Cargando…

Machine Learning Classification of Articular Cartilage Integrity Using Near Infrared Spectroscopy

INTRODUCTION: Assessment of cartilage integrity during arthroscopy is limited by the subjective visual nature of the technique. To address this shortcoming in diagnostic evaluation of articular cartilage, near infrared spectroscopy (NIRS) has been proposed. In this study, we evaluated the capacity o...

Descripción completa

Detalles Bibliográficos
Autores principales: Afara, Isaac O., Sarin, Jaakko K., Ojanen, Simo, Finnilä, Mikko A. J., Herzog, Walter, Saarakkala, Simo, Korhonen, Rami K., Töyräs, Juha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7225230/
https://www.ncbi.nlm.nih.gov/pubmed/32426059
http://dx.doi.org/10.1007/s12195-020-00612-5
_version_ 1783534045280337920
author Afara, Isaac O.
Sarin, Jaakko K.
Ojanen, Simo
Finnilä, Mikko A. J.
Herzog, Walter
Saarakkala, Simo
Korhonen, Rami K.
Töyräs, Juha
author_facet Afara, Isaac O.
Sarin, Jaakko K.
Ojanen, Simo
Finnilä, Mikko A. J.
Herzog, Walter
Saarakkala, Simo
Korhonen, Rami K.
Töyräs, Juha
author_sort Afara, Isaac O.
collection PubMed
description INTRODUCTION: Assessment of cartilage integrity during arthroscopy is limited by the subjective visual nature of the technique. To address this shortcoming in diagnostic evaluation of articular cartilage, near infrared spectroscopy (NIRS) has been proposed. In this study, we evaluated the capacity of NIRS, combined with machine learning techniques, to classify cartilage integrity. METHODS: Rabbit (n = 14) knee joints with artificial injury, induced via unilateral anterior cruciate ligament transection (ACLT), and the corresponding contra-lateral (CL) joints, including joints from separate non-operated control (CNTRL) animals (n = 8), were used. After sacrifice, NIR spectra (1000–2500 nm) were acquired from different anatomical locations of the joints (n(TOTAL) = 313: n(CNTRL) = 111, n(CL) = 97, n(ACLT) = 105). Machine and deep learning methods (support vector machines–SVM, logistic regression–LR, and deep neural networks–DNN) were then used to develop models for classifying the samples based solely on their NIR spectra. RESULTS: The results show that the model based on SVM is optimal of distinguishing between ACLT and CNTRL samples (ROC_AUC = 0.93, kappa = 0.86), LR is capable of distinguishing between CL and CNTRL samples (ROC_AUC = 0.91, kappa = 0.81), while DNN is optimal for discriminating between the different classes (multi-class classification, kappa = 0.48). CONCLUSION: We show that NIR spectroscopy, when combined with machine learning techniques, is capable of holistic assessment of cartilage integrity, with potential for accurately distinguishing between healthy and diseased cartilage. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s12195-020-00612-5) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-7225230
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-72252302020-05-18 Machine Learning Classification of Articular Cartilage Integrity Using Near Infrared Spectroscopy Afara, Isaac O. Sarin, Jaakko K. Ojanen, Simo Finnilä, Mikko A. J. Herzog, Walter Saarakkala, Simo Korhonen, Rami K. Töyräs, Juha Cell Mol Bioeng Original Article INTRODUCTION: Assessment of cartilage integrity during arthroscopy is limited by the subjective visual nature of the technique. To address this shortcoming in diagnostic evaluation of articular cartilage, near infrared spectroscopy (NIRS) has been proposed. In this study, we evaluated the capacity of NIRS, combined with machine learning techniques, to classify cartilage integrity. METHODS: Rabbit (n = 14) knee joints with artificial injury, induced via unilateral anterior cruciate ligament transection (ACLT), and the corresponding contra-lateral (CL) joints, including joints from separate non-operated control (CNTRL) animals (n = 8), were used. After sacrifice, NIR spectra (1000–2500 nm) were acquired from different anatomical locations of the joints (n(TOTAL) = 313: n(CNTRL) = 111, n(CL) = 97, n(ACLT) = 105). Machine and deep learning methods (support vector machines–SVM, logistic regression–LR, and deep neural networks–DNN) were then used to develop models for classifying the samples based solely on their NIR spectra. RESULTS: The results show that the model based on SVM is optimal of distinguishing between ACLT and CNTRL samples (ROC_AUC = 0.93, kappa = 0.86), LR is capable of distinguishing between CL and CNTRL samples (ROC_AUC = 0.91, kappa = 0.81), while DNN is optimal for discriminating between the different classes (multi-class classification, kappa = 0.48). CONCLUSION: We show that NIR spectroscopy, when combined with machine learning techniques, is capable of holistic assessment of cartilage integrity, with potential for accurately distinguishing between healthy and diseased cartilage. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s12195-020-00612-5) contains supplementary material, which is available to authorized users. Springer International Publishing 2020-03-09 /pmc/articles/PMC7225230/ /pubmed/32426059 http://dx.doi.org/10.1007/s12195-020-00612-5 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Original Article
Afara, Isaac O.
Sarin, Jaakko K.
Ojanen, Simo
Finnilä, Mikko A. J.
Herzog, Walter
Saarakkala, Simo
Korhonen, Rami K.
Töyräs, Juha
Machine Learning Classification of Articular Cartilage Integrity Using Near Infrared Spectroscopy
title Machine Learning Classification of Articular Cartilage Integrity Using Near Infrared Spectroscopy
title_full Machine Learning Classification of Articular Cartilage Integrity Using Near Infrared Spectroscopy
title_fullStr Machine Learning Classification of Articular Cartilage Integrity Using Near Infrared Spectroscopy
title_full_unstemmed Machine Learning Classification of Articular Cartilage Integrity Using Near Infrared Spectroscopy
title_short Machine Learning Classification of Articular Cartilage Integrity Using Near Infrared Spectroscopy
title_sort machine learning classification of articular cartilage integrity using near infrared spectroscopy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7225230/
https://www.ncbi.nlm.nih.gov/pubmed/32426059
http://dx.doi.org/10.1007/s12195-020-00612-5
work_keys_str_mv AT afaraisaaco machinelearningclassificationofarticularcartilageintegrityusingnearinfraredspectroscopy
AT sarinjaakkok machinelearningclassificationofarticularcartilageintegrityusingnearinfraredspectroscopy
AT ojanensimo machinelearningclassificationofarticularcartilageintegrityusingnearinfraredspectroscopy
AT finnilamikkoaj machinelearningclassificationofarticularcartilageintegrityusingnearinfraredspectroscopy
AT herzogwalter machinelearningclassificationofarticularcartilageintegrityusingnearinfraredspectroscopy
AT saarakkalasimo machinelearningclassificationofarticularcartilageintegrityusingnearinfraredspectroscopy
AT korhonenramik machinelearningclassificationofarticularcartilageintegrityusingnearinfraredspectroscopy
AT toyrasjuha machinelearningclassificationofarticularcartilageintegrityusingnearinfraredspectroscopy