Cargando…

Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review

OBJECTIVES: This systematic review evaluated the influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium (NiTi) instruments. MATERIALS AND METHODS: A systematic search without restrictions was conducted in the following electronic databases: P...

Descripción completa

Detalles Bibliográficos
Autores principales: Silva, Emmanuel João Nogueira Leal, Zanon, Mayara, Hecksher, Fernanda, Belladonna, Felipe Gonçalves, de Vasconcelos, Rafaela Andrade, Fidalgo, Tatiana Kelly da Silva
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Conservative Dentistry 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7239677/
https://www.ncbi.nlm.nih.gov/pubmed/32483542
http://dx.doi.org/10.5395/rde.2020.45.e25
_version_ 1783536737015824384
author Silva, Emmanuel João Nogueira Leal
Zanon, Mayara
Hecksher, Fernanda
Belladonna, Felipe Gonçalves
de Vasconcelos, Rafaela Andrade
Fidalgo, Tatiana Kelly da Silva
author_facet Silva, Emmanuel João Nogueira Leal
Zanon, Mayara
Hecksher, Fernanda
Belladonna, Felipe Gonçalves
de Vasconcelos, Rafaela Andrade
Fidalgo, Tatiana Kelly da Silva
author_sort Silva, Emmanuel João Nogueira Leal
collection PubMed
description OBJECTIVES: This systematic review evaluated the influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium (NiTi) instruments. MATERIALS AND METHODS: A systematic search without restrictions was conducted in the following electronic databases: PubMed, Scopus, Web of Science, ScienceDirect, Cochrane, and Open Grey. The hand search was also performed in the main endodontic journals. The eligible studies were submitted to the methodological assessment and data extraction. RESULTS: From 203 abstracts, a total of 10 articles matched the eligible criteria. After reading the full articles, 2 were excluded because of the absence of the heat-treated instruments in the experimental design and 3 due to the lack of a control group using heat-treated instruments without autoclave sterilization. From the 5 included studies, 1 presented a low risk of bias, 3 presented moderate and 1 high risk. It was observed heterogeneous findings in the included studies, with autoclave sterilization cycles increasing, decreasing or not affecting the cyclic fatigue life of heat-treated NiTi instruments. However, the retrieved studies evaluating the cyclic fatigue resistance of endodontic instruments presented different protocols and assessing outcomes, this variability makes the findings less comparable within and also between groups and preclude the establishment of an unbiased scientific evidence base. CONCLUSIONS: Considering the little scientific evidence and considerable risk of bias, it is still possible to conclude that autoclave sterilization procedures appear to influence the cyclic fatigue resistance of heat-treated NiTi instruments.
format Online
Article
Text
id pubmed-7239677
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Academy of Conservative Dentistry
record_format MEDLINE/PubMed
spelling pubmed-72396772020-05-31 Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review Silva, Emmanuel João Nogueira Leal Zanon, Mayara Hecksher, Fernanda Belladonna, Felipe Gonçalves de Vasconcelos, Rafaela Andrade Fidalgo, Tatiana Kelly da Silva Restor Dent Endod Research Article OBJECTIVES: This systematic review evaluated the influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium (NiTi) instruments. MATERIALS AND METHODS: A systematic search without restrictions was conducted in the following electronic databases: PubMed, Scopus, Web of Science, ScienceDirect, Cochrane, and Open Grey. The hand search was also performed in the main endodontic journals. The eligible studies were submitted to the methodological assessment and data extraction. RESULTS: From 203 abstracts, a total of 10 articles matched the eligible criteria. After reading the full articles, 2 were excluded because of the absence of the heat-treated instruments in the experimental design and 3 due to the lack of a control group using heat-treated instruments without autoclave sterilization. From the 5 included studies, 1 presented a low risk of bias, 3 presented moderate and 1 high risk. It was observed heterogeneous findings in the included studies, with autoclave sterilization cycles increasing, decreasing or not affecting the cyclic fatigue life of heat-treated NiTi instruments. However, the retrieved studies evaluating the cyclic fatigue resistance of endodontic instruments presented different protocols and assessing outcomes, this variability makes the findings less comparable within and also between groups and preclude the establishment of an unbiased scientific evidence base. CONCLUSIONS: Considering the little scientific evidence and considerable risk of bias, it is still possible to conclude that autoclave sterilization procedures appear to influence the cyclic fatigue resistance of heat-treated NiTi instruments. The Korean Academy of Conservative Dentistry 2020-03-31 /pmc/articles/PMC7239677/ /pubmed/32483542 http://dx.doi.org/10.5395/rde.2020.45.e25 Text en Copyright © 2020. The Korean Academy of Conservative Dentistry https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Silva, Emmanuel João Nogueira Leal
Zanon, Mayara
Hecksher, Fernanda
Belladonna, Felipe Gonçalves
de Vasconcelos, Rafaela Andrade
Fidalgo, Tatiana Kelly da Silva
Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review
title Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review
title_full Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review
title_fullStr Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review
title_full_unstemmed Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review
title_short Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review
title_sort influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7239677/
https://www.ncbi.nlm.nih.gov/pubmed/32483542
http://dx.doi.org/10.5395/rde.2020.45.e25
work_keys_str_mv AT silvaemmanueljoaonogueiraleal influenceofautoclavesterilizationproceduresonthecyclicfatigueresistanceofheattreatednickeltitaniuminstrumentsasystematicreview
AT zanonmayara influenceofautoclavesterilizationproceduresonthecyclicfatigueresistanceofheattreatednickeltitaniuminstrumentsasystematicreview
AT hecksherfernanda influenceofautoclavesterilizationproceduresonthecyclicfatigueresistanceofheattreatednickeltitaniuminstrumentsasystematicreview
AT belladonnafelipegoncalves influenceofautoclavesterilizationproceduresonthecyclicfatigueresistanceofheattreatednickeltitaniuminstrumentsasystematicreview
AT devasconcelosrafaelaandrade influenceofautoclavesterilizationproceduresonthecyclicfatigueresistanceofheattreatednickeltitaniuminstrumentsasystematicreview
AT fidalgotatianakellydasilva influenceofautoclavesterilizationproceduresonthecyclicfatigueresistanceofheattreatednickeltitaniuminstrumentsasystematicreview