Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Pharmacokinetic Evaluation of 7β-(3-Ethyl-cis-crotonoyloxy)-1α-(2-methylbutyryloxy)-3,14-dehydro-Z-notonipetranon in Rats

Recently, potent neuroprotective and anti-diabetic effects of 7β-(3-Ethyl-cis-crotonoyloxy)-1α-(2-methylbutyryloxy)-3,14-dehydro-Z-notonipetranone (ECN), a sesquiterpenoid isolated from Tussilago farfara Linnaeus, have been elucidated. To facilitate further pre-clinical evaluation in rats, an analyt...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Nae-Won, Lee, Jae-Young, Song, Kwangho, Kim, Min-Hwan, Yoon, Soyeon, Nguyen, Duy-Thuc, Kim, Sungho, Kim, Yeong Shik, Kim, Dae-Duk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7221868/
https://www.ncbi.nlm.nih.gov/pubmed/32294941
http://dx.doi.org/10.3390/molecules25081774
Descripción
Sumario:Recently, potent neuroprotective and anti-diabetic effects of 7β-(3-Ethyl-cis-crotonoyloxy)-1α-(2-methylbutyryloxy)-3,14-dehydro-Z-notonipetranone (ECN), a sesquiterpenoid isolated from Tussilago farfara Linnaeus, have been elucidated. To facilitate further pre-clinical evaluation in rats, an analytical method for the determination of ECN in rat plasma was developed and optimized by using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Plasma samples were pretreated by the protein precipitation method with an acetonitrile solution of losartan (LST) as the internal standard. Chromatographic separation was performed using a an Octadecyl-silica (ODS) column (2.6 µm, 100 x 4.6 mm) in the isocratic mode. The mobile phase, comprising 10 mM ammonium formate in water pH 5.75) and acetonitrile (11:89, v/v), was eluted at a flow rate of 0.4 mL/min. Mass spectrometric detection was performed in the multiple reaction monitoring mode with positive electrospray ionization, and the mass transitions of ECN and LST were m/z 431.3 to 97.3 and m/z 423.1 to 207.2, respectively. The calibration curves of spiked plasma samples were linear in the 10.0–10,000 ng/mL range (r(2) > 0.996). The lower limit of quantification (LLOQ) was determined as 10.0 ng/mL. Validation was conducted in the LLOQ, and three quality control (QC) sample levels (10.0, 25.0, 3750, and 7500 ng/mL) were studied. Among them, the relative standard deviation for the within- and between-run precisions was under 9.90%, and the relative error of the accuracies was within the −8.13% to 0.42% range. The validated method was successfully employed to investigate the pharmacokinetic properties of ECN in rats, which revealed the linear pharmacokinetic behavior of ECN for the first time.