Cargando…
Gender Differences in Rates of Arrhythmias, Cardiac Implantable Electronic Devices, and Diagnostic Modalities Among Sarcoidosis Patients
Introduction Sarcoidosis is a granulomatous disease with multiorgan involvement. Cardiac involvement may be asymptomatic or present clinically as heart failure, arrhythmias, or even sudden cardiac death. In this study, we compared gender differences in the prevalence of arrhythmias and associated ou...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7226665/ https://www.ncbi.nlm.nih.gov/pubmed/32419995 http://dx.doi.org/10.7759/cureus.7667 |
_version_ | 1783534339581018112 |
---|---|
author | Durugu, Satya Gonuguntla, Karthik Patil, Shivaraj Rojulpote, Chaitanya Vyata, Vishruth Karambelkar, Pranav Narayanareddy, Pranathi Vuthaluru, Kiranmayi Bhattaru, Abhijit |
author_facet | Durugu, Satya Gonuguntla, Karthik Patil, Shivaraj Rojulpote, Chaitanya Vyata, Vishruth Karambelkar, Pranav Narayanareddy, Pranathi Vuthaluru, Kiranmayi Bhattaru, Abhijit |
author_sort | Durugu, Satya |
collection | PubMed |
description | Introduction Sarcoidosis is a granulomatous disease with multiorgan involvement. Cardiac involvement may be asymptomatic or present clinically as heart failure, arrhythmias, or even sudden cardiac death. In this study, we compared gender differences in the prevalence of arrhythmias and associated outcomes in patients with sarcoidosis without established coronary artery disease. Methods The United States Nationwide Inpatient Sample was queried from 2010 to 2014 to identify patients with sarcoidosis using the International Classification of Diseases, Ninth Revision (ICD-9) diagnosis code in patients >18 years. We excluded patients with a prior history of myocardial infarction, percutaneous coronary intervention, and coronary artery bypass graft. The chi-square test was used for statistical analysis. Results The sample consisted of 308,064 patients (mean age = 55.65 ± 11.28 years); they were mostly women (65.2%) and black (46.7%). In-hospital mortality in this cohort was 2.5%. The most common arrhythmia was atrial fibrillation (9.7%). The prevalence of ventricular fibrillation was 0.2%, ventricular tachycardia 2%, complete heart block 0.5%, and second-degree Mobitz type II (0.1%). Sudden cardiac death occurred in 0.7%. Rates of various cardiac devices implanted were: implantable cardiac defibrillator (ICD) (0.5%), cardiac resynchronization therapy-defibrillator (CRT-D) (0.2%), pacemaker (0.4%). Rates of endomyocardial biopsy (EMB), radionuclide imaging, and cardiac magnetic resonance imaging (MRI) were 0.2%, 0.3%, and 0.1%, respectively. Based on gender (male vs. female), the rates of arrhythmias, cardiac device implantation, and utilization of diagnostic modalities were: atrial fibrillation (41% vs 59%; p<0.001), ventricular fibrillation (50% vs 50%; p=0.983), ventricular tachycardia (55% vs 45%; p<0.001), complete heart block (48% vs 52%; p=0.3), second-degree Mobitz type II (37% vs 63%; p=0.706), sudden cardiac death (38% vs 62%; p<0.171), ICD (56% vs 44%; p<0.001), CRT-D (58% vs 42%; p=0.025), permanent pacemaker (40% vs 60%; p=0.066), EMB (55% vs 45%; p<0.001), radionuclide imaging (32% vs 68%; p=0.403), and cardiac MRI (41% vs 59%; p=0.396). In-hospital mortality was higher in females (64% vs 36%; p<0.001). Conclusion In our study, in-hospital death was more common in females. Females had higher rates of atrial fibrillation as compared to males, who were found to have a higher burden of ventricular tachycardia. Males had higher rates of ICD and CRT-D placement. Males also had EMB performed more commonly than females. |
format | Online Article Text |
id | pubmed-7226665 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-72266652020-05-15 Gender Differences in Rates of Arrhythmias, Cardiac Implantable Electronic Devices, and Diagnostic Modalities Among Sarcoidosis Patients Durugu, Satya Gonuguntla, Karthik Patil, Shivaraj Rojulpote, Chaitanya Vyata, Vishruth Karambelkar, Pranav Narayanareddy, Pranathi Vuthaluru, Kiranmayi Bhattaru, Abhijit Cureus Cardiac/Thoracic/Vascular Surgery Introduction Sarcoidosis is a granulomatous disease with multiorgan involvement. Cardiac involvement may be asymptomatic or present clinically as heart failure, arrhythmias, or even sudden cardiac death. In this study, we compared gender differences in the prevalence of arrhythmias and associated outcomes in patients with sarcoidosis without established coronary artery disease. Methods The United States Nationwide Inpatient Sample was queried from 2010 to 2014 to identify patients with sarcoidosis using the International Classification of Diseases, Ninth Revision (ICD-9) diagnosis code in patients >18 years. We excluded patients with a prior history of myocardial infarction, percutaneous coronary intervention, and coronary artery bypass graft. The chi-square test was used for statistical analysis. Results The sample consisted of 308,064 patients (mean age = 55.65 ± 11.28 years); they were mostly women (65.2%) and black (46.7%). In-hospital mortality in this cohort was 2.5%. The most common arrhythmia was atrial fibrillation (9.7%). The prevalence of ventricular fibrillation was 0.2%, ventricular tachycardia 2%, complete heart block 0.5%, and second-degree Mobitz type II (0.1%). Sudden cardiac death occurred in 0.7%. Rates of various cardiac devices implanted were: implantable cardiac defibrillator (ICD) (0.5%), cardiac resynchronization therapy-defibrillator (CRT-D) (0.2%), pacemaker (0.4%). Rates of endomyocardial biopsy (EMB), radionuclide imaging, and cardiac magnetic resonance imaging (MRI) were 0.2%, 0.3%, and 0.1%, respectively. Based on gender (male vs. female), the rates of arrhythmias, cardiac device implantation, and utilization of diagnostic modalities were: atrial fibrillation (41% vs 59%; p<0.001), ventricular fibrillation (50% vs 50%; p=0.983), ventricular tachycardia (55% vs 45%; p<0.001), complete heart block (48% vs 52%; p=0.3), second-degree Mobitz type II (37% vs 63%; p=0.706), sudden cardiac death (38% vs 62%; p<0.171), ICD (56% vs 44%; p<0.001), CRT-D (58% vs 42%; p=0.025), permanent pacemaker (40% vs 60%; p=0.066), EMB (55% vs 45%; p<0.001), radionuclide imaging (32% vs 68%; p=0.403), and cardiac MRI (41% vs 59%; p=0.396). In-hospital mortality was higher in females (64% vs 36%; p<0.001). Conclusion In our study, in-hospital death was more common in females. Females had higher rates of atrial fibrillation as compared to males, who were found to have a higher burden of ventricular tachycardia. Males had higher rates of ICD and CRT-D placement. Males also had EMB performed more commonly than females. Cureus 2020-04-14 /pmc/articles/PMC7226665/ /pubmed/32419995 http://dx.doi.org/10.7759/cureus.7667 Text en Copyright © 2020, Durugu et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Cardiac/Thoracic/Vascular Surgery Durugu, Satya Gonuguntla, Karthik Patil, Shivaraj Rojulpote, Chaitanya Vyata, Vishruth Karambelkar, Pranav Narayanareddy, Pranathi Vuthaluru, Kiranmayi Bhattaru, Abhijit Gender Differences in Rates of Arrhythmias, Cardiac Implantable Electronic Devices, and Diagnostic Modalities Among Sarcoidosis Patients |
title | Gender Differences in Rates of Arrhythmias, Cardiac Implantable Electronic Devices, and Diagnostic Modalities Among Sarcoidosis Patients |
title_full | Gender Differences in Rates of Arrhythmias, Cardiac Implantable Electronic Devices, and Diagnostic Modalities Among Sarcoidosis Patients |
title_fullStr | Gender Differences in Rates of Arrhythmias, Cardiac Implantable Electronic Devices, and Diagnostic Modalities Among Sarcoidosis Patients |
title_full_unstemmed | Gender Differences in Rates of Arrhythmias, Cardiac Implantable Electronic Devices, and Diagnostic Modalities Among Sarcoidosis Patients |
title_short | Gender Differences in Rates of Arrhythmias, Cardiac Implantable Electronic Devices, and Diagnostic Modalities Among Sarcoidosis Patients |
title_sort | gender differences in rates of arrhythmias, cardiac implantable electronic devices, and diagnostic modalities among sarcoidosis patients |
topic | Cardiac/Thoracic/Vascular Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7226665/ https://www.ncbi.nlm.nih.gov/pubmed/32419995 http://dx.doi.org/10.7759/cureus.7667 |
work_keys_str_mv | AT durugusatya genderdifferencesinratesofarrhythmiascardiacimplantableelectronicdevicesanddiagnosticmodalitiesamongsarcoidosispatients AT gonuguntlakarthik genderdifferencesinratesofarrhythmiascardiacimplantableelectronicdevicesanddiagnosticmodalitiesamongsarcoidosispatients AT patilshivaraj genderdifferencesinratesofarrhythmiascardiacimplantableelectronicdevicesanddiagnosticmodalitiesamongsarcoidosispatients AT rojulpotechaitanya genderdifferencesinratesofarrhythmiascardiacimplantableelectronicdevicesanddiagnosticmodalitiesamongsarcoidosispatients AT vyatavishruth genderdifferencesinratesofarrhythmiascardiacimplantableelectronicdevicesanddiagnosticmodalitiesamongsarcoidosispatients AT karambelkarpranav genderdifferencesinratesofarrhythmiascardiacimplantableelectronicdevicesanddiagnosticmodalitiesamongsarcoidosispatients AT narayanareddypranathi genderdifferencesinratesofarrhythmiascardiacimplantableelectronicdevicesanddiagnosticmodalitiesamongsarcoidosispatients AT vuthalurukiranmayi genderdifferencesinratesofarrhythmiascardiacimplantableelectronicdevicesanddiagnosticmodalitiesamongsarcoidosispatients AT bhattaruabhijit genderdifferencesinratesofarrhythmiascardiacimplantableelectronicdevicesanddiagnosticmodalitiesamongsarcoidosispatients |