Cargando…

Microfluidic-RT-LAMP chip for the point-of-care detection of emerging and re-emerging enteric coronaviruses in swine

Porcine epidemic diarrhea virus (PEDV), porcine deltacoronavirus (PDCoV), and swine acute diarrhea syndrome-coronavirus (SADS-CoV) are three emerging and re-emerging coronaviruses (CoVs). Symptoms caused by these three viruses are extremely similar, including acute diarrhea, vomiting and even death...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Ling, Chen, Yonghui, Fang, Xueen, Liu, Yanhong, Du, Mengkan, Lu, Xiandong, Li, Qianniu, Sun, Yuan, Ma, Jingyun, Lan, Tian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier B.V. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7234951/
https://www.ncbi.nlm.nih.gov/pubmed/32674781
http://dx.doi.org/10.1016/j.aca.2020.05.034
_version_ 1783535870854299648
author Zhou, Ling
Chen, Yonghui
Fang, Xueen
Liu, Yanhong
Du, Mengkan
Lu, Xiandong
Li, Qianniu
Sun, Yuan
Ma, Jingyun
Lan, Tian
author_facet Zhou, Ling
Chen, Yonghui
Fang, Xueen
Liu, Yanhong
Du, Mengkan
Lu, Xiandong
Li, Qianniu
Sun, Yuan
Ma, Jingyun
Lan, Tian
author_sort Zhou, Ling
collection PubMed
description Porcine epidemic diarrhea virus (PEDV), porcine deltacoronavirus (PDCoV), and swine acute diarrhea syndrome-coronavirus (SADS-CoV) are three emerging and re-emerging coronaviruses (CoVs). Symptoms caused by these three viruses are extremely similar, including acute diarrhea, vomiting and even death in piglets. To date, strict biosecurity is still the most effective disease prevention and control measures, and the early detection of pathogens is the most important link. Here, we developed a microfluidic-RT-LAMP chip detection system for the first time, which could detected PEDV, PDCoV and SADS-CoV simultaneously, and had advantages of rapid, simple, sensitive, high-throughput, and accurate at point-of-care settings. The lowest detection limits of the microfluidic-RT-LAMP chip method are 10(1) copies/μL, 10(2) copies/μL and 10(2) copies/μL for PEDV, PDCoV and SADS-CoV, respectively. The whole detection procedure can be finished rapidly in 40 min without any cross-reaction with other common swine viruses. A total of 173 clinical swine fecal samples characterized with diarrheal symptoms were used to evaluate the performance of the newly developed system, which presented good stabilities (C.V.s<5%) and specificities (100%), and possessed sensitivities of 92.24%, 92.19% and 91.23% for PEDV, PDCoV and SADS-CoV respectively. In summary, the established microfluidic-RT-LAMP chip detection system could satisfy the demanding in field diagnoses, which was suitable for promotion in remote areas due to its fast, portable and cost-effective characters.
format Online
Article
Text
id pubmed-7234951
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier B.V.
record_format MEDLINE/PubMed
spelling pubmed-72349512020-05-19 Microfluidic-RT-LAMP chip for the point-of-care detection of emerging and re-emerging enteric coronaviruses in swine Zhou, Ling Chen, Yonghui Fang, Xueen Liu, Yanhong Du, Mengkan Lu, Xiandong Li, Qianniu Sun, Yuan Ma, Jingyun Lan, Tian Anal Chim Acta Article Porcine epidemic diarrhea virus (PEDV), porcine deltacoronavirus (PDCoV), and swine acute diarrhea syndrome-coronavirus (SADS-CoV) are three emerging and re-emerging coronaviruses (CoVs). Symptoms caused by these three viruses are extremely similar, including acute diarrhea, vomiting and even death in piglets. To date, strict biosecurity is still the most effective disease prevention and control measures, and the early detection of pathogens is the most important link. Here, we developed a microfluidic-RT-LAMP chip detection system for the first time, which could detected PEDV, PDCoV and SADS-CoV simultaneously, and had advantages of rapid, simple, sensitive, high-throughput, and accurate at point-of-care settings. The lowest detection limits of the microfluidic-RT-LAMP chip method are 10(1) copies/μL, 10(2) copies/μL and 10(2) copies/μL for PEDV, PDCoV and SADS-CoV, respectively. The whole detection procedure can be finished rapidly in 40 min without any cross-reaction with other common swine viruses. A total of 173 clinical swine fecal samples characterized with diarrheal symptoms were used to evaluate the performance of the newly developed system, which presented good stabilities (C.V.s<5%) and specificities (100%), and possessed sensitivities of 92.24%, 92.19% and 91.23% for PEDV, PDCoV and SADS-CoV respectively. In summary, the established microfluidic-RT-LAMP chip detection system could satisfy the demanding in field diagnoses, which was suitable for promotion in remote areas due to its fast, portable and cost-effective characters. Elsevier B.V. 2020-08-15 2020-05-19 /pmc/articles/PMC7234951/ /pubmed/32674781 http://dx.doi.org/10.1016/j.aca.2020.05.034 Text en © 2020 Elsevier B.V. All rights reserved. Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active.
spellingShingle Article
Zhou, Ling
Chen, Yonghui
Fang, Xueen
Liu, Yanhong
Du, Mengkan
Lu, Xiandong
Li, Qianniu
Sun, Yuan
Ma, Jingyun
Lan, Tian
Microfluidic-RT-LAMP chip for the point-of-care detection of emerging and re-emerging enteric coronaviruses in swine
title Microfluidic-RT-LAMP chip for the point-of-care detection of emerging and re-emerging enteric coronaviruses in swine
title_full Microfluidic-RT-LAMP chip for the point-of-care detection of emerging and re-emerging enteric coronaviruses in swine
title_fullStr Microfluidic-RT-LAMP chip for the point-of-care detection of emerging and re-emerging enteric coronaviruses in swine
title_full_unstemmed Microfluidic-RT-LAMP chip for the point-of-care detection of emerging and re-emerging enteric coronaviruses in swine
title_short Microfluidic-RT-LAMP chip for the point-of-care detection of emerging and re-emerging enteric coronaviruses in swine
title_sort microfluidic-rt-lamp chip for the point-of-care detection of emerging and re-emerging enteric coronaviruses in swine
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7234951/
https://www.ncbi.nlm.nih.gov/pubmed/32674781
http://dx.doi.org/10.1016/j.aca.2020.05.034
work_keys_str_mv AT zhouling microfluidicrtlampchipforthepointofcaredetectionofemergingandreemergingentericcoronavirusesinswine
AT chenyonghui microfluidicrtlampchipforthepointofcaredetectionofemergingandreemergingentericcoronavirusesinswine
AT fangxueen microfluidicrtlampchipforthepointofcaredetectionofemergingandreemergingentericcoronavirusesinswine
AT liuyanhong microfluidicrtlampchipforthepointofcaredetectionofemergingandreemergingentericcoronavirusesinswine
AT dumengkan microfluidicrtlampchipforthepointofcaredetectionofemergingandreemergingentericcoronavirusesinswine
AT luxiandong microfluidicrtlampchipforthepointofcaredetectionofemergingandreemergingentericcoronavirusesinswine
AT liqianniu microfluidicrtlampchipforthepointofcaredetectionofemergingandreemergingentericcoronavirusesinswine
AT sunyuan microfluidicrtlampchipforthepointofcaredetectionofemergingandreemergingentericcoronavirusesinswine
AT majingyun microfluidicrtlampchipforthepointofcaredetectionofemergingandreemergingentericcoronavirusesinswine
AT lantian microfluidicrtlampchipforthepointofcaredetectionofemergingandreemergingentericcoronavirusesinswine