Cargando…

Dynamic MRI for articulating joint evaluation on 1.5 T and 3.0 T scanners: setup, protocols, and real-time sequences

Dynamic magnetic resonance imaging (MRI) is a non-invasive method that can be used to increase the understanding of the pathomechanics of joints. Various types of real-time gradient echo sequences used for dynamic MRI acquisition of joints include balanced steady-state free precession sequence, radi...

Descripción completa

Detalles Bibliográficos
Autores principales: Garetier, Marc, Borotikar, Bhushan, Makki, Karim, Brochard, Sylvain, Rousseau, François, Ben Salem, Douraïed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7237553/
https://www.ncbi.nlm.nih.gov/pubmed/32430739
http://dx.doi.org/10.1186/s13244-020-00868-5
_version_ 1783536338507661312
author Garetier, Marc
Borotikar, Bhushan
Makki, Karim
Brochard, Sylvain
Rousseau, François
Ben Salem, Douraïed
author_facet Garetier, Marc
Borotikar, Bhushan
Makki, Karim
Brochard, Sylvain
Rousseau, François
Ben Salem, Douraïed
author_sort Garetier, Marc
collection PubMed
description Dynamic magnetic resonance imaging (MRI) is a non-invasive method that can be used to increase the understanding of the pathomechanics of joints. Various types of real-time gradient echo sequences used for dynamic MRI acquisition of joints include balanced steady-state free precession sequence, radiofrequency-spoiled sequence, and ultra-fast gradient echo sequence. Due to their short repetition time and echo time, these sequences provide high temporal resolution, a good signal-to-noise ratio and spatial resolution, and soft tissue contrast. The prerequisites of the evaluation of joints with dynamic MRI include suitable patient installation and optimal positioning of the joint in the coil to allow joint movement, sometimes with dedicated coil support. There are currently few recommendations in the literature regarding appropriate protocol, sequence standardizations, and diagnostic criteria for the use of real-time dynamic MRI to evaluate joints. This article summarizes the technical parameters of these sequences from various manufacturers on 1.5 T and 3.0 T MRI scanners. We have reviewed pertinent details of the patient and coil positioning for dynamic MRI of various joints. The indications and limitations of dynamic MRI of joints are discussed.
format Online
Article
Text
id pubmed-7237553
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-72375532020-05-27 Dynamic MRI for articulating joint evaluation on 1.5 T and 3.0 T scanners: setup, protocols, and real-time sequences Garetier, Marc Borotikar, Bhushan Makki, Karim Brochard, Sylvain Rousseau, François Ben Salem, Douraïed Insights Imaging Critical Review Dynamic magnetic resonance imaging (MRI) is a non-invasive method that can be used to increase the understanding of the pathomechanics of joints. Various types of real-time gradient echo sequences used for dynamic MRI acquisition of joints include balanced steady-state free precession sequence, radiofrequency-spoiled sequence, and ultra-fast gradient echo sequence. Due to their short repetition time and echo time, these sequences provide high temporal resolution, a good signal-to-noise ratio and spatial resolution, and soft tissue contrast. The prerequisites of the evaluation of joints with dynamic MRI include suitable patient installation and optimal positioning of the joint in the coil to allow joint movement, sometimes with dedicated coil support. There are currently few recommendations in the literature regarding appropriate protocol, sequence standardizations, and diagnostic criteria for the use of real-time dynamic MRI to evaluate joints. This article summarizes the technical parameters of these sequences from various manufacturers on 1.5 T and 3.0 T MRI scanners. We have reviewed pertinent details of the patient and coil positioning for dynamic MRI of various joints. The indications and limitations of dynamic MRI of joints are discussed. Springer Berlin Heidelberg 2020-05-19 /pmc/articles/PMC7237553/ /pubmed/32430739 http://dx.doi.org/10.1186/s13244-020-00868-5 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Critical Review
Garetier, Marc
Borotikar, Bhushan
Makki, Karim
Brochard, Sylvain
Rousseau, François
Ben Salem, Douraïed
Dynamic MRI for articulating joint evaluation on 1.5 T and 3.0 T scanners: setup, protocols, and real-time sequences
title Dynamic MRI for articulating joint evaluation on 1.5 T and 3.0 T scanners: setup, protocols, and real-time sequences
title_full Dynamic MRI for articulating joint evaluation on 1.5 T and 3.0 T scanners: setup, protocols, and real-time sequences
title_fullStr Dynamic MRI for articulating joint evaluation on 1.5 T and 3.0 T scanners: setup, protocols, and real-time sequences
title_full_unstemmed Dynamic MRI for articulating joint evaluation on 1.5 T and 3.0 T scanners: setup, protocols, and real-time sequences
title_short Dynamic MRI for articulating joint evaluation on 1.5 T and 3.0 T scanners: setup, protocols, and real-time sequences
title_sort dynamic mri for articulating joint evaluation on 1.5 t and 3.0 t scanners: setup, protocols, and real-time sequences
topic Critical Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7237553/
https://www.ncbi.nlm.nih.gov/pubmed/32430739
http://dx.doi.org/10.1186/s13244-020-00868-5
work_keys_str_mv AT garetiermarc dynamicmriforarticulatingjointevaluationon15tand30tscannerssetupprotocolsandrealtimesequences
AT borotikarbhushan dynamicmriforarticulatingjointevaluationon15tand30tscannerssetupprotocolsandrealtimesequences
AT makkikarim dynamicmriforarticulatingjointevaluationon15tand30tscannerssetupprotocolsandrealtimesequences
AT brochardsylvain dynamicmriforarticulatingjointevaluationon15tand30tscannerssetupprotocolsandrealtimesequences
AT rousseaufrancois dynamicmriforarticulatingjointevaluationon15tand30tscannerssetupprotocolsandrealtimesequences
AT bensalemdouraied dynamicmriforarticulatingjointevaluationon15tand30tscannerssetupprotocolsandrealtimesequences