Cargando…
Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants
Transthoracic echocardiogram (TTE) is commonly used to screen for pulmonary hypertension (PHTN) in neonates and young infants. However, in the absence of sufficient tricuspid regurgitation (TR), a ventricular septal defect (VSD), or a patent ductus arteriosus (PDA), the estimation of systolic pulmon...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7223795/ https://www.ncbi.nlm.nih.gov/pubmed/31707489 http://dx.doi.org/10.1007/s00246-019-02251-8 |
_version_ | 1783533796205789184 |
---|---|
author | Mohammad Nijres, Bassel Bokowski, John Mubayed, Lamya Jafri, Sabih H. Davis, Alan T. Abdulla, Ra-id |
author_facet | Mohammad Nijres, Bassel Bokowski, John Mubayed, Lamya Jafri, Sabih H. Davis, Alan T. Abdulla, Ra-id |
author_sort | Mohammad Nijres, Bassel |
collection | PubMed |
description | Transthoracic echocardiogram (TTE) is commonly used to screen for pulmonary hypertension (PHTN) in neonates and young infants. However, in the absence of sufficient tricuspid regurgitation (TR), a ventricular septal defect (VSD), or a patent ductus arteriosus (PDA), the estimation of systolic pulmonary artery pressure (SPAP) becomes challenging. Pulmonary artery acceleration time (PAAT) is an alternate parameter that is easy to obtain in almost all patients and does not require the presence of tricuspid valvar regurgitation or an anatomical cardiac defect. We sought to examine the correlation of PAAT with estimated SPAP by TTE and create an equation to estimate the SPAP using PAAT. We performed a retrospective review of TTEs performed on neonates and young infants (4 months of age or younger) at our institution between April 2017 and December 2018, along with the corresponding medical records. We included TTEs that provided estimation for SPAP and at least one PAAT measurement. During the study period, 138 TTEs performed on 82 patients met the inclusion criteria. Strong correlation was delineated between PAAT and SPAP estimated by the maximum velocity of tricuspid valve regurgitation Doppler, correlation coefficient (r) = − 0.83. Moderate correlation was detected between PAAT and SPAP estimated by PDA Doppler, r = − 0.66. Utilizing the following equation “SPAP = 82.6 − 0.58 × PAAT + RA mean pressure”, PAAT can be used to estimate SPAP in neonates and young infants. PAAT can be used as an alternative to TR jet to assess SPAP when the latter is absent or insufficient. Further studies are needed to verify the accuracy of this equation. |
format | Online Article Text |
id | pubmed-7223795 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-72237952020-05-15 Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants Mohammad Nijres, Bassel Bokowski, John Mubayed, Lamya Jafri, Sabih H. Davis, Alan T. Abdulla, Ra-id Pediatr Cardiol Original Article Transthoracic echocardiogram (TTE) is commonly used to screen for pulmonary hypertension (PHTN) in neonates and young infants. However, in the absence of sufficient tricuspid regurgitation (TR), a ventricular septal defect (VSD), or a patent ductus arteriosus (PDA), the estimation of systolic pulmonary artery pressure (SPAP) becomes challenging. Pulmonary artery acceleration time (PAAT) is an alternate parameter that is easy to obtain in almost all patients and does not require the presence of tricuspid valvar regurgitation or an anatomical cardiac defect. We sought to examine the correlation of PAAT with estimated SPAP by TTE and create an equation to estimate the SPAP using PAAT. We performed a retrospective review of TTEs performed on neonates and young infants (4 months of age or younger) at our institution between April 2017 and December 2018, along with the corresponding medical records. We included TTEs that provided estimation for SPAP and at least one PAAT measurement. During the study period, 138 TTEs performed on 82 patients met the inclusion criteria. Strong correlation was delineated between PAAT and SPAP estimated by the maximum velocity of tricuspid valve regurgitation Doppler, correlation coefficient (r) = − 0.83. Moderate correlation was detected between PAAT and SPAP estimated by PDA Doppler, r = − 0.66. Utilizing the following equation “SPAP = 82.6 − 0.58 × PAAT + RA mean pressure”, PAAT can be used to estimate SPAP in neonates and young infants. PAAT can be used as an alternative to TR jet to assess SPAP when the latter is absent or insufficient. Further studies are needed to verify the accuracy of this equation. Springer US 2019-11-09 2020 /pmc/articles/PMC7223795/ /pubmed/31707489 http://dx.doi.org/10.1007/s00246-019-02251-8 Text en © Springer Science+Business Media, LLC, part of Springer Nature 2019 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Original Article Mohammad Nijres, Bassel Bokowski, John Mubayed, Lamya Jafri, Sabih H. Davis, Alan T. Abdulla, Ra-id Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants |
title | Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants |
title_full | Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants |
title_fullStr | Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants |
title_full_unstemmed | Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants |
title_short | Utility of Pulmonary Artery Acceleration Time to Estimate Systolic Pulmonary Artery Pressure in Neonates and Young Infants |
title_sort | utility of pulmonary artery acceleration time to estimate systolic pulmonary artery pressure in neonates and young infants |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7223795/ https://www.ncbi.nlm.nih.gov/pubmed/31707489 http://dx.doi.org/10.1007/s00246-019-02251-8 |
work_keys_str_mv | AT mohammadnijresbassel utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants AT bokowskijohn utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants AT mubayedlamya utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants AT jafrisabihh utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants AT davisalant utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants AT abdullaraid utilityofpulmonaryarteryaccelerationtimetoestimatesystolicpulmonaryarterypressureinneonatesandyounginfants |