Cargando…

Fear of the Relapse: Effect of Composite Type on Adhesion Efficacy of Upper and Lower Orthodontic Fixed Retainers: In Vitro Investigation and Randomized Clinical Trial

The aim of this laboratory and clinical study is to determine the reliability of the flowable nanocomposite Filtek Supreme XTE (FL) for the adhesion of orthodontic retainers, compared to highly filled orthodontic resin Transbond XT (XT). Portions of a round section multistranded wire (Ortosmail Krug...

Descripción completa

Detalles Bibliográficos
Autores principales: Scribante, Andrea, Gallo, Simone, Turcato, Benedetta, Trovati, Federico, Gandini, Paola, Sfondrini, Maria Francesca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7240513/
https://www.ncbi.nlm.nih.gov/pubmed/32326201
http://dx.doi.org/10.3390/polym12040963
_version_ 1783536900772986880
author Scribante, Andrea
Gallo, Simone
Turcato, Benedetta
Trovati, Federico
Gandini, Paola
Sfondrini, Maria Francesca
author_facet Scribante, Andrea
Gallo, Simone
Turcato, Benedetta
Trovati, Federico
Gandini, Paola
Sfondrini, Maria Francesca
author_sort Scribante, Andrea
collection PubMed
description The aim of this laboratory and clinical study is to determine the reliability of the flowable nanocomposite Filtek Supreme XTE (FL) for the adhesion of orthodontic retainers, compared to highly filled orthodontic resin Transbond XT (XT). Portions of a round section multistranded wire (Ortosmail Krugg) were bonded to 40 bovine incisors with Scotchbond Universal in total-etch modality. For group one (XT, 20 samples), the orthodontic resin was used, whereas in group two (FL, 20 samples), the flowable one. Specimens were placed into a universal testing machine which applied a shear force on retainers with a crosshead speed of one/minute. Shear bond strength (SBS) and adhesive remnant index (ARI) scores were calculated. In the clinical trial, 100 patients requiring a canine-to-canine palatal and lingual retainer were randomly divided into two groups, according to the resin used for bonding procedure: the orthodontic in group one (XT, 50 participants) and the flowable in group two (FL, 50 participants). Monthly visits were carried out over a 24-month follow up to assess any detachment occurring on teeth of both arches. All data were submitted to statistical analysis. In vitro, FL reported a significant lower mean SBS, whereas no significant differences in ARI were reported between the two groups which both showed a major frequency of scores “1” and “2”. At the end of the 24-month follow up, FL reported significantly higher failure rates in both arches besides a significantly lower survival rate starting from the sixth month after retainers bonding. According to the results assessed in vitro and clinically, XT would be preferable to FL when performing retainers bonding procedure.
format Online
Article
Text
id pubmed-7240513
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-72405132020-06-11 Fear of the Relapse: Effect of Composite Type on Adhesion Efficacy of Upper and Lower Orthodontic Fixed Retainers: In Vitro Investigation and Randomized Clinical Trial Scribante, Andrea Gallo, Simone Turcato, Benedetta Trovati, Federico Gandini, Paola Sfondrini, Maria Francesca Polymers (Basel) Article The aim of this laboratory and clinical study is to determine the reliability of the flowable nanocomposite Filtek Supreme XTE (FL) for the adhesion of orthodontic retainers, compared to highly filled orthodontic resin Transbond XT (XT). Portions of a round section multistranded wire (Ortosmail Krugg) were bonded to 40 bovine incisors with Scotchbond Universal in total-etch modality. For group one (XT, 20 samples), the orthodontic resin was used, whereas in group two (FL, 20 samples), the flowable one. Specimens were placed into a universal testing machine which applied a shear force on retainers with a crosshead speed of one/minute. Shear bond strength (SBS) and adhesive remnant index (ARI) scores were calculated. In the clinical trial, 100 patients requiring a canine-to-canine palatal and lingual retainer were randomly divided into two groups, according to the resin used for bonding procedure: the orthodontic in group one (XT, 50 participants) and the flowable in group two (FL, 50 participants). Monthly visits were carried out over a 24-month follow up to assess any detachment occurring on teeth of both arches. All data were submitted to statistical analysis. In vitro, FL reported a significant lower mean SBS, whereas no significant differences in ARI were reported between the two groups which both showed a major frequency of scores “1” and “2”. At the end of the 24-month follow up, FL reported significantly higher failure rates in both arches besides a significantly lower survival rate starting from the sixth month after retainers bonding. According to the results assessed in vitro and clinically, XT would be preferable to FL when performing retainers bonding procedure. MDPI 2020-04-21 /pmc/articles/PMC7240513/ /pubmed/32326201 http://dx.doi.org/10.3390/polym12040963 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Scribante, Andrea
Gallo, Simone
Turcato, Benedetta
Trovati, Federico
Gandini, Paola
Sfondrini, Maria Francesca
Fear of the Relapse: Effect of Composite Type on Adhesion Efficacy of Upper and Lower Orthodontic Fixed Retainers: In Vitro Investigation and Randomized Clinical Trial
title Fear of the Relapse: Effect of Composite Type on Adhesion Efficacy of Upper and Lower Orthodontic Fixed Retainers: In Vitro Investigation and Randomized Clinical Trial
title_full Fear of the Relapse: Effect of Composite Type on Adhesion Efficacy of Upper and Lower Orthodontic Fixed Retainers: In Vitro Investigation and Randomized Clinical Trial
title_fullStr Fear of the Relapse: Effect of Composite Type on Adhesion Efficacy of Upper and Lower Orthodontic Fixed Retainers: In Vitro Investigation and Randomized Clinical Trial
title_full_unstemmed Fear of the Relapse: Effect of Composite Type on Adhesion Efficacy of Upper and Lower Orthodontic Fixed Retainers: In Vitro Investigation and Randomized Clinical Trial
title_short Fear of the Relapse: Effect of Composite Type on Adhesion Efficacy of Upper and Lower Orthodontic Fixed Retainers: In Vitro Investigation and Randomized Clinical Trial
title_sort fear of the relapse: effect of composite type on adhesion efficacy of upper and lower orthodontic fixed retainers: in vitro investigation and randomized clinical trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7240513/
https://www.ncbi.nlm.nih.gov/pubmed/32326201
http://dx.doi.org/10.3390/polym12040963
work_keys_str_mv AT scribanteandrea fearoftherelapseeffectofcompositetypeonadhesionefficacyofupperandlowerorthodonticfixedretainersinvitroinvestigationandrandomizedclinicaltrial
AT gallosimone fearoftherelapseeffectofcompositetypeonadhesionefficacyofupperandlowerorthodonticfixedretainersinvitroinvestigationandrandomizedclinicaltrial
AT turcatobenedetta fearoftherelapseeffectofcompositetypeonadhesionefficacyofupperandlowerorthodonticfixedretainersinvitroinvestigationandrandomizedclinicaltrial
AT trovatifederico fearoftherelapseeffectofcompositetypeonadhesionefficacyofupperandlowerorthodonticfixedretainersinvitroinvestigationandrandomizedclinicaltrial
AT gandinipaola fearoftherelapseeffectofcompositetypeonadhesionefficacyofupperandlowerorthodonticfixedretainersinvitroinvestigationandrandomizedclinicaltrial
AT sfondrinimariafrancesca fearoftherelapseeffectofcompositetypeonadhesionefficacyofupperandlowerorthodonticfixedretainersinvitroinvestigationandrandomizedclinicaltrial