Cargando…
Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems
OBJECTIVES: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. MATERIALS AND METHODS: A total of 120 mandibular single-rooted premolars were selected. Two meth...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Conservative Dentistry
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7239674/ https://www.ncbi.nlm.nih.gov/pubmed/32483539 http://dx.doi.org/10.5395/rde.2020.45.e22 |
_version_ | 1783536736293355520 |
---|---|
author | Ramyadharshini, Tamilkumaran Anand Sherwood, Inbaraj Vigneshwar, V Shanmugham Ernest Prince, Prakasam Vaanjay, Murugadoss |
author_facet | Ramyadharshini, Tamilkumaran Anand Sherwood, Inbaraj Vigneshwar, V Shanmugham Ernest Prince, Prakasam Vaanjay, Murugadoss |
author_sort | Ramyadharshini, Tamilkumaran |
collection | PubMed |
description | OBJECTIVES: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. MATERIALS AND METHODS: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. RESULTS: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. CONCLUSIONS: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15. |
format | Online Article Text |
id | pubmed-7239674 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Korean Academy of Conservative Dentistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-72396742020-05-31 Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems Ramyadharshini, Tamilkumaran Anand Sherwood, Inbaraj Vigneshwar, V Shanmugham Ernest Prince, Prakasam Vaanjay, Murugadoss Restor Dent Endod Research Article OBJECTIVES: This study investigated the influence of glide path size and operating kinetics on the time to reach the working length and the fracture resistance of Twisted File (TF) and Endostar E3 files. MATERIALS AND METHODS: A total of 120 mandibular single-rooted premolars were selected. Two methods of kinetic motion (TF adaptive and continuous rotary motion) and file systems (TF and Endostar E3) were employed. The files were used in root canals prepared to apical glide path sizes of 15, 20, and 25. The time taken to reach the working length and the number of canals used before the instrument deformed or fractured were noted. Fractured instruments were examined with scanning electron microscopy. RESULTS: The TF system took significantly more time to reach the working length than the Endostar E3 system. Both systems required significantly more time to reach the working length at the size 15 glide path than at sizes 20 and 25. A greater number of TFs than Endostar E3 files exhibited deformation, and a higher incidence of instrument deformation was observed in adaptive than in continuous rotary motion; more deformation was also observed with the size 15 glide path. One TF was fractured while undergoing adaptive motion. CONCLUSIONS: No significant difference was observed between continuous rotary and adaptive motion. The TF system and adaptive motion were associated with a higher incidence of deformation and fracture. Apical glide path sizes of 20 and 25 required significantly less time to reach the working length than size 15. The Korean Academy of Conservative Dentistry 2020-03-05 /pmc/articles/PMC7239674/ /pubmed/32483539 http://dx.doi.org/10.5395/rde.2020.45.e22 Text en Copyright © 2020. The Korean Academy of Conservative Dentistry https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Ramyadharshini, Tamilkumaran Anand Sherwood, Inbaraj Vigneshwar, V Shanmugham Ernest Prince, Prakasam Vaanjay, Murugadoss Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems |
title | Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems |
title_full | Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems |
title_fullStr | Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems |
title_full_unstemmed | Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems |
title_short | Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems |
title_sort | influence of glide path size and operating kinetics on time to reach working length and fracture resistance of twisted file adaptive and endostar e3 nickel-titanium file systems |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7239674/ https://www.ncbi.nlm.nih.gov/pubmed/32483539 http://dx.doi.org/10.5395/rde.2020.45.e22 |
work_keys_str_mv | AT ramyadharshinitamilkumaran influenceofglidepathsizeandoperatingkineticsontimetoreachworkinglengthandfractureresistanceoftwistedfileadaptiveandendostare3nickeltitaniumfilesystems AT anandsherwoodinbaraj influenceofglidepathsizeandoperatingkineticsontimetoreachworkinglengthandfractureresistanceoftwistedfileadaptiveandendostare3nickeltitaniumfilesystems AT vigneshwarvshanmugham influenceofglidepathsizeandoperatingkineticsontimetoreachworkinglengthandfractureresistanceoftwistedfileadaptiveandendostare3nickeltitaniumfilesystems AT ernestprinceprakasam influenceofglidepathsizeandoperatingkineticsontimetoreachworkinglengthandfractureresistanceoftwistedfileadaptiveandendostare3nickeltitaniumfilesystems AT vaanjaymurugadoss influenceofglidepathsizeandoperatingkineticsontimetoreachworkinglengthandfractureresistanceoftwistedfileadaptiveandendostare3nickeltitaniumfilesystems |