Cargando…
A Smart Rig for Calibration of Gas Sensor Nodes
Electrochemical gas sensors require regular maintenance to check and secure proper functioning. Standard procedures usually involve testing and recalibration of the sensors, for which working environments are needed. Periodic calibration is therefore necessary to ensure reliable and accurate measure...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219255/ https://www.ncbi.nlm.nih.gov/pubmed/32326014 http://dx.doi.org/10.3390/s20082341 |
_version_ | 1783532962083504128 |
---|---|
author | Benammar, Mohieddine A. Ahmad, Sabbir H. M. Abdaoui, Abderrazak Tariq, Hasan Touati, Farid Al-Hitmi, Mohammed Crescini, Damiano |
author_facet | Benammar, Mohieddine A. Ahmad, Sabbir H. M. Abdaoui, Abderrazak Tariq, Hasan Touati, Farid Al-Hitmi, Mohammed Crescini, Damiano |
author_sort | Benammar, Mohieddine A. |
collection | PubMed |
description | Electrochemical gas sensors require regular maintenance to check and secure proper functioning. Standard procedures usually involve testing and recalibration of the sensors, for which working environments are needed. Periodic calibration is therefore necessary to ensure reliable and accurate measurements. This paper proposes a dedicated smart calibration rig with a set of novel features enabling simultaneous calibration of multiple sensors. The proposed calibration rig system comprises a gas mixing system, temperature control system, a test chamber, and a process-control PC that controls all calibration phases. The calibration process is automated by a LabVIEW-based platform that controls the calibration environment for the sensor nodes, logs sensor data, and best fit equation based on interpolation for every sensor on the node and uploads it to the sensor node for next deployments. The communication between the PC and the sensor nodes is performed using the same IEEE 802.15.4 (ZigBee) protocol that the nodes also use in field deployment for air quality measurement. The results presented demonstrate the effectiveness of the sensors calibration rig. |
format | Online Article Text |
id | pubmed-7219255 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-72192552020-05-22 A Smart Rig for Calibration of Gas Sensor Nodes Benammar, Mohieddine A. Ahmad, Sabbir H. M. Abdaoui, Abderrazak Tariq, Hasan Touati, Farid Al-Hitmi, Mohammed Crescini, Damiano Sensors (Basel) Article Electrochemical gas sensors require regular maintenance to check and secure proper functioning. Standard procedures usually involve testing and recalibration of the sensors, for which working environments are needed. Periodic calibration is therefore necessary to ensure reliable and accurate measurements. This paper proposes a dedicated smart calibration rig with a set of novel features enabling simultaneous calibration of multiple sensors. The proposed calibration rig system comprises a gas mixing system, temperature control system, a test chamber, and a process-control PC that controls all calibration phases. The calibration process is automated by a LabVIEW-based platform that controls the calibration environment for the sensor nodes, logs sensor data, and best fit equation based on interpolation for every sensor on the node and uploads it to the sensor node for next deployments. The communication between the PC and the sensor nodes is performed using the same IEEE 802.15.4 (ZigBee) protocol that the nodes also use in field deployment for air quality measurement. The results presented demonstrate the effectiveness of the sensors calibration rig. MDPI 2020-04-20 /pmc/articles/PMC7219255/ /pubmed/32326014 http://dx.doi.org/10.3390/s20082341 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Benammar, Mohieddine A. Ahmad, Sabbir H. M. Abdaoui, Abderrazak Tariq, Hasan Touati, Farid Al-Hitmi, Mohammed Crescini, Damiano A Smart Rig for Calibration of Gas Sensor Nodes |
title | A Smart Rig for Calibration of Gas Sensor Nodes |
title_full | A Smart Rig for Calibration of Gas Sensor Nodes |
title_fullStr | A Smart Rig for Calibration of Gas Sensor Nodes |
title_full_unstemmed | A Smart Rig for Calibration of Gas Sensor Nodes |
title_short | A Smart Rig for Calibration of Gas Sensor Nodes |
title_sort | smart rig for calibration of gas sensor nodes |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219255/ https://www.ncbi.nlm.nih.gov/pubmed/32326014 http://dx.doi.org/10.3390/s20082341 |
work_keys_str_mv | AT benammarmohieddinea asmartrigforcalibrationofgassensornodes AT ahmadsabbirhm asmartrigforcalibrationofgassensornodes AT abdaouiabderrazak asmartrigforcalibrationofgassensornodes AT tariqhasan asmartrigforcalibrationofgassensornodes AT touatifarid asmartrigforcalibrationofgassensornodes AT alhitmimohammed asmartrigforcalibrationofgassensornodes AT crescinidamiano asmartrigforcalibrationofgassensornodes AT benammarmohieddinea smartrigforcalibrationofgassensornodes AT ahmadsabbirhm smartrigforcalibrationofgassensornodes AT abdaouiabderrazak smartrigforcalibrationofgassensornodes AT tariqhasan smartrigforcalibrationofgassensornodes AT touatifarid smartrigforcalibrationofgassensornodes AT alhitmimohammed smartrigforcalibrationofgassensornodes AT crescinidamiano smartrigforcalibrationofgassensornodes |