Monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. A proof of concept study

During general anesthesia (GA), direct analysis of arterial pressure or aortic flow waveforms may be inconclusive in complex situations. Patient-specific biomechanical models, based on data obtained during GA and capable to perform fast simulations of cardiac cycles, have the potential to augment he...

Descripción completa

Detalles Bibliográficos
Autores principales: Le Gall, Arthur, Vallée, Fabrice, Pushparajah, Kuberan, Hussain, Tarique, Mebazaa, Alexandre, Chapelle, Dominique, Gayat, Étienne, Chabiniok, Radomír
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7224549/
https://www.ncbi.nlm.nih.gov/pubmed/32407353
http://dx.doi.org/10.1371/journal.pone.0232830
_version_ 1783533924180295680
author Le Gall, Arthur
Vallée, Fabrice
Pushparajah, Kuberan
Hussain, Tarique
Mebazaa, Alexandre
Chapelle, Dominique
Gayat, Étienne
Chabiniok, Radomír
author_facet Le Gall, Arthur
Vallée, Fabrice
Pushparajah, Kuberan
Hussain, Tarique
Mebazaa, Alexandre
Chapelle, Dominique
Gayat, Étienne
Chabiniok, Radomír
author_sort Le Gall, Arthur
collection PubMed
description During general anesthesia (GA), direct analysis of arterial pressure or aortic flow waveforms may be inconclusive in complex situations. Patient-specific biomechanical models, based on data obtained during GA and capable to perform fast simulations of cardiac cycles, have the potential to augment hemodynamic monitoring. Such models allow to simulate Pressure-Volume (PV) loops and estimate functional indicators of cardiovascular (CV) system, e.g. ventricular-arterial coupling (V(va)), cardiac efficiency (CE) or myocardial contractility, evolving throughout GA. In this prospective observational study, we created patient-specific biomechanical models of heart and vasculature of a reduced geometric complexity for n = 45 patients undergoing GA, while using transthoracic echocardiography and aortic pressure and flow signals acquired in the beginning of GA (baseline condition). If intraoperative hypotension (IOH) appeared, diluted norepinephrine (NOR) was administered and the model readjusted according to the measured aortic pressure and flow signals. Such patients were a posteriori assigned into a so-called hypotensive group. The accuracy of simulated mean aortic pressure (MAP) and stroke volume (SV) at baseline were in accordance with the guidelines for the validation of new devices or reference measurement methods in all patients. After NOR administration in the hypotensive group, the percentage of concordance with 10% exclusion zone between measurement and simulation was >95% for both MAP and SV. The modeling results showed a decreased V(va) (0.64±0.37 vs 0.88±0.43; p = 0.039) and an increased CE (0.8±0.1 vs 0.73±0.11; p = 0.042) in hypotensive vs normotensive patients. Furthermore, V(va) increased by 92±101%, CE decreased by 13±11% (p < 0.001 for both) and contractility increased by 14±11% (p = 0.002) in the hypotensive group post-NOR administration. In this work we demonstrated the application of fast-running patient-specific biophysical models to estimate PV loops and functional indicators of CV system using clinical data available during GA. The work paves the way for model-augmented hemodynamic monitoring at operating theatres or intensive care units to enhance the information on patient-specific physiology.
format Online
Article
Text
id pubmed-7224549
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-72245492020-06-01 Monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. A proof of concept study Le Gall, Arthur Vallée, Fabrice Pushparajah, Kuberan Hussain, Tarique Mebazaa, Alexandre Chapelle, Dominique Gayat, Étienne Chabiniok, Radomír PLoS One Research Article During general anesthesia (GA), direct analysis of arterial pressure or aortic flow waveforms may be inconclusive in complex situations. Patient-specific biomechanical models, based on data obtained during GA and capable to perform fast simulations of cardiac cycles, have the potential to augment hemodynamic monitoring. Such models allow to simulate Pressure-Volume (PV) loops and estimate functional indicators of cardiovascular (CV) system, e.g. ventricular-arterial coupling (V(va)), cardiac efficiency (CE) or myocardial contractility, evolving throughout GA. In this prospective observational study, we created patient-specific biomechanical models of heart and vasculature of a reduced geometric complexity for n = 45 patients undergoing GA, while using transthoracic echocardiography and aortic pressure and flow signals acquired in the beginning of GA (baseline condition). If intraoperative hypotension (IOH) appeared, diluted norepinephrine (NOR) was administered and the model readjusted according to the measured aortic pressure and flow signals. Such patients were a posteriori assigned into a so-called hypotensive group. The accuracy of simulated mean aortic pressure (MAP) and stroke volume (SV) at baseline were in accordance with the guidelines for the validation of new devices or reference measurement methods in all patients. After NOR administration in the hypotensive group, the percentage of concordance with 10% exclusion zone between measurement and simulation was >95% for both MAP and SV. The modeling results showed a decreased V(va) (0.64±0.37 vs 0.88±0.43; p = 0.039) and an increased CE (0.8±0.1 vs 0.73±0.11; p = 0.042) in hypotensive vs normotensive patients. Furthermore, V(va) increased by 92±101%, CE decreased by 13±11% (p < 0.001 for both) and contractility increased by 14±11% (p = 0.002) in the hypotensive group post-NOR administration. In this work we demonstrated the application of fast-running patient-specific biophysical models to estimate PV loops and functional indicators of CV system using clinical data available during GA. The work paves the way for model-augmented hemodynamic monitoring at operating theatres or intensive care units to enhance the information on patient-specific physiology. Public Library of Science 2020-05-14 /pmc/articles/PMC7224549/ /pubmed/32407353 http://dx.doi.org/10.1371/journal.pone.0232830 Text en © 2020 Le Gall et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Le Gall, Arthur
Vallée, Fabrice
Pushparajah, Kuberan
Hussain, Tarique
Mebazaa, Alexandre
Chapelle, Dominique
Gayat, Étienne
Chabiniok, Radomír
Monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. A proof of concept study
title Monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. A proof of concept study
title_full Monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. A proof of concept study
title_fullStr Monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. A proof of concept study
title_full_unstemmed Monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. A proof of concept study
title_short Monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. A proof of concept study
title_sort monitoring of cardiovascular physiology augmented by a patient-specific biomechanical model during general anesthesia. a proof of concept study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7224549/
https://www.ncbi.nlm.nih.gov/pubmed/32407353
http://dx.doi.org/10.1371/journal.pone.0232830
work_keys_str_mv AT legallarthur monitoringofcardiovascularphysiologyaugmentedbyapatientspecificbiomechanicalmodelduringgeneralanesthesiaaproofofconceptstudy
AT valleefabrice monitoringofcardiovascularphysiologyaugmentedbyapatientspecificbiomechanicalmodelduringgeneralanesthesiaaproofofconceptstudy
AT pushparajahkuberan monitoringofcardiovascularphysiologyaugmentedbyapatientspecificbiomechanicalmodelduringgeneralanesthesiaaproofofconceptstudy
AT hussaintarique monitoringofcardiovascularphysiologyaugmentedbyapatientspecificbiomechanicalmodelduringgeneralanesthesiaaproofofconceptstudy
AT mebazaaalexandre monitoringofcardiovascularphysiologyaugmentedbyapatientspecificbiomechanicalmodelduringgeneralanesthesiaaproofofconceptstudy
AT chapelledominique monitoringofcardiovascularphysiologyaugmentedbyapatientspecificbiomechanicalmodelduringgeneralanesthesiaaproofofconceptstudy
AT gayatetienne monitoringofcardiovascularphysiologyaugmentedbyapatientspecificbiomechanicalmodelduringgeneralanesthesiaaproofofconceptstudy
AT chabiniokradomir monitoringofcardiovascularphysiologyaugmentedbyapatientspecificbiomechanicalmodelduringgeneralanesthesiaaproofofconceptstudy