Cargando…
Augmented reality-based navigation increases precision of pedicle screw insertion
BACKGROUND: Precise insertion of pedicle screws is important to avoid injury to closely adjacent neurovascular structures. The standard method for the insertion of pedicle screws is based on anatomical landmarks (free-hand technique). Head-mounted augmented reality (AR) devices can be used to guide...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7227090/ https://www.ncbi.nlm.nih.gov/pubmed/32410636 http://dx.doi.org/10.1186/s13018-020-01690-x |
_version_ | 1783534429721853952 |
---|---|
author | Dennler, Cyrill Jaberg, Laurenz Spirig, José Agten, Christoph Götschi, Tobias Fürnstahl, Philipp Farshad, Mazda |
author_facet | Dennler, Cyrill Jaberg, Laurenz Spirig, José Agten, Christoph Götschi, Tobias Fürnstahl, Philipp Farshad, Mazda |
author_sort | Dennler, Cyrill |
collection | PubMed |
description | BACKGROUND: Precise insertion of pedicle screws is important to avoid injury to closely adjacent neurovascular structures. The standard method for the insertion of pedicle screws is based on anatomical landmarks (free-hand technique). Head-mounted augmented reality (AR) devices can be used to guide instrumentation and implant placement in spinal surgery. This study evaluates the feasibility and precision of AR technology to improve precision of pedicle screw insertion compared to the current standard technique. METHODS: Two board-certified orthopedic surgeons specialized in spine surgery and two novice surgeons were each instructed to drill pilot holes for 40 pedicle screws in eighty lumbar vertebra sawbones models in an agar-based gel. One hundred and sixty pedicles were randomized into two groups: the standard free-hand technique (FH) and augmented reality technique (AR). A 3D model of the vertebral body was superimposed over the AR headset. Half of the pedicles were drilled using the FH method, and the other half using the AR method. RESULTS: The average minimal distance of the drill axis to the pedicle wall (MAPW) was similar in both groups for expert surgeons (FH 4.8 ± 1.0 mm vs. AR 5.0 ± 1.4 mm, p = 0.389) but for novice surgeons (FH 3.4 mm ± 1.8 mm, AR 4.2 ± 1.8 mm, p = 0.044). Expert surgeons showed 0 primary drill pedicle perforations (PDPP) in both the FH and AR groups. Novices showed 3 (7.5%) PDPP in the FH group and one perforation (2.5%) in the AR group, respectively (p > 0.005). Experts showed no statistically significant difference in average secondary screw pedicle perforations (SSPP) between the AR and the FH set 6-, 7-, and 8-mm screws (p > 0.05). Novices showed significant differences of SSPP between most groups: 6-mm screws, 18 (45%) vs. 7 (17.5%), p = 0.006; 7-mm screws, 20 (50%) vs. 10 (25%), p = 0.013; and 8-mm screws, 22 (55%) vs. 15 (37.5%), p = 0.053, in the FH and AR group, respectively. In novices, the average optimal medio-lateral convergent angle (oMLCA) was 3.23° (STD 4.90) and 0.62° (STD 4.56) for the FH and AR set screws (p = 0.017), respectively. Novices drilled with a higher precision with respect to the cranio-caudal inclination angle (CCIA) category (p = 0.04) with AR. CONCLUSION: In this study, the additional anatomical information provided by the AR headset superimposed to real-world anatomy improved the precision of drilling pilot holes for pedicle screws in a laboratory setting and decreases the effect of surgeon’s experience. Further technical development and validations studies are currently being performed to investigate potential clinical benefits of the herein described AR-based navigation approach. |
format | Online Article Text |
id | pubmed-7227090 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-72270902020-05-27 Augmented reality-based navigation increases precision of pedicle screw insertion Dennler, Cyrill Jaberg, Laurenz Spirig, José Agten, Christoph Götschi, Tobias Fürnstahl, Philipp Farshad, Mazda J Orthop Surg Res Research Article BACKGROUND: Precise insertion of pedicle screws is important to avoid injury to closely adjacent neurovascular structures. The standard method for the insertion of pedicle screws is based on anatomical landmarks (free-hand technique). Head-mounted augmented reality (AR) devices can be used to guide instrumentation and implant placement in spinal surgery. This study evaluates the feasibility and precision of AR technology to improve precision of pedicle screw insertion compared to the current standard technique. METHODS: Two board-certified orthopedic surgeons specialized in spine surgery and two novice surgeons were each instructed to drill pilot holes for 40 pedicle screws in eighty lumbar vertebra sawbones models in an agar-based gel. One hundred and sixty pedicles were randomized into two groups: the standard free-hand technique (FH) and augmented reality technique (AR). A 3D model of the vertebral body was superimposed over the AR headset. Half of the pedicles were drilled using the FH method, and the other half using the AR method. RESULTS: The average minimal distance of the drill axis to the pedicle wall (MAPW) was similar in both groups for expert surgeons (FH 4.8 ± 1.0 mm vs. AR 5.0 ± 1.4 mm, p = 0.389) but for novice surgeons (FH 3.4 mm ± 1.8 mm, AR 4.2 ± 1.8 mm, p = 0.044). Expert surgeons showed 0 primary drill pedicle perforations (PDPP) in both the FH and AR groups. Novices showed 3 (7.5%) PDPP in the FH group and one perforation (2.5%) in the AR group, respectively (p > 0.005). Experts showed no statistically significant difference in average secondary screw pedicle perforations (SSPP) between the AR and the FH set 6-, 7-, and 8-mm screws (p > 0.05). Novices showed significant differences of SSPP between most groups: 6-mm screws, 18 (45%) vs. 7 (17.5%), p = 0.006; 7-mm screws, 20 (50%) vs. 10 (25%), p = 0.013; and 8-mm screws, 22 (55%) vs. 15 (37.5%), p = 0.053, in the FH and AR group, respectively. In novices, the average optimal medio-lateral convergent angle (oMLCA) was 3.23° (STD 4.90) and 0.62° (STD 4.56) for the FH and AR set screws (p = 0.017), respectively. Novices drilled with a higher precision with respect to the cranio-caudal inclination angle (CCIA) category (p = 0.04) with AR. CONCLUSION: In this study, the additional anatomical information provided by the AR headset superimposed to real-world anatomy improved the precision of drilling pilot holes for pedicle screws in a laboratory setting and decreases the effect of surgeon’s experience. Further technical development and validations studies are currently being performed to investigate potential clinical benefits of the herein described AR-based navigation approach. BioMed Central 2020-05-14 /pmc/articles/PMC7227090/ /pubmed/32410636 http://dx.doi.org/10.1186/s13018-020-01690-x Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Dennler, Cyrill Jaberg, Laurenz Spirig, José Agten, Christoph Götschi, Tobias Fürnstahl, Philipp Farshad, Mazda Augmented reality-based navigation increases precision of pedicle screw insertion |
title | Augmented reality-based navigation increases precision of pedicle screw insertion |
title_full | Augmented reality-based navigation increases precision of pedicle screw insertion |
title_fullStr | Augmented reality-based navigation increases precision of pedicle screw insertion |
title_full_unstemmed | Augmented reality-based navigation increases precision of pedicle screw insertion |
title_short | Augmented reality-based navigation increases precision of pedicle screw insertion |
title_sort | augmented reality-based navigation increases precision of pedicle screw insertion |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7227090/ https://www.ncbi.nlm.nih.gov/pubmed/32410636 http://dx.doi.org/10.1186/s13018-020-01690-x |
work_keys_str_mv | AT dennlercyrill augmentedrealitybasednavigationincreasesprecisionofpediclescrewinsertion AT jaberglaurenz augmentedrealitybasednavigationincreasesprecisionofpediclescrewinsertion AT spirigjose augmentedrealitybasednavigationincreasesprecisionofpediclescrewinsertion AT agtenchristoph augmentedrealitybasednavigationincreasesprecisionofpediclescrewinsertion AT gotschitobias augmentedrealitybasednavigationincreasesprecisionofpediclescrewinsertion AT furnstahlphilipp augmentedrealitybasednavigationincreasesprecisionofpediclescrewinsertion AT farshadmazda augmentedrealitybasednavigationincreasesprecisionofpediclescrewinsertion |