Cargando…

Choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study

General anaesthesia is sometimes favoured over regional anaesthesia in ophthalmic surgery. The use of supraglottic airway (SGA) or laryngeal mask airway (LMA) as the primary airway device is increasing due to numerous advantages over tracheal intubation. Compared with 1st generation SGAs, 2nd genera...

Descripción completa

Detalles Bibliográficos
Autores principales: Seet, Edwin, Zhang, Jinbin, Macachor, Joselo, Kumar, Chandra M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7223643/
https://www.ncbi.nlm.nih.gov/pubmed/32274646
http://dx.doi.org/10.1007/s10877-020-00507-w
_version_ 1783533775637970944
author Seet, Edwin
Zhang, Jinbin
Macachor, Joselo
Kumar, Chandra M.
author_facet Seet, Edwin
Zhang, Jinbin
Macachor, Joselo
Kumar, Chandra M.
author_sort Seet, Edwin
collection PubMed
description General anaesthesia is sometimes favoured over regional anaesthesia in ophthalmic surgery. The use of supraglottic airway (SGA) or laryngeal mask airway (LMA) as the primary airway device is increasing due to numerous advantages over tracheal intubation. Compared with 1st generation SGAs, 2nd generation SGAs have an added benefit of isolating the airway from the alimentary tract. However, the vertical profile of SGAs may encroach into the surgical field and hence interfere with surgery. We investigated the vertical projections of 1st generation SGAs (LMA Classic, Ambu AuraFlex) and commonly used 2nd generation SGAs in our institution (LMA ProSeal, LMA Supreme, LMA Protector, Ambu AuraGain and I-gel) in a manikin model. Each device was connected to a corrugated catheter mount or angled connector following insertion as per usual clinical practice in our institutions. Vertical projections of all devices were measured from the chin using a centimetre ruler. Securing of airway device to the chin with an adhesive tape was possible for the LMA Classic and Ambu AuraFlex with straight corrugated connector, whereas the stiffer 2nd generations SGAs required the addition of an angled connector or straight corrugated tubing to direct the airway tube caudally, away from the surgical field. The LMA ProSeal had the lowest vertical projection amongst the 2nd generation SGAs and may be the suitable choice for ophthalmic surgery. We also describe a novel technique of utilising a 1st generation SGA with placement of an orogastric tube, although with some reservations. This study has several limitations and transferability of our findings into clinical practice is questionable as the use of a manikin may not fully imitate the real condition of the patient. Our study is the first study comparing vertical projected height of different SGAs in manikin, but future studies should investigate the use of SGA in the clinical setting during ophthalmic surgery.
format Online
Article
Text
id pubmed-7223643
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-72236432020-05-15 Choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study Seet, Edwin Zhang, Jinbin Macachor, Joselo Kumar, Chandra M. J Clin Monit Comput Original Research General anaesthesia is sometimes favoured over regional anaesthesia in ophthalmic surgery. The use of supraglottic airway (SGA) or laryngeal mask airway (LMA) as the primary airway device is increasing due to numerous advantages over tracheal intubation. Compared with 1st generation SGAs, 2nd generation SGAs have an added benefit of isolating the airway from the alimentary tract. However, the vertical profile of SGAs may encroach into the surgical field and hence interfere with surgery. We investigated the vertical projections of 1st generation SGAs (LMA Classic, Ambu AuraFlex) and commonly used 2nd generation SGAs in our institution (LMA ProSeal, LMA Supreme, LMA Protector, Ambu AuraGain and I-gel) in a manikin model. Each device was connected to a corrugated catheter mount or angled connector following insertion as per usual clinical practice in our institutions. Vertical projections of all devices were measured from the chin using a centimetre ruler. Securing of airway device to the chin with an adhesive tape was possible for the LMA Classic and Ambu AuraFlex with straight corrugated connector, whereas the stiffer 2nd generations SGAs required the addition of an angled connector or straight corrugated tubing to direct the airway tube caudally, away from the surgical field. The LMA ProSeal had the lowest vertical projection amongst the 2nd generation SGAs and may be the suitable choice for ophthalmic surgery. We also describe a novel technique of utilising a 1st generation SGA with placement of an orogastric tube, although with some reservations. This study has several limitations and transferability of our findings into clinical practice is questionable as the use of a manikin may not fully imitate the real condition of the patient. Our study is the first study comparing vertical projected height of different SGAs in manikin, but future studies should investigate the use of SGA in the clinical setting during ophthalmic surgery. Springer Netherlands 2020-04-09 2021 /pmc/articles/PMC7223643/ /pubmed/32274646 http://dx.doi.org/10.1007/s10877-020-00507-w Text en © Springer Nature B.V. 2020 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Original Research
Seet, Edwin
Zhang, Jinbin
Macachor, Joselo
Kumar, Chandra M.
Choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study
title Choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study
title_full Choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study
title_fullStr Choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study
title_full_unstemmed Choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study
title_short Choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study
title_sort choosing the best supraglottic airway for ophthalmic general anaesthesia: a manikin study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7223643/
https://www.ncbi.nlm.nih.gov/pubmed/32274646
http://dx.doi.org/10.1007/s10877-020-00507-w
work_keys_str_mv AT seetedwin choosingthebestsupraglotticairwayforophthalmicgeneralanaesthesiaamanikinstudy
AT zhangjinbin choosingthebestsupraglotticairwayforophthalmicgeneralanaesthesiaamanikinstudy
AT macachorjoselo choosingthebestsupraglotticairwayforophthalmicgeneralanaesthesiaamanikinstudy
AT kumarchandram choosingthebestsupraglotticairwayforophthalmicgeneralanaesthesiaamanikinstudy