Cargando…
Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study
Colistin is a polymixin antibiotic (polymixin E) that is produced by Bacillus colistinus bacteria. The aim of the present study was to develop and validate a method to quantify colistin levels in plasma using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique and th...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7234998/ https://www.ncbi.nlm.nih.gov/pubmed/32424292 http://dx.doi.org/10.1038/s41598-020-65041-w |
_version_ | 1783535881891610624 |
---|---|
author | Matar, Kamal M. Al-Refai, Batool |
author_facet | Matar, Kamal M. Al-Refai, Batool |
author_sort | Matar, Kamal M. |
collection | PubMed |
description | Colistin is a polymixin antibiotic (polymixin E) that is produced by Bacillus colistinus bacteria. The aim of the present study was to develop and validate a method to quantify colistin levels in plasma using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique and then apply it in experimental animals (rats) to investigate the pharmacokinetic profile of colistin in this species. Polymyxin B was used as an internal standard (IS) and the quantitation was carried out using ESI + interface and employing multiple reaction monitoring (MRM) mode. A mobile phase consisting of acetonitrile:water:formic acid (30:70:0.1%; v/v/v) was employed and Zorbax eclipse plus C(18) (1.8 µm, 2.1 mm i.d. x 50 mm) was the optimal column for this method and utilized at a flow rate of 0.2 mL/min. The full scan mass spectra of precursor/product ions of colistin A were at m/z 585.5 > 100.8, for colistin B at m/z 578.8 > 101 and for the IS at m/z 602.8 > 101. The lower limit of quantification (LLOQ) was 0.5 µg/mL. The method demonstrated acceptable intra-run and inter-run precision and accuracy for both colistin A and colistin B. Colistin was stable when assessed for long-term stability, freeze-thaw stability and autosampler stability. However, it was not stable when stored at room temperature. The matrix effect evaluation showed minimal or no effect. Incurred sample reanalysis findings were within acceptable ranges (<20% of the nominal concentration). The pharmacokinetic parameters of colistin were investigated in rats using the present method. The developed method for colistin demonstrates that it is rapid, sensitive, specific, accurate, precise, and reliable. |
format | Online Article Text |
id | pubmed-7234998 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-72349982020-05-26 Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study Matar, Kamal M. Al-Refai, Batool Sci Rep Article Colistin is a polymixin antibiotic (polymixin E) that is produced by Bacillus colistinus bacteria. The aim of the present study was to develop and validate a method to quantify colistin levels in plasma using high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) technique and then apply it in experimental animals (rats) to investigate the pharmacokinetic profile of colistin in this species. Polymyxin B was used as an internal standard (IS) and the quantitation was carried out using ESI + interface and employing multiple reaction monitoring (MRM) mode. A mobile phase consisting of acetonitrile:water:formic acid (30:70:0.1%; v/v/v) was employed and Zorbax eclipse plus C(18) (1.8 µm, 2.1 mm i.d. x 50 mm) was the optimal column for this method and utilized at a flow rate of 0.2 mL/min. The full scan mass spectra of precursor/product ions of colistin A were at m/z 585.5 > 100.8, for colistin B at m/z 578.8 > 101 and for the IS at m/z 602.8 > 101. The lower limit of quantification (LLOQ) was 0.5 µg/mL. The method demonstrated acceptable intra-run and inter-run precision and accuracy for both colistin A and colistin B. Colistin was stable when assessed for long-term stability, freeze-thaw stability and autosampler stability. However, it was not stable when stored at room temperature. The matrix effect evaluation showed minimal or no effect. Incurred sample reanalysis findings were within acceptable ranges (<20% of the nominal concentration). The pharmacokinetic parameters of colistin were investigated in rats using the present method. The developed method for colistin demonstrates that it is rapid, sensitive, specific, accurate, precise, and reliable. Nature Publishing Group UK 2020-05-18 /pmc/articles/PMC7234998/ /pubmed/32424292 http://dx.doi.org/10.1038/s41598-020-65041-w Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Matar, Kamal M. Al-Refai, Batool Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study |
title | Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study |
title_full | Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study |
title_fullStr | Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study |
title_full_unstemmed | Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study |
title_short | Quantification of Colistin in Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study |
title_sort | quantification of colistin in plasma by liquid chromatography-tandem mass spectrometry: application to a pharmacokinetic study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7234998/ https://www.ncbi.nlm.nih.gov/pubmed/32424292 http://dx.doi.org/10.1038/s41598-020-65041-w |
work_keys_str_mv | AT matarkamalm quantificationofcolistininplasmabyliquidchromatographytandemmassspectrometryapplicationtoapharmacokineticstudy AT alrefaibatool quantificationofcolistininplasmabyliquidchromatographytandemmassspectrometryapplicationtoapharmacokineticstudy |