Cargando…
Accuracy of intraoral scans in the mixed dentition: a prospective non-randomized comparative clinical trial
OBJECTIVE: In-vivo accuracy of intraoral scans of complete mixed dentitions of patients in active treatment have not yet been investigated. The aim was to test the hypothesis that dimensional differences between intraoral scans and conventional alginate impressions in the mixed dentition are clinica...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7236363/ https://www.ncbi.nlm.nih.gov/pubmed/32430023 http://dx.doi.org/10.1186/s13005-020-00222-6 |
_version_ | 1783536141919584256 |
---|---|
author | Liczmanski, Konrad Stamm, Thomas Sauerland, Cristina Blanck-Lubarsch, Moritz |
author_facet | Liczmanski, Konrad Stamm, Thomas Sauerland, Cristina Blanck-Lubarsch, Moritz |
author_sort | Liczmanski, Konrad |
collection | PubMed |
description | OBJECTIVE: In-vivo accuracy of intraoral scans of complete mixed dentitions of patients in active treatment have not yet been investigated. The aim was to test the hypothesis that dimensional differences between intraoral scans and conventional alginate impressions in the mixed dentition are clinically irrelevant. METHODS: Trial design: Prospective non-randomized comparative clinical trial. Based on sample size calculation 44 evaluable mixed dentition jaws of patients in active orthodontic treatment were included. Each patient received an alginate impression following an intraoral scan (TRIOS® Ortho). Plaster cast was fabricated and scanned with an external scanner (ATOS-SO®). Both STL datasets were analyzed with the 3D inspection and mesh processing software GOM Inspect®. Statistical analysis comprised sample size calculation, t-test as well as nonparametric tests. RESULTS: The absolute mean difference between digital plaster casts and intraoral scans is 0.022 mm ± 0.027 mm (median 0.015 mm). The obtained measurements are in the range of comparable studies on full arch permanent dentitions. Gender, the size of the jaw represented by the dentition stage and upper respectively lower jaw, as well the malocclusion have no effect on the total deviations between digital plaster casts and intraoral scans. Detectable impression errors were bubbles in fissures and marginal ridges as well as incomplete alginate flow and detachment from the tray. Detectable scanning errors were incomplete distal surface of the most distal molar. CONCLUSION: Dimensional differences between intraoral scans and conventional alginate impressions in the mixed dentition are clinically irrelevant for orthodontic purposes. In all clinical situations of active treatment in the mixed dentition, the intraoral scans are more detailed and less error-prone. |
format | Online Article Text |
id | pubmed-7236363 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-72363632020-05-29 Accuracy of intraoral scans in the mixed dentition: a prospective non-randomized comparative clinical trial Liczmanski, Konrad Stamm, Thomas Sauerland, Cristina Blanck-Lubarsch, Moritz Head Face Med Research OBJECTIVE: In-vivo accuracy of intraoral scans of complete mixed dentitions of patients in active treatment have not yet been investigated. The aim was to test the hypothesis that dimensional differences between intraoral scans and conventional alginate impressions in the mixed dentition are clinically irrelevant. METHODS: Trial design: Prospective non-randomized comparative clinical trial. Based on sample size calculation 44 evaluable mixed dentition jaws of patients in active orthodontic treatment were included. Each patient received an alginate impression following an intraoral scan (TRIOS® Ortho). Plaster cast was fabricated and scanned with an external scanner (ATOS-SO®). Both STL datasets were analyzed with the 3D inspection and mesh processing software GOM Inspect®. Statistical analysis comprised sample size calculation, t-test as well as nonparametric tests. RESULTS: The absolute mean difference between digital plaster casts and intraoral scans is 0.022 mm ± 0.027 mm (median 0.015 mm). The obtained measurements are in the range of comparable studies on full arch permanent dentitions. Gender, the size of the jaw represented by the dentition stage and upper respectively lower jaw, as well the malocclusion have no effect on the total deviations between digital plaster casts and intraoral scans. Detectable impression errors were bubbles in fissures and marginal ridges as well as incomplete alginate flow and detachment from the tray. Detectable scanning errors were incomplete distal surface of the most distal molar. CONCLUSION: Dimensional differences between intraoral scans and conventional alginate impressions in the mixed dentition are clinically irrelevant for orthodontic purposes. In all clinical situations of active treatment in the mixed dentition, the intraoral scans are more detailed and less error-prone. BioMed Central 2020-05-19 /pmc/articles/PMC7236363/ /pubmed/32430023 http://dx.doi.org/10.1186/s13005-020-00222-6 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Liczmanski, Konrad Stamm, Thomas Sauerland, Cristina Blanck-Lubarsch, Moritz Accuracy of intraoral scans in the mixed dentition: a prospective non-randomized comparative clinical trial |
title | Accuracy of intraoral scans in the mixed dentition: a prospective non-randomized comparative clinical trial |
title_full | Accuracy of intraoral scans in the mixed dentition: a prospective non-randomized comparative clinical trial |
title_fullStr | Accuracy of intraoral scans in the mixed dentition: a prospective non-randomized comparative clinical trial |
title_full_unstemmed | Accuracy of intraoral scans in the mixed dentition: a prospective non-randomized comparative clinical trial |
title_short | Accuracy of intraoral scans in the mixed dentition: a prospective non-randomized comparative clinical trial |
title_sort | accuracy of intraoral scans in the mixed dentition: a prospective non-randomized comparative clinical trial |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7236363/ https://www.ncbi.nlm.nih.gov/pubmed/32430023 http://dx.doi.org/10.1186/s13005-020-00222-6 |
work_keys_str_mv | AT liczmanskikonrad accuracyofintraoralscansinthemixeddentitionaprospectivenonrandomizedcomparativeclinicaltrial AT stammthomas accuracyofintraoralscansinthemixeddentitionaprospectivenonrandomizedcomparativeclinicaltrial AT sauerlandcristina accuracyofintraoralscansinthemixeddentitionaprospectivenonrandomizedcomparativeclinicaltrial AT blancklubarschmoritz accuracyofintraoralscansinthemixeddentitionaprospectivenonrandomizedcomparativeclinicaltrial |