Cargando…
Inter-study repeatability of circumferential strain and diastolic strain rate by CMR tagging, feature tracking and tissue tracking in ST-segment elevation myocardial infarction
Strain assessment allows accurate evaluation of myocardial function and mechanics in ST-segment elevation myocardial infarction (STEMI). Strain using cardiovascular magnetic resonance (CMR) has traditionally been assessed with tagging but limitations of this technique have led to more widespread use...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7228913/ https://www.ncbi.nlm.nih.gov/pubmed/32152811 http://dx.doi.org/10.1007/s10554-020-01806-8 |
_version_ | 1783534657643479040 |
---|---|
author | Nazir, Sheraz A. Shetye, Abhishek M. Khan, Jamal N. Singh, Anvesha Arnold, Jayanth R. Squire, Iain McCann, Gerry P. |
author_facet | Nazir, Sheraz A. Shetye, Abhishek M. Khan, Jamal N. Singh, Anvesha Arnold, Jayanth R. Squire, Iain McCann, Gerry P. |
author_sort | Nazir, Sheraz A. |
collection | PubMed |
description | Strain assessment allows accurate evaluation of myocardial function and mechanics in ST-segment elevation myocardial infarction (STEMI). Strain using cardiovascular magnetic resonance (CMR) has traditionally been assessed with tagging but limitations of this technique have led to more widespread use of alternative methods, which may be more robust. We compared the inter-study repeatability of circumferential global peak-systolic strain (Ecc) and peak-early diastolic strain rate (PEDSR) derived by tagging with values obtained using novel cine-based software: Feature Tracking (FT) (TomTec, Germany) and Tissue Tracking (TT) (Circle cvi(42), Canada) in patients following STEMI. Twenty male patients (mean age 56 ± 10 years, mean infarct size 13.7 ± 7.1% of left ventricular mass) were randomised to undergo CMR 1–5 days post-STEMI at 1.5 T or 3.0 T, repeated after ten minutes at the same field strength. Ecc and PEDSR were assessed using tagging, FT and TT. Inter-study repeatability was evaluated using Bland–Altman analyses, coefficients of variation (CoV) and intra-class correlation coefficient (ICC). Ecc (%) was significantly lower with tagging than with FT or TT at 1.5 T (− 9.5 ± 3.3 vs. − 17.5 ± 3.8 vs. −15.5 ± 5.2, respectively, p < 0.001) and 3.0 T (− 13.1 ± 1.8 vs. − 19.4 ± 2.9 vs. − 17.3 ± 2.1, respectively, p = 0.001). This was similar for PEDSR (.s(−1)): 1.5 T (0.6 ± 0.2 vs. 1.5 ± 0.4 vs. 1.0 ± 0.4, for tagging, FT and TT respectively, p < 0.001) and 3.0 T (0.6 ± 0.2 vs. 1.5 ± 0.3 vs. 0.9 ± 0.3, respectively, p < 0.001). Inter-study repeatability for Ecc at 1.5 T was good for tagging and excellent for FT and TT: CoV 16.7%, 6.38%, and 8.65%, respectively. Repeatability for Ecc at 3.0 T was good for all three techniques: CoV 14.4%, 11.2%, and 13.0%, respectively. However, repeatability of PEDSR was generally lower than that for Ecc at 1.5 T (CoV 15.1%, 13.1%, and 34.0% for tagging, FT and TT, respectively) and 3.0 T (CoV 23.0%, 18.6%, and 26.2%, respectively). Following STEMI, Ecc and PEDSR are higher when measured with FT and TT than with tagging. Inter-study repeatability of Ecc is good for tagging, excellent for FT and TT at 1.5 T, and good for all three methods at 3.0 T. The repeatability of PEDSR is good to moderate at 1.5 T and moderate at 3.0 T. Cine-based methods to assess Ecc following STEMI may be preferable to tagging. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10554-020-01806-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-7228913 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-72289132020-05-18 Inter-study repeatability of circumferential strain and diastolic strain rate by CMR tagging, feature tracking and tissue tracking in ST-segment elevation myocardial infarction Nazir, Sheraz A. Shetye, Abhishek M. Khan, Jamal N. Singh, Anvesha Arnold, Jayanth R. Squire, Iain McCann, Gerry P. Int J Cardiovasc Imaging Original Paper Strain assessment allows accurate evaluation of myocardial function and mechanics in ST-segment elevation myocardial infarction (STEMI). Strain using cardiovascular magnetic resonance (CMR) has traditionally been assessed with tagging but limitations of this technique have led to more widespread use of alternative methods, which may be more robust. We compared the inter-study repeatability of circumferential global peak-systolic strain (Ecc) and peak-early diastolic strain rate (PEDSR) derived by tagging with values obtained using novel cine-based software: Feature Tracking (FT) (TomTec, Germany) and Tissue Tracking (TT) (Circle cvi(42), Canada) in patients following STEMI. Twenty male patients (mean age 56 ± 10 years, mean infarct size 13.7 ± 7.1% of left ventricular mass) were randomised to undergo CMR 1–5 days post-STEMI at 1.5 T or 3.0 T, repeated after ten minutes at the same field strength. Ecc and PEDSR were assessed using tagging, FT and TT. Inter-study repeatability was evaluated using Bland–Altman analyses, coefficients of variation (CoV) and intra-class correlation coefficient (ICC). Ecc (%) was significantly lower with tagging than with FT or TT at 1.5 T (− 9.5 ± 3.3 vs. − 17.5 ± 3.8 vs. −15.5 ± 5.2, respectively, p < 0.001) and 3.0 T (− 13.1 ± 1.8 vs. − 19.4 ± 2.9 vs. − 17.3 ± 2.1, respectively, p = 0.001). This was similar for PEDSR (.s(−1)): 1.5 T (0.6 ± 0.2 vs. 1.5 ± 0.4 vs. 1.0 ± 0.4, for tagging, FT and TT respectively, p < 0.001) and 3.0 T (0.6 ± 0.2 vs. 1.5 ± 0.3 vs. 0.9 ± 0.3, respectively, p < 0.001). Inter-study repeatability for Ecc at 1.5 T was good for tagging and excellent for FT and TT: CoV 16.7%, 6.38%, and 8.65%, respectively. Repeatability for Ecc at 3.0 T was good for all three techniques: CoV 14.4%, 11.2%, and 13.0%, respectively. However, repeatability of PEDSR was generally lower than that for Ecc at 1.5 T (CoV 15.1%, 13.1%, and 34.0% for tagging, FT and TT, respectively) and 3.0 T (CoV 23.0%, 18.6%, and 26.2%, respectively). Following STEMI, Ecc and PEDSR are higher when measured with FT and TT than with tagging. Inter-study repeatability of Ecc is good for tagging, excellent for FT and TT at 1.5 T, and good for all three methods at 3.0 T. The repeatability of PEDSR is good to moderate at 1.5 T and moderate at 3.0 T. Cine-based methods to assess Ecc following STEMI may be preferable to tagging. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10554-020-01806-8) contains supplementary material, which is available to authorized users. Springer Netherlands 2020-03-09 2020 /pmc/articles/PMC7228913/ /pubmed/32152811 http://dx.doi.org/10.1007/s10554-020-01806-8 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Original Paper Nazir, Sheraz A. Shetye, Abhishek M. Khan, Jamal N. Singh, Anvesha Arnold, Jayanth R. Squire, Iain McCann, Gerry P. Inter-study repeatability of circumferential strain and diastolic strain rate by CMR tagging, feature tracking and tissue tracking in ST-segment elevation myocardial infarction |
title | Inter-study repeatability of circumferential strain and diastolic strain rate by CMR tagging, feature tracking and tissue tracking in ST-segment elevation myocardial infarction |
title_full | Inter-study repeatability of circumferential strain and diastolic strain rate by CMR tagging, feature tracking and tissue tracking in ST-segment elevation myocardial infarction |
title_fullStr | Inter-study repeatability of circumferential strain and diastolic strain rate by CMR tagging, feature tracking and tissue tracking in ST-segment elevation myocardial infarction |
title_full_unstemmed | Inter-study repeatability of circumferential strain and diastolic strain rate by CMR tagging, feature tracking and tissue tracking in ST-segment elevation myocardial infarction |
title_short | Inter-study repeatability of circumferential strain and diastolic strain rate by CMR tagging, feature tracking and tissue tracking in ST-segment elevation myocardial infarction |
title_sort | inter-study repeatability of circumferential strain and diastolic strain rate by cmr tagging, feature tracking and tissue tracking in st-segment elevation myocardial infarction |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7228913/ https://www.ncbi.nlm.nih.gov/pubmed/32152811 http://dx.doi.org/10.1007/s10554-020-01806-8 |
work_keys_str_mv | AT nazirsheraza interstudyrepeatabilityofcircumferentialstrainanddiastolicstrainratebycmrtaggingfeaturetrackingandtissuetrackinginstsegmentelevationmyocardialinfarction AT shetyeabhishekm interstudyrepeatabilityofcircumferentialstrainanddiastolicstrainratebycmrtaggingfeaturetrackingandtissuetrackinginstsegmentelevationmyocardialinfarction AT khanjamaln interstudyrepeatabilityofcircumferentialstrainanddiastolicstrainratebycmrtaggingfeaturetrackingandtissuetrackinginstsegmentelevationmyocardialinfarction AT singhanvesha interstudyrepeatabilityofcircumferentialstrainanddiastolicstrainratebycmrtaggingfeaturetrackingandtissuetrackinginstsegmentelevationmyocardialinfarction AT arnoldjayanthr interstudyrepeatabilityofcircumferentialstrainanddiastolicstrainratebycmrtaggingfeaturetrackingandtissuetrackinginstsegmentelevationmyocardialinfarction AT squireiain interstudyrepeatabilityofcircumferentialstrainanddiastolicstrainratebycmrtaggingfeaturetrackingandtissuetrackinginstsegmentelevationmyocardialinfarction AT mccanngerryp interstudyrepeatabilityofcircumferentialstrainanddiastolicstrainratebycmrtaggingfeaturetrackingandtissuetrackinginstsegmentelevationmyocardialinfarction |