Cargando…
Altered stresses and dynamics after single and double annuloplasty ring for aortic valve repair
OBJECTIVES: Aortic valve repair procedures for the treatment of isolated aortic valve insufficiency may be improved by stabilizing the functional aortic annulus using a double annuloplasty ring at the aortic annulus and sinotubular junction (STJ). The objective of this study was to compare the geome...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7239603/ https://www.ncbi.nlm.nih.gov/pubmed/32031602 http://dx.doi.org/10.1093/ejcts/ezaa001 |
_version_ | 1783536722311643136 |
---|---|
author | Benhassen, Leila Louise Hedensted, Jacob Hesselby Sharghbin, Mona Skov, Søren Nielsen Carlson Hanse, Lisa Tjørnild, Marcell Juan Bechsgaard, Tommy Ropcke, Diana Mathilde Nielsen, Sten Lyager Hasenkam, John Michael |
author_facet | Benhassen, Leila Louise Hedensted, Jacob Hesselby Sharghbin, Mona Skov, Søren Nielsen Carlson Hanse, Lisa Tjørnild, Marcell Juan Bechsgaard, Tommy Ropcke, Diana Mathilde Nielsen, Sten Lyager Hasenkam, John Michael |
author_sort | Benhassen, Leila Louise |
collection | PubMed |
description | OBJECTIVES: Aortic valve repair procedures for the treatment of isolated aortic valve insufficiency may be improved by stabilizing the functional aortic annulus using a double annuloplasty ring at the aortic annulus and sinotubular junction (STJ). The objective of this study was to compare the geometrical changes and aortic root stress distribution when using a single subvalvular ring and a double sub- and supravalvular ring in vivo. METHODS: Both the single- and double-ring procedures were performed successively in nine 80-kg pigs. Measurements were performed intraoperatively using sonomicrometry crystals in the aortic root to evaluate geometrical changes and annular and STJ force transducers measuring the segmental radial stress distribution. RESULTS: The total force in the STJ was significantly reduced after the double-ring procedure from 1.7 ± 0.6 to 0.04 ± 1.1 N (P = 0.001). The double-ring procedure significantly reduced the STJ area from 234.8 ± 37.6 to 147.5 ± 31.8 mm(2) (P = 0.001) and expansibility from 17 ± 6% to 8 ± 3% (P = 0.001). With the single-ring procedure, the STJ shape was circular but became more oval with the double-ring procedure. The double-ring procedure did not affect stress distribution or geometry in the aortic annulus. CONCLUSIONS: The double-ring procedure stabilized the whole aortic root by reducing radial stress distribution in the STJ more efficiently than the single-ring procedure. Both area and expansibility were reduced with the double-ring procedure. These results confirm the importance of addressing the entire functional aortic annulus for optimal aortic valve repair procedures. |
format | Online Article Text |
id | pubmed-7239603 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-72396032020-05-26 Altered stresses and dynamics after single and double annuloplasty ring for aortic valve repair Benhassen, Leila Louise Hedensted, Jacob Hesselby Sharghbin, Mona Skov, Søren Nielsen Carlson Hanse, Lisa Tjørnild, Marcell Juan Bechsgaard, Tommy Ropcke, Diana Mathilde Nielsen, Sten Lyager Hasenkam, John Michael Eur J Cardiothorac Surg Experimental OBJECTIVES: Aortic valve repair procedures for the treatment of isolated aortic valve insufficiency may be improved by stabilizing the functional aortic annulus using a double annuloplasty ring at the aortic annulus and sinotubular junction (STJ). The objective of this study was to compare the geometrical changes and aortic root stress distribution when using a single subvalvular ring and a double sub- and supravalvular ring in vivo. METHODS: Both the single- and double-ring procedures were performed successively in nine 80-kg pigs. Measurements were performed intraoperatively using sonomicrometry crystals in the aortic root to evaluate geometrical changes and annular and STJ force transducers measuring the segmental radial stress distribution. RESULTS: The total force in the STJ was significantly reduced after the double-ring procedure from 1.7 ± 0.6 to 0.04 ± 1.1 N (P = 0.001). The double-ring procedure significantly reduced the STJ area from 234.8 ± 37.6 to 147.5 ± 31.8 mm(2) (P = 0.001) and expansibility from 17 ± 6% to 8 ± 3% (P = 0.001). With the single-ring procedure, the STJ shape was circular but became more oval with the double-ring procedure. The double-ring procedure did not affect stress distribution or geometry in the aortic annulus. CONCLUSIONS: The double-ring procedure stabilized the whole aortic root by reducing radial stress distribution in the STJ more efficiently than the single-ring procedure. Both area and expansibility were reduced with the double-ring procedure. These results confirm the importance of addressing the entire functional aortic annulus for optimal aortic valve repair procedures. Oxford University Press 2020-06 2020-02-07 /pmc/articles/PMC7239603/ /pubmed/32031602 http://dx.doi.org/10.1093/ejcts/ezaa001 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Experimental Benhassen, Leila Louise Hedensted, Jacob Hesselby Sharghbin, Mona Skov, Søren Nielsen Carlson Hanse, Lisa Tjørnild, Marcell Juan Bechsgaard, Tommy Ropcke, Diana Mathilde Nielsen, Sten Lyager Hasenkam, John Michael Altered stresses and dynamics after single and double annuloplasty ring for aortic valve repair |
title | Altered stresses and dynamics after single and double annuloplasty ring for aortic valve repair |
title_full | Altered stresses and dynamics after single and double annuloplasty ring for aortic valve repair |
title_fullStr | Altered stresses and dynamics after single and double annuloplasty ring for aortic valve repair |
title_full_unstemmed | Altered stresses and dynamics after single and double annuloplasty ring for aortic valve repair |
title_short | Altered stresses and dynamics after single and double annuloplasty ring for aortic valve repair |
title_sort | altered stresses and dynamics after single and double annuloplasty ring for aortic valve repair |
topic | Experimental |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7239603/ https://www.ncbi.nlm.nih.gov/pubmed/32031602 http://dx.doi.org/10.1093/ejcts/ezaa001 |
work_keys_str_mv | AT benhassenleilalouise alteredstressesanddynamicsaftersingleanddoubleannuloplastyringforaorticvalverepair AT hedenstedjacobhesselby alteredstressesanddynamicsaftersingleanddoubleannuloplastyringforaorticvalverepair AT sharghbinmona alteredstressesanddynamicsaftersingleanddoubleannuloplastyringforaorticvalverepair AT skovsørennielsen alteredstressesanddynamicsaftersingleanddoubleannuloplastyringforaorticvalverepair AT carlsonhanselisa alteredstressesanddynamicsaftersingleanddoubleannuloplastyringforaorticvalverepair AT tjørnildmarcelljuan alteredstressesanddynamicsaftersingleanddoubleannuloplastyringforaorticvalverepair AT bechsgaardtommy alteredstressesanddynamicsaftersingleanddoubleannuloplastyringforaorticvalverepair AT ropckedianamathilde alteredstressesanddynamicsaftersingleanddoubleannuloplastyringforaorticvalverepair AT nielsenstenlyager alteredstressesanddynamicsaftersingleanddoubleannuloplastyringforaorticvalverepair AT hasenkamjohnmichael alteredstressesanddynamicsaftersingleanddoubleannuloplastyringforaorticvalverepair |