Cargando…

The Performance of a Calcaneal Quantitative Ultrasound Device, CM-200, in Stratifying Osteoporosis Risk among Malaysian Population Aged 40 Years and Above

Background: Calcaneal quantitative ultrasound (QUS) is widely used in osteoporosis screening, but the cut-off values for risk stratification remain unclear. This study validates the performance of a calcaneal QUS device (CM-200) using dual-energy X-ray absorptiometry (DXA) as the reference and estab...

Descripción completa

Detalles Bibliográficos
Autores principales: Subramaniam, Shaanthana, Chan, Chin-Yi, Soelaiman, Ima Nirwana, Mohamed, Norazlina, Muhammad, Norliza, Ahmad, Fairus, Ng, Pei-Yuen, Jamil, Nor Aini, Abd Aziz, Noorazah, Chin, Kok-Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7235708/
https://www.ncbi.nlm.nih.gov/pubmed/32218298
http://dx.doi.org/10.3390/diagnostics10040178
_version_ 1783536017179934720
author Subramaniam, Shaanthana
Chan, Chin-Yi
Soelaiman, Ima Nirwana
Mohamed, Norazlina
Muhammad, Norliza
Ahmad, Fairus
Ng, Pei-Yuen
Jamil, Nor Aini
Abd Aziz, Noorazah
Chin, Kok-Yong
author_facet Subramaniam, Shaanthana
Chan, Chin-Yi
Soelaiman, Ima Nirwana
Mohamed, Norazlina
Muhammad, Norliza
Ahmad, Fairus
Ng, Pei-Yuen
Jamil, Nor Aini
Abd Aziz, Noorazah
Chin, Kok-Yong
author_sort Subramaniam, Shaanthana
collection PubMed
description Background: Calcaneal quantitative ultrasound (QUS) is widely used in osteoporosis screening, but the cut-off values for risk stratification remain unclear. This study validates the performance of a calcaneal QUS device (CM-200) using dual-energy X-ray absorptiometry (DXA) as the reference and establishes a new set of cut-off values for CM-200 in identifying subjects with osteoporosis. Methods: The bone health status of Malaysians aged ≥40 years was assessed using CM-200 and DXA. Sensitivity, specificity, area under the curve (AUC) and the optimal cut-off values for risk stratification of CM-200 were determined using receiver operating characteristic (ROC) curves and Youden’s index (J). Results: From the data of 786 subjects, CM-200 (QUS T-score <−1) showed a sensitivity of 82.1% (95% CI: 77.9–85.7%), specificity of 51.5% (95% CI: 46.5–56.6%) and AUC of 0.668 (95% CI: 0.630–0.706) in identifying subjects with suboptimal bone health (DXA T-score <−1) (p < 0.001). At QUS T-score ≤−2.5, CM-200 was ineffective in identifying subjects with osteoporosis (DXA T-score ≤−2.5) (sensitivity 14.4% (95% CI: 8.1–23.0%); specificity 96.1% (95% CI: 94.4–97.4%); AUC 0.553 (95% CI: 0.488–0.617); p > 0.05). Modified cut-off values for the QUS T-score improved the performance of CM-200 in identifying subjects with osteopenia (sensitivity 67.7% (95% CI: 62.8–72.3%); specificity 72.8% (95% CI: 68.1–77.2%); J = 0.405; AUC 0.702 (95% CI: 0.666–0.739); p < 0.001) and osteoporosis (sensitivity 79.4% (95% CI: 70.0–86.9%); specificity 61.8% (95% CI: 58.1–65.5%); J = 0.412; AUC 0.706 (95% CI: 0.654–0.758); p < 0.001). Conclusion: The modified cut-off values significantly improved the performance of CM-200 in identifying individuals with osteoporosis. Since these values are device-specific, optimization is necessary for accurate detection of individuals at risk for osteoporosis using QUS.
format Online
Article
Text
id pubmed-7235708
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72357082020-05-22 The Performance of a Calcaneal Quantitative Ultrasound Device, CM-200, in Stratifying Osteoporosis Risk among Malaysian Population Aged 40 Years and Above Subramaniam, Shaanthana Chan, Chin-Yi Soelaiman, Ima Nirwana Mohamed, Norazlina Muhammad, Norliza Ahmad, Fairus Ng, Pei-Yuen Jamil, Nor Aini Abd Aziz, Noorazah Chin, Kok-Yong Diagnostics (Basel) Article Background: Calcaneal quantitative ultrasound (QUS) is widely used in osteoporosis screening, but the cut-off values for risk stratification remain unclear. This study validates the performance of a calcaneal QUS device (CM-200) using dual-energy X-ray absorptiometry (DXA) as the reference and establishes a new set of cut-off values for CM-200 in identifying subjects with osteoporosis. Methods: The bone health status of Malaysians aged ≥40 years was assessed using CM-200 and DXA. Sensitivity, specificity, area under the curve (AUC) and the optimal cut-off values for risk stratification of CM-200 were determined using receiver operating characteristic (ROC) curves and Youden’s index (J). Results: From the data of 786 subjects, CM-200 (QUS T-score <−1) showed a sensitivity of 82.1% (95% CI: 77.9–85.7%), specificity of 51.5% (95% CI: 46.5–56.6%) and AUC of 0.668 (95% CI: 0.630–0.706) in identifying subjects with suboptimal bone health (DXA T-score <−1) (p < 0.001). At QUS T-score ≤−2.5, CM-200 was ineffective in identifying subjects with osteoporosis (DXA T-score ≤−2.5) (sensitivity 14.4% (95% CI: 8.1–23.0%); specificity 96.1% (95% CI: 94.4–97.4%); AUC 0.553 (95% CI: 0.488–0.617); p > 0.05). Modified cut-off values for the QUS T-score improved the performance of CM-200 in identifying subjects with osteopenia (sensitivity 67.7% (95% CI: 62.8–72.3%); specificity 72.8% (95% CI: 68.1–77.2%); J = 0.405; AUC 0.702 (95% CI: 0.666–0.739); p < 0.001) and osteoporosis (sensitivity 79.4% (95% CI: 70.0–86.9%); specificity 61.8% (95% CI: 58.1–65.5%); J = 0.412; AUC 0.706 (95% CI: 0.654–0.758); p < 0.001). Conclusion: The modified cut-off values significantly improved the performance of CM-200 in identifying individuals with osteoporosis. Since these values are device-specific, optimization is necessary for accurate detection of individuals at risk for osteoporosis using QUS. MDPI 2020-03-25 /pmc/articles/PMC7235708/ /pubmed/32218298 http://dx.doi.org/10.3390/diagnostics10040178 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Subramaniam, Shaanthana
Chan, Chin-Yi
Soelaiman, Ima Nirwana
Mohamed, Norazlina
Muhammad, Norliza
Ahmad, Fairus
Ng, Pei-Yuen
Jamil, Nor Aini
Abd Aziz, Noorazah
Chin, Kok-Yong
The Performance of a Calcaneal Quantitative Ultrasound Device, CM-200, in Stratifying Osteoporosis Risk among Malaysian Population Aged 40 Years and Above
title The Performance of a Calcaneal Quantitative Ultrasound Device, CM-200, in Stratifying Osteoporosis Risk among Malaysian Population Aged 40 Years and Above
title_full The Performance of a Calcaneal Quantitative Ultrasound Device, CM-200, in Stratifying Osteoporosis Risk among Malaysian Population Aged 40 Years and Above
title_fullStr The Performance of a Calcaneal Quantitative Ultrasound Device, CM-200, in Stratifying Osteoporosis Risk among Malaysian Population Aged 40 Years and Above
title_full_unstemmed The Performance of a Calcaneal Quantitative Ultrasound Device, CM-200, in Stratifying Osteoporosis Risk among Malaysian Population Aged 40 Years and Above
title_short The Performance of a Calcaneal Quantitative Ultrasound Device, CM-200, in Stratifying Osteoporosis Risk among Malaysian Population Aged 40 Years and Above
title_sort performance of a calcaneal quantitative ultrasound device, cm-200, in stratifying osteoporosis risk among malaysian population aged 40 years and above
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7235708/
https://www.ncbi.nlm.nih.gov/pubmed/32218298
http://dx.doi.org/10.3390/diagnostics10040178
work_keys_str_mv AT subramaniamshaanthana theperformanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT chanchinyi theperformanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT soelaimanimanirwana theperformanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT mohamednorazlina theperformanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT muhammadnorliza theperformanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT ahmadfairus theperformanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT ngpeiyuen theperformanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT jamilnoraini theperformanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT abdaziznoorazah theperformanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT chinkokyong theperformanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT subramaniamshaanthana performanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT chanchinyi performanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT soelaimanimanirwana performanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT mohamednorazlina performanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT muhammadnorliza performanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT ahmadfairus performanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT ngpeiyuen performanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT jamilnoraini performanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT abdaziznoorazah performanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove
AT chinkokyong performanceofacalcanealquantitativeultrasounddevicecm200instratifyingosteoporosisriskamongmalaysianpopulationaged40yearsandabove