Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants

Transthoracic echocardiogram (TTE) is commonly used to screen for pulmonary hypertension (PHTN) in neonates and young infants. However, in the absence of sufficient tricuspid regurgitation (TR), a ventricular septal defect (VSD), or a patent ductus arteriosus (PDA), the estimation of systolic pulmon...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohammad Nijres, Bassel, Bokowski, John, Mubayed, Lamya, Jafri, Sabih H., Davis, Alan T., Abdulla, Ra-id
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7223795/
https://www.ncbi.nlm.nih.gov/pubmed/31707489
http://dx.doi.org/10.1007/s00246-019-02251-8
_version_ 1783533796205789184
author Mohammad Nijres, Bassel
Bokowski, John
Mubayed, Lamya
Jafri, Sabih H.
Davis, Alan T.
Abdulla, Ra-id
author_facet Mohammad Nijres, Bassel
Bokowski, John
Mubayed, Lamya
Jafri, Sabih H.
Davis, Alan T.
Abdulla, Ra-id
author_sort Mohammad Nijres, Bassel
collection PubMed
description Transthoracic echocardiogram (TTE) is commonly used to screen for pulmonary hypertension (PHTN) in neonates and young infants. However, in the absence of sufficient tricuspid regurgitation (TR), a ventricular septal defect (VSD), or a patent ductus arteriosus (PDA), the estimation of systolic pulmonary artery pressure (SPAP) becomes challenging. Pulmonary artery acceleration time (PAAT) is an alternate parameter that is easy to obtain in almost all patients and does not require the presence of tricuspid valvar regurgitation or an anatomical cardiac defect. We sought to examine the correlation of PAAT with estimated SPAP by TTE and create an equation to estimate the SPAP using PAAT. We performed a retrospective review of TTEs performed on neonates and young infants (4 months of age or younger) at our institution between April 2017 and December 2018, along with the corresponding medical records. We included TTEs that provided estimation for SPAP and at least one PAAT measurement. During the study period, 138 TTEs performed on 82 patients met the inclusion criteria. Strong correlation was delineated between PAAT and SPAP estimated by the maximum velocity of tricuspid valve regurgitation Doppler, correlation coefficient (r) = − 0.83. Moderate correlation was detected between PAAT and SPAP estimated by PDA Doppler, r = − 0.66. Utilizing the following equation “SPAP = 82.6 − 0.58 × PAAT + RA mean pressure”, PAAT can be used to estimate SPAP in neonates and young infants. PAAT can be used as an alternative to TR jet to assess SPAP when the latter is absent or insufficient. Further studies are needed to verify the accuracy of this equation.
format Online
Article
Text
id pubmed-7223795
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-72237952020-05-15 Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants Mohammad Nijres, Bassel Bokowski, John Mubayed, Lamya Jafri, Sabih H. Davis, Alan T. Abdulla, Ra-id Pediatr Cardiol Original Article Transthoracic echocardiogram (TTE) is commonly used to screen for pulmonary hypertension (PHTN) in neonates and young infants. However, in the absence of sufficient tricuspid regurgitation (TR), a ventricular septal defect (VSD), or a patent ductus arteriosus (PDA), the estimation of systolic pulmonary artery pressure (SPAP) becomes challenging. Pulmonary artery acceleration time (PAAT) is an alternate parameter that is easy to obtain in almost all patients and does not require the presence of tricuspid valvar regurgitation or an anatomical cardiac defect. We sought to examine the correlation of PAAT with estimated SPAP by TTE and create an equation to estimate the SPAP using PAAT. We performed a retrospective review of TTEs performed on neonates and young infants (4 months of age or younger) at our institution between April 2017 and December 2018, along with the corresponding medical records. We included TTEs that provided estimation for SPAP and at least one PAAT measurement. During the study period, 138 TTEs performed on 82 patients met the inclusion criteria. Strong correlation was delineated between PAAT and SPAP estimated by the maximum velocity of tricuspid valve regurgitation Doppler, correlation coefficient (r) = − 0.83. Moderate correlation was detected between PAAT and SPAP estimated by PDA Doppler, r = − 0.66. Utilizing the following equation “SPAP = 82.6 − 0.58 × PAAT + RA mean pressure”, PAAT can be used to estimate SPAP in neonates and young infants. PAAT can be used as an alternative to TR jet to assess SPAP when the latter is absent or insufficient. Further studies are needed to verify the accuracy of this equation. Springer US 2019-11-09 2020 /pmc/articles/PMC7223795/ /pubmed/31707489 http://dx.doi.org/10.1007/s00246-019-02251-8 Text en © Springer Science+Business Media, LLC, part of Springer Nature 2019 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Original Article
Mohammad Nijres, Bassel
Bokowski, John
Mubayed, Lamya
Jafri, Sabih H.
Davis, Alan T.
Abdulla, Ra-id
Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants
title Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants
title_full Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants
title_fullStr Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants
title_full_unstemmed Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants
title_short Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants
title_sort utility of pulmonary artery acceleration time to estimate systolic pulmonary artery pressure in neonates and young infants
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7223795/
https://www.ncbi.nlm.nih.gov/pubmed/31707489
http://dx.doi.org/10.1007/s00246-019-02251-8
work_keys_str_mv AT mohammadnijresbassel utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants
AT bokowskijohn utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants
AT mubayedlamya utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants
AT jafrisabihh utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants
AT davisalant utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants
AT abdullaraid utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants