Cargando…

Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery

PURPOSE: The goal of this work was to evaluate the low-frequency hearing preservation of long electrode array cochlear implant (CI) recipients. METHOD: Twenty-five participants presented with an unaided hearing threshold of ≤ 80 dB HL at 125 Hz pre-operatively in the ear to be implanted. Participant...

Descripción completa

Detalles Bibliográficos
Autores principales: Dillon, Margaret T., Buss, Emily, O'Connell, Brendan P., Rooth, Meredith A., King, English R., Bucker, Andrea L., Deres, Ellen J., McCarthy, Sarah A., Pillsbury, Harold C., Brown, Kevin D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Speech-Language-Hearing Association 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7229778/
https://www.ncbi.nlm.nih.gov/pubmed/31835906
http://dx.doi.org/10.1044/2019_AJA-19-00045
_version_ 1783534820457971712
author Dillon, Margaret T.
Buss, Emily
O'Connell, Brendan P.
Rooth, Meredith A.
King, English R.
Bucker, Andrea L.
Deres, Ellen J.
McCarthy, Sarah A.
Pillsbury, Harold C.
Brown, Kevin D.
author_facet Dillon, Margaret T.
Buss, Emily
O'Connell, Brendan P.
Rooth, Meredith A.
King, English R.
Bucker, Andrea L.
Deres, Ellen J.
McCarthy, Sarah A.
Pillsbury, Harold C.
Brown, Kevin D.
author_sort Dillon, Margaret T.
collection PubMed
description PURPOSE: The goal of this work was to evaluate the low-frequency hearing preservation of long electrode array cochlear implant (CI) recipients. METHOD: Twenty-five participants presented with an unaided hearing threshold of ≤ 80 dB HL at 125 Hz pre-operatively in the ear to be implanted. Participants were implanted with a long (31.5-mm) electrode array. The unaided hearing threshold at 125 Hz was compared between the preoperative and postoperative intervals (i.e., initial CI activation, and 1, 3, 6, 9, and 12 months after activation). RESULTS: Eight participants maintained an unaided hearing threshold of ≤ 80 dB HL at 125 Hz postoperatively. The majority (n = 5) demonstrated aidable low-frequency hearing at initial activation, whereas 3 other participants experienced an improvement in unaided low-frequency hearing thresholds at subsequent intervals. CONCLUSIONS: CI recipients can retain residual hearing sensitivity with fully inserted long electrode arrays, and low-frequency hearing thresholds may improve during the postoperative period. Therefore, unaided hearing thresholds obtained within the initial weeks after surgery may not reflect later hearing sensitivity. Routine measurement of postoperative unaided hearing thresholds—even for patients who did not demonstrate aidable hearing thresholds initially after cochlear implantation—will identify CI recipients who may benefit from electric–acoustic stimulation. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.11356637
format Online
Article
Text
id pubmed-7229778
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Speech-Language-Hearing Association
record_format MEDLINE/PubMed
spelling pubmed-72297782020-09-01 Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery Dillon, Margaret T. Buss, Emily O'Connell, Brendan P. Rooth, Meredith A. King, English R. Bucker, Andrea L. Deres, Ellen J. McCarthy, Sarah A. Pillsbury, Harold C. Brown, Kevin D. Am J Audiol Clinical Focus PURPOSE: The goal of this work was to evaluate the low-frequency hearing preservation of long electrode array cochlear implant (CI) recipients. METHOD: Twenty-five participants presented with an unaided hearing threshold of ≤ 80 dB HL at 125 Hz pre-operatively in the ear to be implanted. Participants were implanted with a long (31.5-mm) electrode array. The unaided hearing threshold at 125 Hz was compared between the preoperative and postoperative intervals (i.e., initial CI activation, and 1, 3, 6, 9, and 12 months after activation). RESULTS: Eight participants maintained an unaided hearing threshold of ≤ 80 dB HL at 125 Hz postoperatively. The majority (n = 5) demonstrated aidable low-frequency hearing at initial activation, whereas 3 other participants experienced an improvement in unaided low-frequency hearing thresholds at subsequent intervals. CONCLUSIONS: CI recipients can retain residual hearing sensitivity with fully inserted long electrode arrays, and low-frequency hearing thresholds may improve during the postoperative period. Therefore, unaided hearing thresholds obtained within the initial weeks after surgery may not reflect later hearing sensitivity. Routine measurement of postoperative unaided hearing thresholds—even for patients who did not demonstrate aidable hearing thresholds initially after cochlear implantation—will identify CI recipients who may benefit from electric–acoustic stimulation. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.11356637 American Speech-Language-Hearing Association 2020-03 2019-12-13 /pmc/articles/PMC7229778/ /pubmed/31835906 http://dx.doi.org/10.1044/2019_AJA-19-00045 Text en Copyright © 2019 The Authors http://creativecommons.org/licenses/by-nd/4.0/ This work is licensed under a Creative Commons Attribution-NoDerivatives 4.0 International License (http://creativecommons.org/licenses/by-nd/4.0/) .
spellingShingle Clinical Focus
Dillon, Margaret T.
Buss, Emily
O'Connell, Brendan P.
Rooth, Meredith A.
King, English R.
Bucker, Andrea L.
Deres, Ellen J.
McCarthy, Sarah A.
Pillsbury, Harold C.
Brown, Kevin D.
Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery
title Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery
title_full Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery
title_fullStr Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery
title_full_unstemmed Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery
title_short Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery
title_sort low-frequency hearing preservation with long electrode arrays: inclusion of unaided hearing threshold assessment in the postoperative test battery
topic Clinical Focus
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7229778/
https://www.ncbi.nlm.nih.gov/pubmed/31835906
http://dx.doi.org/10.1044/2019_AJA-19-00045
work_keys_str_mv AT dillonmargarett lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery
AT bussemily lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery
AT oconnellbrendanp lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery
AT roothmereditha lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery
AT kingenglishr lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery
AT buckerandreal lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery
AT deresellenj lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery
AT mccarthysaraha lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery
AT pillsburyharoldc lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery
AT brownkevind lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery