Cargando…
Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery
PURPOSE: The goal of this work was to evaluate the low-frequency hearing preservation of long electrode array cochlear implant (CI) recipients. METHOD: Twenty-five participants presented with an unaided hearing threshold of ≤ 80 dB HL at 125 Hz pre-operatively in the ear to be implanted. Participant...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Speech-Language-Hearing Association
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7229778/ https://www.ncbi.nlm.nih.gov/pubmed/31835906 http://dx.doi.org/10.1044/2019_AJA-19-00045 |
_version_ | 1783534820457971712 |
---|---|
author | Dillon, Margaret T. Buss, Emily O'Connell, Brendan P. Rooth, Meredith A. King, English R. Bucker, Andrea L. Deres, Ellen J. McCarthy, Sarah A. Pillsbury, Harold C. Brown, Kevin D. |
author_facet | Dillon, Margaret T. Buss, Emily O'Connell, Brendan P. Rooth, Meredith A. King, English R. Bucker, Andrea L. Deres, Ellen J. McCarthy, Sarah A. Pillsbury, Harold C. Brown, Kevin D. |
author_sort | Dillon, Margaret T. |
collection | PubMed |
description | PURPOSE: The goal of this work was to evaluate the low-frequency hearing preservation of long electrode array cochlear implant (CI) recipients. METHOD: Twenty-five participants presented with an unaided hearing threshold of ≤ 80 dB HL at 125 Hz pre-operatively in the ear to be implanted. Participants were implanted with a long (31.5-mm) electrode array. The unaided hearing threshold at 125 Hz was compared between the preoperative and postoperative intervals (i.e., initial CI activation, and 1, 3, 6, 9, and 12 months after activation). RESULTS: Eight participants maintained an unaided hearing threshold of ≤ 80 dB HL at 125 Hz postoperatively. The majority (n = 5) demonstrated aidable low-frequency hearing at initial activation, whereas 3 other participants experienced an improvement in unaided low-frequency hearing thresholds at subsequent intervals. CONCLUSIONS: CI recipients can retain residual hearing sensitivity with fully inserted long electrode arrays, and low-frequency hearing thresholds may improve during the postoperative period. Therefore, unaided hearing thresholds obtained within the initial weeks after surgery may not reflect later hearing sensitivity. Routine measurement of postoperative unaided hearing thresholds—even for patients who did not demonstrate aidable hearing thresholds initially after cochlear implantation—will identify CI recipients who may benefit from electric–acoustic stimulation. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.11356637 |
format | Online Article Text |
id | pubmed-7229778 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | American Speech-Language-Hearing Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-72297782020-09-01 Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery Dillon, Margaret T. Buss, Emily O'Connell, Brendan P. Rooth, Meredith A. King, English R. Bucker, Andrea L. Deres, Ellen J. McCarthy, Sarah A. Pillsbury, Harold C. Brown, Kevin D. Am J Audiol Clinical Focus PURPOSE: The goal of this work was to evaluate the low-frequency hearing preservation of long electrode array cochlear implant (CI) recipients. METHOD: Twenty-five participants presented with an unaided hearing threshold of ≤ 80 dB HL at 125 Hz pre-operatively in the ear to be implanted. Participants were implanted with a long (31.5-mm) electrode array. The unaided hearing threshold at 125 Hz was compared between the preoperative and postoperative intervals (i.e., initial CI activation, and 1, 3, 6, 9, and 12 months after activation). RESULTS: Eight participants maintained an unaided hearing threshold of ≤ 80 dB HL at 125 Hz postoperatively. The majority (n = 5) demonstrated aidable low-frequency hearing at initial activation, whereas 3 other participants experienced an improvement in unaided low-frequency hearing thresholds at subsequent intervals. CONCLUSIONS: CI recipients can retain residual hearing sensitivity with fully inserted long electrode arrays, and low-frequency hearing thresholds may improve during the postoperative period. Therefore, unaided hearing thresholds obtained within the initial weeks after surgery may not reflect later hearing sensitivity. Routine measurement of postoperative unaided hearing thresholds—even for patients who did not demonstrate aidable hearing thresholds initially after cochlear implantation—will identify CI recipients who may benefit from electric–acoustic stimulation. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.11356637 American Speech-Language-Hearing Association 2020-03 2019-12-13 /pmc/articles/PMC7229778/ /pubmed/31835906 http://dx.doi.org/10.1044/2019_AJA-19-00045 Text en Copyright © 2019 The Authors http://creativecommons.org/licenses/by-nd/4.0/ This work is licensed under a Creative Commons Attribution-NoDerivatives 4.0 International License (http://creativecommons.org/licenses/by-nd/4.0/) . |
spellingShingle | Clinical Focus Dillon, Margaret T. Buss, Emily O'Connell, Brendan P. Rooth, Meredith A. King, English R. Bucker, Andrea L. Deres, Ellen J. McCarthy, Sarah A. Pillsbury, Harold C. Brown, Kevin D. Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery |
title | Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery |
title_full | Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery |
title_fullStr | Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery |
title_full_unstemmed | Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery |
title_short | Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery |
title_sort | low-frequency hearing preservation with long electrode arrays: inclusion of unaided hearing threshold assessment in the postoperative test battery |
topic | Clinical Focus |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7229778/ https://www.ncbi.nlm.nih.gov/pubmed/31835906 http://dx.doi.org/10.1044/2019_AJA-19-00045 |
work_keys_str_mv | AT dillonmargarett lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery AT bussemily lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery AT oconnellbrendanp lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery AT roothmereditha lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery AT kingenglishr lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery AT buckerandreal lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery AT deresellenj lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery AT mccarthysaraha lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery AT pillsburyharoldc lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery AT brownkevind lowfrequencyhearingpreservationwithlongelectrodearraysinclusionofunaidedhearingthresholdassessmentinthepostoperativetestbattery |