Cargando…

Effects of five levels of noise reduction applied to indirect digital radiography on diagnostic accuracy of external apical root resorption

BACKGROUND: Radiologic diagnosis of external apical root resorption (EARR) is clinically important. Noise might disrupt this diagnosis. Therefore, we assessed the efficacy of noise reduction on periapical indirect digital radiography. MATERIALS AND METHODS: This in vitro study as performed on 792 ra...

Descripción completa

Detalles Bibliográficos
Autores principales: Shoshtari, Sanaz Sharifi, Mohagheghi, Seyed Arman, Farhadi, Nastaran, Kheradmand, Negin, Naderi, Lida
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7224262/
https://www.ncbi.nlm.nih.gov/pubmed/32435435
_version_ 1783533869101744128
author Shoshtari, Sanaz Sharifi
Mohagheghi, Seyed Arman
Farhadi, Nastaran
Kheradmand, Negin
Naderi, Lida
author_facet Shoshtari, Sanaz Sharifi
Mohagheghi, Seyed Arman
Farhadi, Nastaran
Kheradmand, Negin
Naderi, Lida
author_sort Shoshtari, Sanaz Sharifi
collection PubMed
description BACKGROUND: Radiologic diagnosis of external apical root resorption (EARR) is clinically important. Noise might disrupt this diagnosis. Therefore, we assessed the efficacy of noise reduction on periapical indirect digital radiography. MATERIALS AND METHODS: This in vitro study as performed on 792 radiographs. A total of 66 single-rooted premolars were inserted in dried hemimandibles of sheep and fixed with modeling wax. Digital images were obtained using the parallel technique. The storage phosphor plates were processed in the DIGORA Optime scanner. The resulting images were sent to a computer using the Scanora software for radiographic analysis. The teeth were removed from the mandible, and artificial EARR defects were simulated. Afterward, the indirect digital radiographs were obtained at the same condition of the baseline. Five levels of noise reduction were applied. All images were saved in Digital Imaging and Communications in Medicine format and monitored by two observers twice over 2 weeks. Data were analyzed statistically using Cochran and McNemar tests (α = 0.05). RESULTS: The highest sensitivity rate was found in the baseline group (0.99), and the lowest sensitivity was related to the “four-time noise reduction” method (0.91). The highest specificity rate was in the “five-times noise reduction” method (0.88) and the lowest specificity was associated with “one-time noise reduction” method (0.71). There was no statistical difference between images with/without noise reduction enhancement with varied gradation levels in terms of diagnostic accuracies of EARR (P > 0.05). CONCLUSION: Application of noise reduction procedure in Scanora software might have no effect on the accuracy of EARR diagnosis.
format Online
Article
Text
id pubmed-7224262
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-72242622020-05-20 Effects of five levels of noise reduction applied to indirect digital radiography on diagnostic accuracy of external apical root resorption Shoshtari, Sanaz Sharifi Mohagheghi, Seyed Arman Farhadi, Nastaran Kheradmand, Negin Naderi, Lida Dent Res J (Isfahan) Original Article BACKGROUND: Radiologic diagnosis of external apical root resorption (EARR) is clinically important. Noise might disrupt this diagnosis. Therefore, we assessed the efficacy of noise reduction on periapical indirect digital radiography. MATERIALS AND METHODS: This in vitro study as performed on 792 radiographs. A total of 66 single-rooted premolars were inserted in dried hemimandibles of sheep and fixed with modeling wax. Digital images were obtained using the parallel technique. The storage phosphor plates were processed in the DIGORA Optime scanner. The resulting images were sent to a computer using the Scanora software for radiographic analysis. The teeth were removed from the mandible, and artificial EARR defects were simulated. Afterward, the indirect digital radiographs were obtained at the same condition of the baseline. Five levels of noise reduction were applied. All images were saved in Digital Imaging and Communications in Medicine format and monitored by two observers twice over 2 weeks. Data were analyzed statistically using Cochran and McNemar tests (α = 0.05). RESULTS: The highest sensitivity rate was found in the baseline group (0.99), and the lowest sensitivity was related to the “four-time noise reduction” method (0.91). The highest specificity rate was in the “five-times noise reduction” method (0.88) and the lowest specificity was associated with “one-time noise reduction” method (0.71). There was no statistical difference between images with/without noise reduction enhancement with varied gradation levels in terms of diagnostic accuracies of EARR (P > 0.05). CONCLUSION: Application of noise reduction procedure in Scanora software might have no effect on the accuracy of EARR diagnosis. Wolters Kluwer - Medknow 2020-03-17 /pmc/articles/PMC7224262/ /pubmed/32435435 Text en Copyright: © 2020 Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Shoshtari, Sanaz Sharifi
Mohagheghi, Seyed Arman
Farhadi, Nastaran
Kheradmand, Negin
Naderi, Lida
Effects of five levels of noise reduction applied to indirect digital radiography on diagnostic accuracy of external apical root resorption
title Effects of five levels of noise reduction applied to indirect digital radiography on diagnostic accuracy of external apical root resorption
title_full Effects of five levels of noise reduction applied to indirect digital radiography on diagnostic accuracy of external apical root resorption
title_fullStr Effects of five levels of noise reduction applied to indirect digital radiography on diagnostic accuracy of external apical root resorption
title_full_unstemmed Effects of five levels of noise reduction applied to indirect digital radiography on diagnostic accuracy of external apical root resorption
title_short Effects of five levels of noise reduction applied to indirect digital radiography on diagnostic accuracy of external apical root resorption
title_sort effects of five levels of noise reduction applied to indirect digital radiography on diagnostic accuracy of external apical root resorption
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7224262/
https://www.ncbi.nlm.nih.gov/pubmed/32435435
work_keys_str_mv AT shoshtarisanazsharifi effectsoffivelevelsofnoisereductionappliedtoindirectdigitalradiographyondiagnosticaccuracyofexternalapicalrootresorption
AT mohagheghiseyedarman effectsoffivelevelsofnoisereductionappliedtoindirectdigitalradiographyondiagnosticaccuracyofexternalapicalrootresorption
AT farhadinastaran effectsoffivelevelsofnoisereductionappliedtoindirectdigitalradiographyondiagnosticaccuracyofexternalapicalrootresorption
AT kheradmandnegin effectsoffivelevelsofnoisereductionappliedtoindirectdigitalradiographyondiagnosticaccuracyofexternalapicalrootresorption
AT naderilida effectsoffivelevelsofnoisereductionappliedtoindirectdigitalradiographyondiagnosticaccuracyofexternalapicalrootresorption