Cargando…

DSC analysis and evaluation of forces released on deactivation of 0.40-mm (0.016") orthodontic thermo-activated NiTi wires: An in vitro study

Background. This study evaluated the phase transformation of NiTi orthodontic wires and forces they release on deactivation. Methods. The structural phase transformations of the following five thermo-activated nickel-titanium (NiTi) wires were evaluated using differential scanning calorimetry (DSC):...

Descripción completa

Detalles Bibliográficos
Autores principales: Sapata, Vítor Marques, Sapata, Diogo Marques, Araújo Gurgel, Julio, Medina Neto, Antônio, Ramos, Adilson Luiz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tabriz University of Medical Sciences 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7235700/
https://www.ncbi.nlm.nih.gov/pubmed/32454953
http://dx.doi.org/10.34172/joddd.2020.002
_version_ 1783536015336538112
author Sapata, Vítor Marques
Sapata, Diogo Marques
Araújo Gurgel, Julio
Medina Neto, Antônio
Ramos, Adilson Luiz
author_facet Sapata, Vítor Marques
Sapata, Diogo Marques
Araújo Gurgel, Julio
Medina Neto, Antônio
Ramos, Adilson Luiz
author_sort Sapata, Vítor Marques
collection PubMed
description Background. This study evaluated the phase transformation of NiTi orthodontic wires and forces they release on deactivation. Methods. The structural phase transformations of the following five thermo-activated nickel-titanium (NiTi) wires were evaluated using differential scanning calorimetry (DSC): Flexy Thermal Sentalloy® (GAC International), NiTi (35ºC) (Eurodonto), Thermo-Plus® (Morelli), FlexyNiTi® Flexy Thermal (35ºC) (Orthometric) and Damon® CuNiTi (35ºC) (ORMCO Corp.). The wires had a cross-section of 0.40 mm (0.016"). In addition, the forces they released were investigated using the three-point bending test. Five arches of each wire were tested using DSC (-20/80ºC at 10ºC/min), and six arches from each wire were sectioned for bending tests. The data were analyzed with ANOVA and post hoc Tukey tests. Pearson’s correlation test was performed between the results yielded by the DSC tests and those by three-point analyses (P=0.05). Results. The DSC analysis showed differences between the NiTi alloys from all the manufacturers, with no differences between the lots of the same brand. ORMCO and Orthometric wires exhibited similar TTR values in cooling (P=0.49), and statistically similar TTR values in heating (P=0.056). The three-point bending test showed different patterns in releasing forces. A correlation was found between the DSC analysis and the three-point bending test results. Conclusion. The higher the temperature transformation was, the larger was the variation of force. All the wires presented higher forces at 3-mm deflection from 155 (±12.3) to 168.1 (±8) cN. The DSC analysis and the three-point bending test showed differences between the NiTi alloys from all the manufacturers.
format Online
Article
Text
id pubmed-7235700
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Tabriz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-72357002020-05-22 DSC analysis and evaluation of forces released on deactivation of 0.40-mm (0.016") orthodontic thermo-activated NiTi wires: An in vitro study Sapata, Vítor Marques Sapata, Diogo Marques Araújo Gurgel, Julio Medina Neto, Antônio Ramos, Adilson Luiz J Dent Res Dent Clin Dent Prospects Original Article Background. This study evaluated the phase transformation of NiTi orthodontic wires and forces they release on deactivation. Methods. The structural phase transformations of the following five thermo-activated nickel-titanium (NiTi) wires were evaluated using differential scanning calorimetry (DSC): Flexy Thermal Sentalloy® (GAC International), NiTi (35ºC) (Eurodonto), Thermo-Plus® (Morelli), FlexyNiTi® Flexy Thermal (35ºC) (Orthometric) and Damon® CuNiTi (35ºC) (ORMCO Corp.). The wires had a cross-section of 0.40 mm (0.016"). In addition, the forces they released were investigated using the three-point bending test. Five arches of each wire were tested using DSC (-20/80ºC at 10ºC/min), and six arches from each wire were sectioned for bending tests. The data were analyzed with ANOVA and post hoc Tukey tests. Pearson’s correlation test was performed between the results yielded by the DSC tests and those by three-point analyses (P=0.05). Results. The DSC analysis showed differences between the NiTi alloys from all the manufacturers, with no differences between the lots of the same brand. ORMCO and Orthometric wires exhibited similar TTR values in cooling (P=0.49), and statistically similar TTR values in heating (P=0.056). The three-point bending test showed different patterns in releasing forces. A correlation was found between the DSC analysis and the three-point bending test results. Conclusion. The higher the temperature transformation was, the larger was the variation of force. All the wires presented higher forces at 3-mm deflection from 155 (±12.3) to 168.1 (±8) cN. The DSC analysis and the three-point bending test showed differences between the NiTi alloys from all the manufacturers. Tabriz University of Medical Sciences 2020 /pmc/articles/PMC7235700/ /pubmed/32454953 http://dx.doi.org/10.34172/joddd.2020.002 Text en © 2020 Marques SAPATA et al. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article published and distributed by Tabriz University of Medical Sciences under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Sapata, Vítor Marques
Sapata, Diogo Marques
Araújo Gurgel, Julio
Medina Neto, Antônio
Ramos, Adilson Luiz
DSC analysis and evaluation of forces released on deactivation of 0.40-mm (0.016") orthodontic thermo-activated NiTi wires: An in vitro study
title DSC analysis and evaluation of forces released on deactivation of 0.40-mm (0.016") orthodontic thermo-activated NiTi wires: An in vitro study
title_full DSC analysis and evaluation of forces released on deactivation of 0.40-mm (0.016") orthodontic thermo-activated NiTi wires: An in vitro study
title_fullStr DSC analysis and evaluation of forces released on deactivation of 0.40-mm (0.016") orthodontic thermo-activated NiTi wires: An in vitro study
title_full_unstemmed DSC analysis and evaluation of forces released on deactivation of 0.40-mm (0.016") orthodontic thermo-activated NiTi wires: An in vitro study
title_short DSC analysis and evaluation of forces released on deactivation of 0.40-mm (0.016") orthodontic thermo-activated NiTi wires: An in vitro study
title_sort dsc analysis and evaluation of forces released on deactivation of 0.40-mm (0.016") orthodontic thermo-activated niti wires: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7235700/
https://www.ncbi.nlm.nih.gov/pubmed/32454953
http://dx.doi.org/10.34172/joddd.2020.002
work_keys_str_mv AT sapatavitormarques dscanalysisandevaluationofforcesreleasedondeactivationof040mm0016orthodonticthermoactivatednitiwiresaninvitrostudy
AT sapatadiogomarques dscanalysisandevaluationofforcesreleasedondeactivationof040mm0016orthodonticthermoactivatednitiwiresaninvitrostudy
AT araujogurgeljulio dscanalysisandevaluationofforcesreleasedondeactivationof040mm0016orthodonticthermoactivatednitiwiresaninvitrostudy
AT medinanetoantonio dscanalysisandevaluationofforcesreleasedondeactivationof040mm0016orthodonticthermoactivatednitiwiresaninvitrostudy
AT ramosadilsonluiz dscanalysisandevaluationofforcesreleasedondeactivationof040mm0016orthodonticthermoactivatednitiwiresaninvitrostudy