Cargando…

Femoral Tunnel Placement Analysis in ACL Reconstruction Through Use of a Novel 3-Dimensional Reference With Biplanar Stereoradiographic Imaging

BACKGROUND: The femoral-sided anatomic footprint of the anterior cruciate ligament (ACL) has been widely studied during the past decades. Nonanatomic placement is an important cause of ACL reconstruction (ACLR) failure. PURPOSE: To describe femoral tunnel placement in ACLR through use of a comprehen...

Descripción completa

Detalles Bibliográficos
Autores principales: Montreuil, Julien, Saleh, Joseph, Cresson, Thierry, De Guise, Jacques A., Lavoie, Frédéric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219010/
https://www.ncbi.nlm.nih.gov/pubmed/32426408
http://dx.doi.org/10.1177/2325967120915709
_version_ 1783532910255538176
author Montreuil, Julien
Saleh, Joseph
Cresson, Thierry
De Guise, Jacques A.
Lavoie, Frédéric
author_facet Montreuil, Julien
Saleh, Joseph
Cresson, Thierry
De Guise, Jacques A.
Lavoie, Frédéric
author_sort Montreuil, Julien
collection PubMed
description BACKGROUND: The femoral-sided anatomic footprint of the anterior cruciate ligament (ACL) has been widely studied during the past decades. Nonanatomic placement is an important cause of ACL reconstruction (ACLR) failure. PURPOSE: To describe femoral tunnel placement in ACLR through use of a comprehensive 3-dimensional (3D) cylindrical coordinate system combining both the traditional clockface technique and the quadrant method. Our objective was to validate this technique and evaluate its reproducibility. STUDY DESIGN: Descriptive laboratory study. METHODS: The EOS Imaging System was used to make 3D models of the knee for 37 patients who had undergone ACLR. We designed an automated cylindrical reference software program individualized to the distal femoral morphology of each patient. Cylinder parameters were collected from 2 observers’ series of 3D models. Each independent observer also manually measured the corresponding parameters using a lateral view of the 3D contours and a 2-dimensional stereoradiographic image for the corresponding patient. RESULTS: The average cylinder produced from the first observer’s EOS 3D models had a 30.0° orientation (95% CI, 28.4°-31.5°), 40.4 mm length (95% CI, 39.3-41.4 mm), and 19.3 mm diameter (95% CI, 18.6-20.0 mm). For the second observer, these measurements were 29.7° (95% CI, 28.1°-31.3°), 40.7 mm (95% CI, 39.7-41.8 mm), and 19.7 mm (95% CI, 18.8-20.6 mm), respectively. Our method showed moderate intertest intraclass correlation among all 3 measuring techniques for both length (r = 0.68) and diameter (r = 0.63) but poor correlation for orientation (r = 0.44). In terms of interobserver reproducibility of the automated EOS 3D method, similar results were obtained: moderate to excellent correlations for length (r = 0.95; P < .001) and diameter (r = 0.66; P < .001) but poor correlation for orientation (r = 0.29; P < .08). With this reference system, we were able to describe the placement of each individual femoral tunnel aperture, averaging a difference of less than 10 mm from the historical anatomic description by Bernard et al. CONCLUSION: This novel 3D cylindrical coordinate system using biplanar, stereoradiographic, low-irradiation imaging showed a precision comparable with standard manual measurements for ACLR femoral tunnel placement. Our results also suggest that automated cylinders issued from EOS 3D models show adequate accuracy and reproducibility. CLINICAL RELEVANCE: This technique will open multiple possibilities in ACLR femoral tunnel placement in terms of preoperative planning, postoperative feedback, and even intraoperative guidance with augmented reality.
format Online
Article
Text
id pubmed-7219010
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-72190102020-05-18 Femoral Tunnel Placement Analysis in ACL Reconstruction Through Use of a Novel 3-Dimensional Reference With Biplanar Stereoradiographic Imaging Montreuil, Julien Saleh, Joseph Cresson, Thierry De Guise, Jacques A. Lavoie, Frédéric Orthop J Sports Med Article BACKGROUND: The femoral-sided anatomic footprint of the anterior cruciate ligament (ACL) has been widely studied during the past decades. Nonanatomic placement is an important cause of ACL reconstruction (ACLR) failure. PURPOSE: To describe femoral tunnel placement in ACLR through use of a comprehensive 3-dimensional (3D) cylindrical coordinate system combining both the traditional clockface technique and the quadrant method. Our objective was to validate this technique and evaluate its reproducibility. STUDY DESIGN: Descriptive laboratory study. METHODS: The EOS Imaging System was used to make 3D models of the knee for 37 patients who had undergone ACLR. We designed an automated cylindrical reference software program individualized to the distal femoral morphology of each patient. Cylinder parameters were collected from 2 observers’ series of 3D models. Each independent observer also manually measured the corresponding parameters using a lateral view of the 3D contours and a 2-dimensional stereoradiographic image for the corresponding patient. RESULTS: The average cylinder produced from the first observer’s EOS 3D models had a 30.0° orientation (95% CI, 28.4°-31.5°), 40.4 mm length (95% CI, 39.3-41.4 mm), and 19.3 mm diameter (95% CI, 18.6-20.0 mm). For the second observer, these measurements were 29.7° (95% CI, 28.1°-31.3°), 40.7 mm (95% CI, 39.7-41.8 mm), and 19.7 mm (95% CI, 18.8-20.6 mm), respectively. Our method showed moderate intertest intraclass correlation among all 3 measuring techniques for both length (r = 0.68) and diameter (r = 0.63) but poor correlation for orientation (r = 0.44). In terms of interobserver reproducibility of the automated EOS 3D method, similar results were obtained: moderate to excellent correlations for length (r = 0.95; P < .001) and diameter (r = 0.66; P < .001) but poor correlation for orientation (r = 0.29; P < .08). With this reference system, we were able to describe the placement of each individual femoral tunnel aperture, averaging a difference of less than 10 mm from the historical anatomic description by Bernard et al. CONCLUSION: This novel 3D cylindrical coordinate system using biplanar, stereoradiographic, low-irradiation imaging showed a precision comparable with standard manual measurements for ACLR femoral tunnel placement. Our results also suggest that automated cylinders issued from EOS 3D models show adequate accuracy and reproducibility. CLINICAL RELEVANCE: This technique will open multiple possibilities in ACLR femoral tunnel placement in terms of preoperative planning, postoperative feedback, and even intraoperative guidance with augmented reality. SAGE Publications 2020-04-29 /pmc/articles/PMC7219010/ /pubmed/32426408 http://dx.doi.org/10.1177/2325967120915709 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc-nd/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Montreuil, Julien
Saleh, Joseph
Cresson, Thierry
De Guise, Jacques A.
Lavoie, Frédéric
Femoral Tunnel Placement Analysis in ACL Reconstruction Through Use of a Novel 3-Dimensional Reference With Biplanar Stereoradiographic Imaging
title Femoral Tunnel Placement Analysis in ACL Reconstruction Through Use of a Novel 3-Dimensional Reference With Biplanar Stereoradiographic Imaging
title_full Femoral Tunnel Placement Analysis in ACL Reconstruction Through Use of a Novel 3-Dimensional Reference With Biplanar Stereoradiographic Imaging
title_fullStr Femoral Tunnel Placement Analysis in ACL Reconstruction Through Use of a Novel 3-Dimensional Reference With Biplanar Stereoradiographic Imaging
title_full_unstemmed Femoral Tunnel Placement Analysis in ACL Reconstruction Through Use of a Novel 3-Dimensional Reference With Biplanar Stereoradiographic Imaging
title_short Femoral Tunnel Placement Analysis in ACL Reconstruction Through Use of a Novel 3-Dimensional Reference With Biplanar Stereoradiographic Imaging
title_sort femoral tunnel placement analysis in acl reconstruction through use of a novel 3-dimensional reference with biplanar stereoradiographic imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219010/
https://www.ncbi.nlm.nih.gov/pubmed/32426408
http://dx.doi.org/10.1177/2325967120915709
work_keys_str_mv AT montreuiljulien femoraltunnelplacementanalysisinaclreconstructionthroughuseofanovel3dimensionalreferencewithbiplanarstereoradiographicimaging
AT salehjoseph femoraltunnelplacementanalysisinaclreconstructionthroughuseofanovel3dimensionalreferencewithbiplanarstereoradiographicimaging
AT cressonthierry femoraltunnelplacementanalysisinaclreconstructionthroughuseofanovel3dimensionalreferencewithbiplanarstereoradiographicimaging
AT deguisejacquesa femoraltunnelplacementanalysisinaclreconstructionthroughuseofanovel3dimensionalreferencewithbiplanarstereoradiographicimaging
AT lavoiefrederic femoraltunnelplacementanalysisinaclreconstructionthroughuseofanovel3dimensionalreferencewithbiplanarstereoradiographicimaging