELLOFEMORAL LIGAMENT
title_sort feasibility and reliability of musculoskeletal ultrasound measurement of the medial patellofemoral ligament
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219007/
http://dx.doi.org/10.1177/2325967120S00185
work_keys_str_mv AT straccioliniandrea feasibilityandreliabilityofmusculoskeletalultrasoundmeasurementofthemedialpatellofemoralligament
AT boucherlaura feasibilityandreliabilityofmusculoskeletalultrasoundmeasurementofthemedialpatellofemoralligament
AT jacksonsarah feasibilityandreliabilityofmusculoskeletalultrasoundmeasurementofthemedialpatellofemoralligament
AT brownnaomi feasibilityandreliabilityofmusculoskeletalultrasoundmeasurementofthemedialpatellofemoralligament
AT magrinidanielle feasibilityandreliabilityofmusculoskeletalultrasoundmeasurementofthemedialpatellofemoralligament
AT mckeeproctormaxwell feasibilityandreliabilityofmusculoskeletalultrasoundmeasurementofthemedialpatellofemoralligament
AT dhemecourtpierre feasibilityandreliabilityofmusculoskeletalultrasoundmeasurementofthemedialpatellofemoralligament
AT delzellpatricia feasibilityandreliabilityofmusculoskeletalultrasoundmeasurementofthemedialpatellofemoralligament