Results of 198 primary total hip arthroplasties using the Delta PF-FIT system with ceramic-on-ceramic articulating surfaces with average seven years follow up

BACKGROUND: The lifetime implants is a key parameter that the surgeon should take into account at the time of the primary total hip arthroplasty (THA). The aim of this study was a clinical and radiographical evaluation of the Delta PF-FIT (LimaCorporate, Italy) THA system with ceramic-on-ceramic art...

Descripción completa

Detalles Bibliográficos
Autores principales: Fulin, Petr, Pokorny, David, Hert, Jan, Sosna, Antonin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7236923/
https://www.ncbi.nlm.nih.gov/pubmed/32429881
http://dx.doi.org/10.1186/s12891-020-03253-x
_version_ 1783536231789887488
author Fulin, Petr
Pokorny, David
Hert, Jan
Sosna, Antonin
author_facet Fulin, Petr
Pokorny, David
Hert, Jan
Sosna, Antonin
author_sort Fulin, Petr
collection PubMed
description BACKGROUND: The lifetime implants is a key parameter that the surgeon should take into account at the time of the primary total hip arthroplasty (THA). The aim of this study was a clinical and radiographical evaluation of the Delta PF-FIT (LimaCorporate, Italy) THA system with ceramic-on-ceramic articulations. We have not found a clinical or radiographical assessment of this implant in available published literature. METHODS: A total of 197 (F = 94, M = 103) primary THAs were evaluated in 163 patients with a mean follow-up of 7.7 years (range 5.1–11.2 years (SD ± 1.5)) Harris hip Score (HHS) and the Western Ontario and McMaster Universities Arthritis index (WOMAC) were used for the clinical evaluation. The statistical evaluation was processed by standard statistical methods. The study was approved by Ethic Committee of the University Hospital Motol (Reference No. EK-73/19). RESULTS: The mean HHS score was found to be 97.59 points (61–100 range with a ± 5.13 SD, preoperative HSS was 51.21, range 28–73 with a ± 4,77 SD). 186 THAs were evaluated as excellent (90–100 points), 9 THAs rated as good (80–89 points), 1 THA was rated as fair (70–79) points and 1 THA rated as poor (less than 70 points). The mean WOMAC score was 97.38 points (65–100 range with a ± 5.18 SD, preoperative was 50,12, range 27–69 with a ± 4.85 SD). We documented an overall 99.49% Kaplan-Meier survival with a mean follow-up of 7.7 years with the FIT (LimaCorporate) stem revision and any component revision as the endpoint. With the Delta PF (LimaCorporate) cup revision as the endpoint, the survival was 100%. We have not found a previously published clinical or radiographical review of this THA system, the study shows a comparison with other THA implants. CONCLUSION: Evaluation of the Delta-PF-FIT (LimaCorporate, Italy) THA system with the use of ceramic-on-ceramic BIOLOX®Delta articulation surfaces shows very good outcomes.
format Online
Article
Text
id pubmed-7236923
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-72369232020-05-27 Results of 198 primary total hip arthroplasties using the Delta PF-FIT system with ceramic-on-ceramic articulating surfaces with average seven years follow up Fulin, Petr Pokorny, David Hert, Jan Sosna, Antonin BMC Musculoskelet Disord Research Article BACKGROUND: The lifetime implants is a key parameter that the surgeon should take into account at the time of the primary total hip arthroplasty (THA). The aim of this study was a clinical and radiographical evaluation of the Delta PF-FIT (LimaCorporate, Italy) THA system with ceramic-on-ceramic articulations. We have not found a clinical or radiographical assessment of this implant in available published literature. METHODS: A total of 197 (F = 94, M = 103) primary THAs were evaluated in 163 patients with a mean follow-up of 7.7 years (range 5.1–11.2 years (SD ± 1.5)) Harris hip Score (HHS) and the Western Ontario and McMaster Universities Arthritis index (WOMAC) were used for the clinical evaluation. The statistical evaluation was processed by standard statistical methods. The study was approved by Ethic Committee of the University Hospital Motol (Reference No. EK-73/19). RESULTS: The mean HHS score was found to be 97.59 points (61–100 range with a ± 5.13 SD, preoperative HSS was 51.21, range 28–73 with a ± 4,77 SD). 186 THAs were evaluated as excellent (90–100 points), 9 THAs rated as good (80–89 points), 1 THA was rated as fair (70–79) points and 1 THA rated as poor (less than 70 points). The mean WOMAC score was 97.38 points (65–100 range with a ± 5.18 SD, preoperative was 50,12, range 27–69 with a ± 4.85 SD). We documented an overall 99.49% Kaplan-Meier survival with a mean follow-up of 7.7 years with the FIT (LimaCorporate) stem revision and any component revision as the endpoint. With the Delta PF (LimaCorporate) cup revision as the endpoint, the survival was 100%. We have not found a previously published clinical or radiographical review of this THA system, the study shows a comparison with other THA implants. CONCLUSION: Evaluation of the Delta-PF-FIT (LimaCorporate, Italy) THA system with the use of ceramic-on-ceramic BIOLOX®Delta articulation surfaces shows very good outcomes. BioMed Central 2020-05-19 /pmc/articles/PMC7236923/ /pubmed/32429881 http://dx.doi.org/10.1186/s12891-020-03253-x Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Fulin, Petr
Pokorny, David
Hert, Jan
Sosna, Antonin
Results of 198 primary total hip arthroplasties using the Delta PF-FIT system with ceramic-on-ceramic articulating surfaces with average seven years follow up
title Results of 198 primary total hip arthroplasties using the Delta PF-FIT system with ceramic-on-ceramic articulating surfaces with average seven years follow up
title_full Results of 198 primary total hip arthroplasties using the Delta PF-FIT system with ceramic-on-ceramic articulating surfaces with average seven years follow up
title_fullStr Results of 198 primary total hip arthroplasties using the Delta PF-FIT system with ceramic-on-ceramic articulating surfaces with average seven years follow up
title_full_unstemmed Results of 198 primary total hip arthroplasties using the Delta PF-FIT system with ceramic-on-ceramic articulating surfaces with average seven years follow up
title_short Results of 198 primary total hip arthroplasties using the Delta PF-FIT system with ceramic-on-ceramic articulating surfaces with average seven years follow up
title_sort results of 198 primary total hip arthroplasties using the delta pf-fit system with ceramic-on-ceramic articulating surfaces with average seven years follow up
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7236923/
https://www.ncbi.nlm.nih.gov/pubmed/32429881
http://dx.doi.org/10.1186/s12891-020-03253-x
work_keys_str_mv AT fulinpetr resultsof198primarytotalhiparthroplastiesusingthedeltapffitsystemwithceramiconceramicarticulatingsurfaceswithaveragesevenyearsfollowup
AT pokornydavid resultsof198primarytotalhiparthroplastiesusingthedeltapffitsystemwithceramiconceramicarticulatingsurfaceswithaveragesevenyearsfollowup
AT hertjan resultsof198primarytotalhiparthroplastiesusingthedeltapffitsystemwithceramiconceramicarticulatingsurfaceswithaveragesevenyearsfollowup
AT sosnaantonin resultsof198primarytotalhiparthroplastiesusingthedeltapffitsystemwithceramiconceramicarticulatingsurfaceswithaveragesevenyearsfollowup